Accurate body temperature measurement is essential for monitoring and managing safety during outdoor activities. Physical activities are an essential consideration for public health, with sports taking up an important proportion of these. Athletes' performances can be directly affected by body temperature fluctuations, with overheating or hypothermia posing serious health risks.
View Article and Find Full Text PDFThe reliable monitoring of heart rate during intense exercise is imperative to effectively manage training loads while providing insights from a healthcare perspective. However, current technologies perform poorly in contact sports settings. This study aims to evaluate the best approach for heart rate tracking using photoplethysmography sensors embedded into an instrumented mouthguard (iMG).
View Article and Find Full Text PDFTechnological advancements are enabling new applications within biomedical engineering. As a connection point between the outer environment and the human system, the oral cavity offers unique opportunities for sensing technologies. This paper systematically reviews the performance of measurement systems tested in the human oral cavity.
View Article and Find Full Text PDFObjective: This study aimed to determine the steady-state errors of oral-based temperature sensors, that are embedded in mouthguards, using a robust assessment process.
Materials And Methods: Four electronic boards with temperature sensors were encapsulated in mouthguards made from ethylene-vinyl acetate (EVA). The error and time to reach steady-state temperature were determined using a thermostatic water bath during three different conditions (34, 38.