Publications by authors named "Leonardo Goncalves Cunha"

Purpose: To evaluate the fracture resistance (FR), and push-out bond strengths (BS) of custom-made CAD/CAM post-and-cores manufactured with different esthetic materials.

Methods: 90 single-rooted extracted teeth were selected, endodontically treated and prepared to receive the posts. The specimens were randomly divided into three equal groups according to the material: hybrid ceramic Vita Enamic (HC); nano-ceramic resin composite Lava Ultimate (RC); and experimental epoxy-resin reinforced by glass-fiber (FG).

View Article and Find Full Text PDF

Objective: The objective of this study was to evaluate the diametral tensile strength (DTS) and Knoop hardness (KH) of direct (Filtek Z350-3M/ESPE and Charisma-Heraeus Kulzer) and indirect composites (Sinfony-3M/ESPE and Signum-Heraeus Kulzer) kept in storage for two periods of time, 24 hours and 10 months, in distilled water.

Methods: Twenty-five specimens of each material were prepared. DTS (n=10) was tested using a universal testing machine (Versat, model 2000) at a crosshead speed of 1.

View Article and Find Full Text PDF

Purpose: To evaluate the implant-abutment interface area and the abutment screw loosening value when diamondlike carbon (DLC)-coated or titanium screws were used before and after cyclic loading.

Materials And Methods: Thirty-six implants were divided into four groups according to the type of connection (external hexagon [EH] or internal hexagon [IH]) and the type of abutment screw (with [EHD/IHD] or without [EHT/IHT] DLC coating). The implants were placed in epoxy resin-glass fiber composite, and crowns cast in a metal alloy were screwed to the implants.

View Article and Find Full Text PDF

The aim of the present study was to evaluate the influence of curing methods and composite volumes on the marginal and internal adaptation of composite restoratives. Two cavities with different volumes (Lower volume: 12.6 mm(3); Higher volume: 24.

View Article and Find Full Text PDF

During clinical practice, when performing prosthetic rehabilitation with single crowns, improper reproduction of the dental contour by the dental laboratory is a common occurrence. Therefore, the present study evaluated the fidelity of the reproduction of the buccal contour in an upper left canine performed by three Dental Prosthesis Technicians (DPT) using the indirect laminate veneer technique. First, the DPTs confected the veneers based on a model obtained from the upper arch of a dental dummy, containing a replica of an upper left canine with a prosthetic preparation for a laminate veneer.

View Article and Find Full Text PDF

Purpose: To evaluate the influence of five curing methods on contraction stress, stress rate, and degree of conversion (DC) of a composite and on bond strength of composite restoratives.

Methods: For the stress test, composite was applied between two 5-mm diameter glass rods, mounted in a servohydraulic machine. Stress rates were calculated as the change in stress vs.

View Article and Find Full Text PDF

Purpose: Symmetry is one of the factors that contributes to facial harmony, and in oral rehabilitation it determines the success of esthetic treatment. Therefore, the aim of the present study was to analyze the axial symmetry between the bipupillar midline and maxillary central incisors midline of 102 dental students (both genders) distributed across five Brazilian dental schools.

Materials And Methods: Students with no teeth missing and who had never been subjected to any dental treatment were selected.

View Article and Find Full Text PDF

This study verified the influence of curing methods and light sources on contraction stress, stress rate and degree of conversion (DC) of a restorative composite at two C-factor (CF) levels. For the stress test, composite (0.84 mm thick) was applied between two glass rods 5-mm in diameter mounted in a servohydraulic testing machine.

View Article and Find Full Text PDF

The aim of this study was to evaluate the effect of different curing methods on the stress generated by the polymerization shrinkage of a restorative composite in two moments: immediately after light exposure and after 5 min. Photoactivation was performed using two different light sources: (1) xenon plasma arc (PAC) light (1,500 mW/cm2 - 3s) and (2) a quartz-tungsten-halogen (QTH) light with three light-curing regimens: continuous exposure (40 s at 800 mW/cm2 - CL); soft-start (10 s at 150 mW/cm2 and 30 s at 800 mW/cm2 - SS) and intermittent light [cycles of 4 s (2 s with light on at 600 mW/cm2 and 2 s of light off), for 80s - IL]. The composite resin was applied between two 5-mm diameter metallic rods, mounted in a servohydraulic machine.

View Article and Find Full Text PDF

Objective: Modulated curing methods could lead to a higher probability of bond preservation. Therefore, the aim of this study was to evaluate the effect of 7 curing methods on bond strength of composite resin restorations.

Method And Materials: Seventy bovine incisors were selected.

View Article and Find Full Text PDF

Objectives: Verify the influence of curing methods on contraction stress, stress rate, and degree of conversion (DC) of a restorative composite and on bond strength of composite restoratives.

Methods: For the stress test, composite (0.84 mm thick) was applied between two 5-mm diameter glass rods, mounted in a servohydraulic machine.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the influence of resin liners on the marginal adaptation to dentin of resin composite restorations photoactivated by a conventional quartz-tungsten halogen lamp (QTH), light emitting diodes (LED), and a plasma arc light (PAC).

Materials And Methods: The buccal surfaces of 120 bovine incisors were ground until a flat dentin area was obtained. A circular cavity (4 mm in diameter x 1.

View Article and Find Full Text PDF

Objective: This study evaluated the relationship between bond strength and marginal and internal adaptation of composite restorations photocured using different methods with a quartz-tungsten-halogen light.

Material And Methods: A push-out test was performed to evaluate bond strength of conical restorations in 50 bovine incisors. To evaluate marginal (external) and internal restoration adaptation, 50 circular all-enamel margin preparations were done in bovine incisors.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate and compare marginal adaptation of composite restorations assessed by a dye staining method and by scanning electron microscopy (SEM) analysis.

Material And Methods: Twenty bovine incisors were selected and ground flat to expose dentin. Two cylindrical cavities were prepared on the central area of flattened surfaces.

View Article and Find Full Text PDF

Purpose: This study was undertaken to evaluate the effect of three different photoactivation methods on the polymerization shrinkage stress of a resin composite using different resin liners.

Materials And Methods: Three photoactivation methods using a quartz-tungsten-halogen light were evaluated: continuous light, soft start, and intermittent light. Three lining groups were tested: one or three coats of adhesive, and flowable composite.

View Article and Find Full Text PDF

The aim of this study was to evaluate the effect of photoactivation methods, resin liners, and the association of these techniques on the marginal adaptation of composite restorations. One-hundred-and-twenty bovine incisors were selected. A circular cavity was prepared in a flat dentin area on the buccal surface and the Scotchbond Multi Purpose system was applied.

View Article and Find Full Text PDF

The aim of this study was to evaluate the surface roughness of two Ormocer-based resin composites before and after mechanical toothbrushing. The study compared the brands Admira and Definite with composites based on conventional monomer systems (Bis-GMA, Bis-EMA, UEDMA e TEGDMA), Z250 and A110. Eight samples of each material with 4mm in diameter and 2mm in height were prepared using a metallic mold.

View Article and Find Full Text PDF

This study verified the polymerization depth of the composite Z100 (3M Dental Products) by Knoop Hardness test using four photoactivation methods. Twenty cylindrical specimens (5 mm in diameter by 5 mm in height) were prepared in a metallic mold and photoactivated by one of the four methods: continuous light (520 mW/cm2 for 40 seconds); stepped light (150 mW/cm2 for 10 seconds followed by 520 mW/cm2 for 30 seconds); intermittent light (cycle of 1 second, 1/2 second with the light on and 1/2 second with the light off for 60 seconds at 520 mW/cm2) and Xenon plasma are (1370 mW/cm2 for 3 seconds). Knoop hardness measurements were obtained on the surface, at the depths of 1.

View Article and Find Full Text PDF