Publications by authors named "Leonardo E Rodrigues Filho"

Purpose: To determine the degree of conversion (DC), physicochemical properties, and microshear bond strength (µSBS) of experimental self-adhesive resin cements (SARCs) to dentin and yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramic.

Materials And Methods: Dual-curing cements were formulated with UDMA, HEMA, bis-GMA, and TEG-DMA as the organic matrix. 2MP (bis 2-(methacryloyloxy)-ethyl-phosphate) and GDMAP (1,3-glycerol dimethacrylate phosphate) were added to impart self-adhesive characteristics.

View Article and Find Full Text PDF

Objective: To determine the influence of benzenesulfinic acid sodium salt 98% (BAS) and the activation mode on the polymerization behavior of experimental self-adhesive resin cements (SARCs) formulated with distinct self-etch methacrylates.

Materials And Methods: Three catalyst-pastes using different self-etch methacrylates (2MP - bis 2-(methacryloyloxy) ethyl phosphate; 4META - 4-methacryloxyethyl trimellitic acid anhydride; and GDMAP - 1,3-glycerol dimethacrylate phosphate) and four base-pastes were formulated from the incorporation of different amounts of BAS associated to N-N-dihydroxyethyl-p-toluidine (DHPT). BAS/DHPT ratios were blended respectively based on the following final weight (wt%): control (0.

View Article and Find Full Text PDF

This study evaluated the influence of formulation and thermal treatment on the degree of conversion, fracture toughness, flexural strength, and elastic modulus of experimental composites. Six composites were analyzed at BisGMA : TEGDMA molar ratios of 1 : 1 and 7 : 3 with filler at 30, 50, and 70 wt%. The degree of conversion was analyzed by Fourier transform infrared spectroscopy, fracture toughness was measured using the single-edge notched beam, and flexural strength and elastic modulus were measured with the 3-point bend test.

View Article and Find Full Text PDF

The aim of this in vitro study was to evaluate the pH effect of doxycycline solutions on the immediate dentin bond strength of a total-etch adhesive system. Twenty human molars were divided into 4 groups (n = 5) after acid etching according to surface treatment: 10% acidic doxycycline, 10% neutral doxycycline, 2% chlorhexidine, and control. Composite resin blocks were made and subjected to microtensile testing.

View Article and Find Full Text PDF

The aim of the present study was to evaluate the tensile strength, elongation, microhardness, microstructure and fracture pattern of various metal ceramic alloys cast under different casting conditions. Two Ni-Cr alloys, Co-Cr and Pd-Ag were used. The casting conditions were as follows: electromagnetic induction under argon atmosphere, vacuum, using blowtorch without atmosphere control.

View Article and Find Full Text PDF

Objectives: To purpose a method for predicting the shrinkage stress development in the adhesive layer of resin-composite cylinders that shrink bonded to a single flat surface, by measuring the deflection of a glass coverslip caused by the shrinkage of the bonded cylinders. The correlation between the volume of the bonded resin-composite and the stress-peak was also investigated.

Methods: A glass coverslip deflection caused by the shrinkage of a bonded resin-composite cylinder (diameter: d=8 mm, 4 mm, or 2 mm, height: h=4 mm, 2 mm, 1 mm, or 0.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the flexural strength of a direct composite, for indirect application, that received heat treatment, with or without investment. One indirect composite was used for comparison. For determination of the heat treatment temperature, thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) were performed, considering the initial weight loss temperature and glass transition temperature (Tg).

View Article and Find Full Text PDF

Provision of an inert gas atmosphere with high-purity argon gas is recommended for preventing titanium castings from contamination although the effects of the level of argon purity on the mechanical properties and the clinical performance of Ti castings have not yet been investigated. The purpose of this study was to evaluate the effect of argon purity on the mechanical properties and microstructure of commercially pure (cp) Ti and Ti-6Al-4V alloys. The castings were made using either high-purity and/or industrial argon gas.

View Article and Find Full Text PDF

Objective: To assess the ability of two chemical and a microbiological methods to produce dentine caries lesions resembling naturally developed dentine caries lesions.

Design: Forty sound second primary molars were divided into four experimental groups according to the method to produce artificial caries lesions: (1) sound (negative control); (2) acidified gel; (3) pH-cycling; and (4) microbiological, all for 14 days. Ten second primary molars presenting natural dentine caries lesions comprised the (5) positive control group.

View Article and Find Full Text PDF

The aim of this study was to verify the influence of an experimental heat treatment (170 masculineC/10 min) using a casting furnace on the mechanical properties (hardness and flexural strength) of 2 commercial direct resin composites (TPH Spectrum and Filtek P60) compared to a commercial indirect resin system (BelleGlass). Heat treatment temperature was determined after thermal characterization by thermogravimetry (TG) and differential scanning calorimetry (DSC). Data was analyzed by ANOVA and Tukey's test at 5% significance level.

View Article and Find Full Text PDF

This study evaluated the influence of adhesive layer thickness (ADL) on the resin-dentin bond strength of two adhesive systems (AS) after thermal and mechanical loading (TML). A flat superficial dentin surface was exposed with 600-grit SiC paper on 40 molars. After primer application, the adhesive layer of Scotchbond Multipurpose (SBMP) or Clearfil SE Bond (CSEB) was applied in one or two layers to a delimited area (52 mm2) and resin blocks (Filtek Z250) were built incrementally.

View Article and Find Full Text PDF

Purpose: As clinical diagnosis of secondary caries is the most common reason for restoration replacement, fluoride-releasing restorative materials have been developed to address this problem. The purposes of this study were to verify demineralization inhibition produced by 5 restorative materials submitted to two methods of in vitro cariogenic challenge and verify whether these methods influence material behavior by means of polarized light microscopy and microhardness.

Methods: Class V cavities were prepared on buccal surfaces of 100 extracted primary molars and randomly restored with 1 of the 4 fluoride-releasing materials, Fuji IX, Vitremer, Dyract, Tetric Ceram, and Filtek Z250 as control material (N=10).

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the in vitro influence of aging treatments on the microtensile bond strength of 2-step total-etch and self-etch adhesive systems to primary dentin.

Methods: Class I cavities (4 mm x 4 mm x 2 mm) were prepared in 80 extracted human primary molars divided into 8 groups (N=5) per adhesive system: (1) Single Bond (SI); and (2) Clearfil SE Bond (SE). Restored teeth were exposed to individual and combined aging treatments: (1) thermal (2,000 x at 5-55 degrees C; T); (2) mechanical load (100,000 x 80 N; M); (3) pH (mineralizing/demineralizing solutions; pH); and (4) control (24-hour water storage; C).

View Article and Find Full Text PDF

The purpose of this in vitro study was to analyze the residual dentinal surfaces following caries removal using rotatory instruments and two chemomechanical methods (Papacárie and Carisolv), by scanning electron microscopy (SEM). Thirty primary incisors were divided into three groups, according to the caries removal method used, and their residual dentin was examined under SEM (15). After caries removal, 15 of these teeth were restored with Single Bond (3M) adhesive system and Z100 Filtek composite resin (3M).

View Article and Find Full Text PDF

Canine tooth fracture is common in dogs. Application of an esthetic and durable restoration may be challenging in veterinary dental practice. This study used traditional human dental laboratory methods to evaluate fracture strength of intact dog canine teeth and fractured teeth that had been restored by reattachment of the tooth fragment.

View Article and Find Full Text PDF

The aim of this in vitro study was to assess the remaining dentinal surface after carious tooth tissue removal with a low speed conventional bur and two chemomechanical methods, (Papacárie and Carisolv), using the microhardness test. It was concluded that the hardness of the remaining dentin after carious tissue removal was lower than that obtained on healthy dentin, without significance between the different means of carious tissue removal (p<0.05).

View Article and Find Full Text PDF

Purpose: This study measured: 1) the interfacial dentin gap formation (IGW) of 2 etch & rinse and 3 self-etch systems with different degrees of acidity and determined the correlation between the smear layer thickness and interfacial gap formation after 1 day and 6 months water storage; 2) the hybrid layer thickness (HLT) produced by the adhesives applied under different smear layer thicknesses.

Methods And Materials: Three self-etch adhesives, a mild (Clearfil SE Bond; SE), a moderate (Optibond Solo Plus Self-Etch Primer; SO) and a strong (Tyrian Self Priming Etchant + One Step Plus; TY), and 2 etch & rinse systems (Single Bond; SB and Scotchbond Multi-Purpose Plus; SBMP) were studied. After flat grinding of the occlusal surfaces, 30 molars were sectioned longitudinally in 2 halves.

View Article and Find Full Text PDF

The present study evaluated the flexural strength of three composite resins recommended for direct esthetic restorations: a polyacid modified composite (Dyract AP), a unimodal composite resin (Filtek Z250) and a hybrid composite resin (Point 4). The variation factors, apart from the type of composite resin, were the light activation method and the water storage period. The composite resins were light-cured in continuous mode (40 s, 500 mW/cm2) or in ramp mode (0-800 mW/cm2 for 10 s followed by 30 s at 800 mW/cm2) and stored for 24 hours or 30 days in distilled water at 37 degrees C.

View Article and Find Full Text PDF

This study evaluated the microhardness of Ni-Cr alloys used in fixed prosthodontics after casting under different conditions. The casting conditions were: (1-flame/air torch) flame made of a gas/oxygen mixture and centrifugal casting machine in a non-controlled casting environment; (2-induction/argon) electromagnetic induction in an environment controlled with argon; (3-induction/vacuum) electromagnetic induction in a vacuum environment; (4-induction/air) electromagnetic induction in a non-controlled casting environment. The 3 alloys used were Ni-Cr-Mo-Ti, Ni-Cr-Mo-Be, and Ni-Cr-Mo-Nb.

View Article and Find Full Text PDF

The handling of vinyl polysiloxane (addition silicone) impression putties with latex gloves is said to interfere with the setting of these impression materials. The aim of this study is to evaluate the effect of handling techniques on the setting of vinyl polysiloxane impression putties using several types of gloves. The setting of these materials was evaluated by means of an elasticimeter.

View Article and Find Full Text PDF

The purpose of the present study was to evaluate the bond strength of four adhesive systems to dentin. Twelve human third molars had their occlusal enamel removed in order to expose a flat dentinal surface, on which the adhesive procedures were carried out. The teeth were divided into four groups, according to the employed adhesive system and composite resin: Group 1 - Single Bond + P60 (SB); Group 2 - Bond 1 + Surefil (B1); Group 3 - Prime Bond NT + Alert (NT); and Group 4 - Prime Bond 2.

View Article and Find Full Text PDF

The aim of this in vitro study was to evaluate the extent of marginal leakage with class II composite resin restorations associated with different materials. Twenty extracted sound molars were disinfected and stored in 0.9% saline solution.

View Article and Find Full Text PDF