Assessing the position of the Bragg peak (BP) in hadron radiotherapy utilizing prompt-gamma imaging (PGI) presents many challenges in terms of detector physics. Gamma detectors with the capability of extracting the best energy, timing, and spatial information from each gamma interaction, as well as with high detection efficiency and count rate performance, are needed for this application. In this work we present the characterization of a pixel Čerenkov charge induction (CCI) thallium bromide (TlBr) detector in terms of energy and and electron drift time for its potential use in PGI.
View Article and Find Full Text PDFThallium bromide (TlBr) is a semiconductor material and, simultaneously, a good Cerenkov radiator. The performance of a TlBr detector that integrates two different readouts, the charge induction readout and the detection of Cerenkov light, was evaluated. A TlBr detector with dimensions of 4 × 4 × 5 mm, with a monolithic cathode and an anode segmented into strips, was manufactured.
View Article and Find Full Text PDFThallium bromide (TlBr) is a promising semiconductor detector material for positron emission tomography (PET) because it can offer very good energy resolution and 3D segmentation capabilities, and it also provides detection efficiency surpassing that of commonly used scintillators. Energy, timing, and spatial resolution were measured for thin (<1 mm) TlBr detectors. The energy and timing resolution were measured simultaneously for the same planar 0.
View Article and Find Full Text PDFThe feasibility of using Cerenkov light, generated by energetic electrons following 511 keV photon interactions in the semiconductor TlBr, to obtain fast timing information for positron emission tomography (PET) was evaluated. Due to its high refractive index, TlBr is a relatively good Cerenkov radiator and with its wide bandgap, has good optical transparency across most of the visible spectrum. Coupling an SiPM photodetector to a slab of TlBr (TlBr-SiPM) yielded a coincidence timing resolution of 620 ps FWHM between the TlBr-SiPM detector and a LFS reference detector.
View Article and Find Full Text PDFAn experimental method for determining the range of alpha particles in films based on I-V(s) analysis has been suggested. The range of 5.5 MeV alpha particles in PbI(2) films determined by this technique is 30+/-5 microm, and this value is in agreement with the value calculated by SRIM (the stopping and range of ions in matter), r=24 microm in PbI(2).
View Article and Find Full Text PDF