Background And Purpose: Diffusion-weighted imaging (DWI) using single-shot echo planar imaging (DW-EPI) is susceptible to distortions around air-filled cavities and dental fillings, typical for the head and neck area. Non-EPI, Split acquisition of fast spin echo signals for diffusion imaging (DWSPLICE) could reduce these distortions and enhance image quality, thereby potentially improving recurrence assessment in squamous cell carcinoma (SCC) of the head and neck region. This study evaluated whether DW-SPLICE is a viable alternative to DW-EPI through quantitative and qualitative analyses.
View Article and Find Full Text PDFBackground: Tumour hypoxia is a negative predictive and prognostic biomarker in colorectal cancer typically assessed by invasive sampling methods, which suffer from many shortcomings. This retrospective proof-of-principle study explores the potential of MRI-derived imaging markers in predicting tumour hypoxia non-invasively in patients with colorectal liver metastases (CLM).
Methods: A single-centre cohort of 146 CLMs from 112 patients were segmented on preoperative T2-weighted (T2W) images and diffusion-weighted imaging (DWI).
Objectives: Diffusion-weighted magnetic resonance imaging (MRI) is gaining popularity as an addition to standard dynamic contrast-enhanced breast MRI. Although adding diffusion-weighted imaging (DWI) to the standard protocol design would require increased scanning-time, implementation during the contrast-enhanced phase could offer a multiparametric MRI protocol without any additional scanning time. However, gadolinium within a region of interest (ROI) might affect assessments of DWI.
View Article and Find Full Text PDFAn increasing number of breast cancer patients develop brain metastases (BM). Standard-of-care treatments are largely inefficient, and breast cancer brain metastasis (BCBM) patients are considered untreatable. Immunotherapies are not successfully employed in BCBM, in part because breast cancer is a "cold" tumor and also because the brain tissue has a unique immune landscape.
View Article and Find Full Text PDFQuantitative MRI has the potential to produce imaging biomarkers for the prediction of early response to radiotherapy treatment. In this pilot study, a potential imaging biomarker, the T relaxation time, is assessed for this purpose. A T sequence was implemented on a 1.
View Article and Find Full Text PDFThis review aims to identify factors causing heterogeneity in breast DWI-MRI and their impact on its value for identifying breast cancer patients with pathological complete response (pCR) on neoadjuvant systemic therapy (NST). A search was performed on PubMed until April 2020 for studies analyzing DWI for identifying breast cancer patients with pCR on NST. Technical and clinical study aspects were extracted and assessed for variability.
View Article and Find Full Text PDFKnowledge of patient-specific liver anatomy is key to patient safety during major hepatobiliary surgery. Three-dimensional (3D) models of patient-specific liver anatomy based on diagnostic MRI images can provide essential vascular and biliary anatomical insight during surgery. However, a method for generating these is not yet publicly available.
View Article and Find Full Text PDFPurpose: In about 30% of patients treated with neoadjuvant chemoradiotherapy (nCRT) followed by surgical resection for locally advanced oesophageal cancer no vital tumour is found in the resection specimen. Accurate clinical response assessment is critical if deferral from surgery is considered in complete responders. Our study aimed to compare the performance of MRI and of FDG-PET/CT for the detection of residual disease after nCRT.
View Article and Find Full Text PDFSwallowing muscle strength exercises are effective in restoring swallowing function. In order to perform the exercises with progressive load, the swallow exercise aid (SEA) was developed. Precise knowledge on which muscles are activated with swallowing exercises, especially with the SEA, is lacking.
View Article and Find Full Text PDFAccurate assessment of 3D models of patient-specific anatomy of the liver, including underlying hepatic and biliary tree, is critical for preparation and safe execution of complex liver resections, especially due to high variability of biliary and hepatic artery anatomies. Dynamic MRI with hepatospecific contrast agents is currently the only type of diagnostic imaging that provides all anatomical information required for generation of such a model, yet there is no information in the literature on how the complete 3D model can be generated automatically. In this work, a new automated segmentation workflow for extraction of patient-specific 3D model of the liver, hepatovascular and biliary anatomy from a single multiphase MRI acquisition is developed and quantitatively evaluated.
View Article and Find Full Text PDFFor the validation of optical diagnostic technologies, experimental results need to be benchmarked against the gold standard. Currently, the gold standard for tissue characterization is assessment of hematoxylin and eosin (H&E)-stained sections by a pathologist. When processing tissue into H&E sections, the shape of the tissue deforms with respect to the initial shape when it was optically measured.
View Article and Find Full Text PDFPurpose: Systems for magnetic resonance (MR-) guided radiotherapy enable daily MR imaging of cancer patients during treatment, which is of interest for treatment response monitoring and biomarker discovery using quantitative MRI (qMRI). Here, the performance of a 1.5 T MR-linac regarding qMRI was assessed on phantoms.
View Article and Find Full Text PDFPurpose: Assess whether application of a micro-enema can reduce gas-induced susceptibility artefacts in Single-shot Echo Planar Imaging (EPI) Diffusion-weighted imaging of the rectum at 1.5 T.
Materials And Methods: Retrospective analysis of n = 50 rectal cancer patients who each underwent multiple DWI-MRIs (1.
Rationale And Objectives: This study aims to evaluate if navigator-echo respiratory-triggered magnetic resonance acquisition can acquire supine high-quality breast magnetic resonance imaging (MRI).
Materials And Methods: Supine respiratory-triggered magnetic resonance imaging (Trig-MRI) was compared to supine non-Trig-MRI to evaluate breathing-induced motion artifacts (group 1), and to conventional prone non-Trig-MRI (group 2, 16-channel breast coil), all at 3T. A 32-channel thorax coil was placed on top of a cover to prevent breast deformation.
Our aim is to develop a clinically viable, fast-acquisition, prostate MR elastography (MRE) system with transperineal excitation. We developed a new actively shielded electromagnetic transducer, designed to enable quick deployment and positioning within the scanner. The shielding of the transducer was optimized using simulations.
View Article and Find Full Text PDFIn MR elastography (MRE), periodic tissue motion is phase encoded using motion-encoding gradients synchronized to an externally applied periodic mechanical excitation. Conventional methods result in extended scan time for quality phase images, thus limiting the broad application of MRE in the clinic. For practical scan times, researchers have been relying on one-dimensional or two-dimensional motion-encoding, low-phase sampling and a limited number of slices, and artifact-prone, single-shot, echo planar imaging (EPI) readout.
View Article and Find Full Text PDFJ Magn Reson Imaging
February 2013
Purpose: To validate the reproducibility of a chemical shift imaging (CSI) acquisition protocol with parallel imaging, using automated repositioning software.
Materials And Methods: Ten volunteers were imaged three times on two different 3 Tesla (T) MRI scanners, receiving anatomical imaging and two identical CSI measurements, using automated repositioning software for consistent repositioning of the CSI grid. Offcenter parameters of the CSI plane were analyzed.
Purpose: To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs).
Materials And Methods: Twenty-five patients suspected for colorectal liver metastases were prospectively included. Lesion detection and characterization were compared between all SS SE-EPI and T2-weighted turbo spin echo (T2w TSE) sets (two-sided Fisher's exact test).
Fluoro-18-deoxyglucose positron emission tomography computed tomography (FDG-PET/CT) and magnetic resonance imaging (MRI), including unenhanced single-shot spin-echo echo planar imaging (SS SE-EPI) and small paramagnetic iron oxide (SPIO) enhancement, were compared prospectively for detecting colorectal liver metastases. Twenty-four consecutive patients suspected for metastases underwent MRI and FDG-PET/CT. Fourteen patients (58%) had previously received chemotherapy, including seven patients whose chemotherapy was still continuing to within 1 month of the PET/CT study.
View Article and Find Full Text PDFThe purpose of this study was to prospectively compare the performance of magnetic resonance (MR) elastography using echo-planar and spin-echo imaging for staging of hepatic fibrosis. Twenty-four patients who had liver biopsy for suspicion of chronic liver disease had MR elastography performed with both spin-echo and echo-planar sequences. At histology, the fibrosis stage was assessed according to METAVIR.
View Article and Find Full Text PDFBackground & Aims: The purpose of our study was to prospectively compare the success rate and diagnostic accuracy of magnetic resonance elastography, ultrasound elastography, and aspartate aminotransferase to platelets ratio index (APRI) measurements for the noninvasive staging of fibrosis in patients with chronic liver disease.
Methods: We performed a prospective blind comparison of magnetic resonance elastography, ultrasound elastography, and APRI in a consecutive series of patients who underwent liver biopsy for chronic liver disease in a university-based hospital. Histopathologic staging of liver fibrosis according to the METAVIR scoring system served as the reference.
The order parameters of a number of different solutes dissolved in a number of different nematic liquid-crystal solvents are measured and compared. It is shown that the order parameters can all be rationalized with the ansatz that there exist two independent ordering mechanisms operating in the liquid crystals employed. With this ansatz it is possible to fit the experimental order parameters to better than 5%.
View Article and Find Full Text PDFPurpose: To prospectively compare single-shot spin-echo echo-planar imaging (SSSE-EPI) using b = 0, 10, 150, and 400 seconds/mm(2) with standard MRI techniques after intravenous super paramagnetic iron oxide (SPIO) in the detection and characterization of focal liver lesions with focus on small (<10 mm) focal liver lesions.
Materials And Methods: A total of 25 patients suspected for colorectal liver metastases were included. Number of detected lesions was evaluated.
Purpose: To assess the added value of true diffusion (D), perfusion factor (f) and apparent diffusion coefficient at low b-values (ADC(low)) for differentiation between liver metastases and hemangiomas based on respiratory-triggered high-resolution Black-Blood Single-Shot SpinEcho Echo Planar Imaging (BB SS SE-EPI).