Background Takotsubo syndrome (TS) and myocardial infarction (MI) share similar clinical and laboratory characteristics but have important differences in causes, demographics, management, and outcomes. Methods and Results In this observational study, the National Inpatient Sample and National Readmission Database were used to identify patients admitted with TS, type 1 MI, or type 2 MI in the United States between October 1, 2017, and December 31, 2019. We compared patients hospitalized with TS, type 1 MI, and type 2 MI with respect to key features and outcomes.
View Article and Find Full Text PDFBackground: High-power, short-duration (HPSD) radiofrequency ablation (RFA) may reduce ablation time. Concerns that catheter-mounted thermocouples (TCs) can underestimate tissue temperature, resulting in elevated risk of steam pop formation, potentially limit widespread adoption of HPSD ablation.
Objective: The purpose of this study was to compare the safety and efficacy of HPSD and low-power, long-duration (LPLD) RFA in the context of pulmonary vein isolation (PVI).
Delivery of comprehensive arrhythmia care requires the simultaneous presence of many resources. These include complex hospital infrastructure, expensive implantable equipment, and expert personnel. In many low- and middle-income countries (LMICs), at least 1 of these components is often missing, resulting in a gap between the demand for arrhythmia care and the capacity to supply care.
View Article and Find Full Text PDFBackground Most published reports describing outcomes of patients with cardiovascular implantable electronic device-related infective endocarditis (CIED-IE) are single-center studies with small patient sample sizes. The goal of this study was to utilize population-based data to assess trends in CIED-IE hospitalization and to compare outcomes between patients hospitalized with CIED-IE, prosthetic valve endocarditis (PVE), and native valve endocarditis (NVE). Methods and Results A query of the National (Nationwide) Inpatient Sample (NIS) database between 2003 and 2017 identified 646 325 patients hospitalized with infective endocarditis in the United States of whom 585 974 (90%) had NVE, 27 257 (4.
View Article and Find Full Text PDFJ Innov Card Rhythm Manag
February 2022
Ultrasound (US) guidance has been shown to be a safe and effective option for gaining access to the axillary vein during implantation of cardiovascular implantable electronic devices (CIEDs). However, US-based technique has not been universally adopted in CIED implantations performed in cardiac electrophysiology (EP) laboratories, despite potential advantages over other vascular access techniques. For this reason, not all cardiac electrophysiologists have been trained to use US guidance during CIED implantation.
View Article and Find Full Text PDFBackground: Cardiovascular events in the context of COVID-19 infection increase the risk of negative patient outcomes, but large cohort studies describing this association are limited. The purpose of the current study was to investigate the potential associations between cardiovascular events and mortality in patients hospitalized due to COVID-19.
Methods: A retrospective chart review was performed in 2450 patients hospitalized for confirmed COVID-19 infection within a single hospital network between March 15 and June 15, 2020.
Chikungunya virus (CHIKV) infection causes acute disease characterized by fever, rash and arthralgia, which progresses to severe and chronic arthritis in up to 50% of patients. Moreover, CHIKV infection can be fatal in infants or immunocompromised individuals and has no approved therapy or prevention. This phase 1, first-in-human, randomized, placebo-controlled, proof-of-concept trial conducted from January 2019 to June 2020 evaluated the safety and pharmacology of mRNA-1944, a lipid nanoparticle-encapsulated messenger RNA encoding the heavy and light chains of a CHIKV-specific monoclonal neutralizing antibody, CHKV-24 ( NCT03829384 ).
View Article and Find Full Text PDFBackground: Lyme carditis, defined as direct infection of cardiac tissue by Borrelia bacteria, affects up to 10% of patients with Lyme disease. The most frequently reported clinical manifestation of Lyme carditis is cardiac conduction system disease. The goal of this study was to identify the incidence and predictors of permanent pacemaker implantation in patients hospitalized with Lyme disease.
View Article and Find Full Text PDFPurpose Of Review: Atrial fibrillation (AF) is the most common arrhythmia in adults and is responsible for 600,000 emergency department (ED) visits each year in the USA. Over 60% of these patients are admitted to inpatient units. The prevalence of AF is increasing, resulting in higher numbers of AF-related ED visits and inpatient admissions.
View Article and Find Full Text PDFLeft atrial appendage closure (LAAC) is an important strategy to reduce stroke risk in patients with non-valvular atrial fibrillation (AF) who are at high risk of bleeding on long-term anticoagulation. Real-world assessments of the safety of the Watchman LAAC device remain limited. The objective of this study was to determine the frequency and timing of adverse events associated with Watchman LAAC device implants performed after FDA approval.
View Article and Find Full Text PDFBackground Variability in the management of atrial fibrillation (AF) in the emergency department (ED) leads to avoidable hospital admissions and prolonged length of stay (LOS). In a retrospective single-center study, a multidisciplinary AF treatment pathway was associated with a reduced hospital admission rate and reduced LOS. To assess the applicability of the AF pathway across institutions, we conducted a 2-center study.
View Article and Find Full Text PDFBioprinting has emerged as a promising tool in tissue engineering and regenerative medicine. Various 3D printing strategies have been developed to enable bioprinting of various biopolymers and hydrogels. However, the incorporation of biological factors has not been well explored.
View Article and Find Full Text PDFAims: Delivery of high-power short-duration radiofrequency (RF) ablation lesions is not commonly used, in part because conventional thermocouple (TC) technology underestimates tissue temperature, increasing the risk of steam pop, and thrombus formation. We aimed to test whether utilization of an ablation catheter equipped with a highly accurate novel TC technology could facilitate safe and effective delivery of high-power RF lesions.
Methods And Results: Adult male Yorkshire swine were used for the study.
Introduction: Manual, point-by-point electroanatomical mapping requires the operator to directly evaluate each point during map construction. Consequently, point collection can be a slow process. An automated 3D mapping system was developed with the goal of improving key mapping metrics, including map completion time and point density.
View Article and Find Full Text PDFPurpose: We have recently reported a method for measuring rest-stress myocardial blood flow (MBF) using a single, relatively short, PET scan session. The method requires two IV tracer injections, one to initiate rest imaging and one at peak stress. We previously validated absolute flow quantitation in ml/min/cc for standard bull's eye, segmental analysis.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
August 2017
Atrial fibrillation (AF) is frequently observed in patients being treated for cancer and can lead to increased morbidity and mortality in this population. With the use of newer, targeted cancer therapies, several drug-drug interactions have emerged that complicate the use of antiarrhythmic drugs (AADs) in patients with active malignancy. Moreover, specific targeted therapies such as ibrutinib may contribute directly to the development of AF.
View Article and Find Full Text PDFManagement of atrial fibrillation (AF) in the emergency department (ED) is variable because of the absence of universally adopted treatment guidelines. To address potentially preventable hospital admissions and prolonged length of stay, an AF treatment pathway was co-developed by physicians from the cardiac electrophysiology service and the department of emergency medicine at our institution. The impact of this AF pathway on patient outcomes was evaluated with a prospective, observational study conducted in a single tertiary care center from July 1, 2013, to June 30, 2014.
View Article and Find Full Text PDFBackground: Recurrent dissection of a previously dissected aortic segment has been reported as a rare, late complication in single case reports. The infrequency of this event makes informed risk assessment in an individual patient challenging.
Methods: To investigate this issue we examined the database of the Massachusetts General Hospital Thoracic Aortic Center between January 1, 2003 and December 31, 2012.
Pacing Clin Electrophysiol
March 2015
Background: Magnetic resonance imaging (MRI) has been considered contraindicated in patients with cardiac pacemakers (PPMs). Recently, Medtronic (MDT) MRI SureScan PPM (Medtronic Inc., Minneapolis, MN, USA) and leads were introduced into clinical practice in the United States of America.
View Article and Find Full Text PDFIn a cell-free approach to regenerative therapeutics, transient application of paracrine factors in vivo could be used to alter the behavior and fate of progenitor cells to achieve sustained clinical benefits. Here we show that intramyocardial injection of synthetic modified RNA (modRNA) encoding human vascular endothelial growth factor-A (VEGF-A) results in the expansion and directed differentiation of endogenous heart progenitors in a mouse myocardial infarction model. VEGF-A modRNA markedly improved heart function and enhanced long-term survival of recipients.
View Article and Find Full Text PDF