Objective: Helical stents have been developed to treat peripheral arterial disease (PAD) in the superficial femoral artery (SFA), with the premise that their particular geometry could promote swirling flow in the blood. The aim of this work is to provide evidence on the existence of this swirling flow by quantifying its signatures.
Materials And Methods: This study consists of in vitro and in vivo parts.
Purpose: To investigate the accuracy of high-framerate echo particle image velocimetry (ePIV) and computational fluid dynamics (CFD) for determining velocity vectors in femoral bifurcation models through comparison with optical particle image velocimetry (oPIV).
Approach: Separate femoral bifurcation models were built for oPIV and ePIV measurements of a non-stenosed (control) and a 75%-area stenosed common femoral artery. A flow loop was used to create triphasic pulsatile flow.
Purpose: To identify potential hemodynamic predictors for limb thrombosis (LT) following endovascular aneurysm repair with the Anaconda endograft in a patient-specific phantom.
Materials And Methods: A thin-walled flow phantom, based on a patient's aortic anatomy and treated with an Anaconda endograft, that presented with a left-sided LT was fabricated. Contrast-enhanced ultrasound particle image velocimetry was performed to quantify time-resolved velocity fields.
Aims: Reflection magnitude (RM), the ratio of the amplitudes of the backward and forward central arterial pressure waves, has been shown to predict cardiovascular events. However, the association with blood pressure (BP) and hypertension is unclear.
Methods: We assessed RM in 10 195 individuals of Dutch, South-Asian Surinamese, African Surinamese, Ghanaian, Turkish and Moroccan origin aged between 18 and 70 years (54.
Purpose: Contemporary diagnostic modalities, including contrast-enhanced computed tomography (CTA) and duplex ultrasound, have been insufficiently able to predict endograft thrombosis. This study introduces an implementation of image-based computational fluid dynamics (CFD), by exemplification with 4 patients treated with an endograft for occlusive disease of the superficial femoral artery (SFA). The potential of personalized CFD for predicting endograft thrombosis is investigated.
View Article and Find Full Text PDFPurpose: To compare the flow patterns and hemodynamics of the AFX stent-graft and the covered endovascular reconstruction of aortic bifurcation (CERAB) configuration using laser particle image velocimetry (PIV) experiments.
Materials And Methods: Two anatomically realistic aortoiliac phantoms were constructed using polydimethylsiloxane polymer. An AFX stent-graft with a transparent cover made with a new method was inserted into one phantom.
The assessment of local blood flow patterns in patients with peripheral arterial disease is clinically relevant, since these patterns are related to atherosclerotic disease progression and loss of patency in stents placed in peripheral arteries, through mechanisms such as recirculating flow and low wall shear stress (WSS). However, imaging of vascular flow in these patients is technically challenging due to the often complex flow patterns that occur near atherosclerotic lesions. While several flow quantification techniques have been developed that could improve the outcomes of vascular interventions, accurate 2D or 3D blood flow quantification is not yet used in clinical practice.
View Article and Find Full Text PDFPurpose: To evaluate the impact of elective endovascular aneurysm repair (EVAR) on the carotid-femoral pulse wave velocity (cfPWV) and central pressure waveform, through 1-year follow-up.
Materials And Methods: A tonometric device was used to measure cfPWV and estimate the central pressure waveform in 20 patients with an infrarenal abdominal aortic aneurysm scheduled for elective EVAR. The evaluated central hemodynamic parameters included the central pressures, the augmentation index (AIx), and the subendocardial viability ratio (SEVR).
Background: Glomerular hyperfiltration resulting from an elevated intraglomerular pressure (Pglom) is an important cause of CKD, but there is no feasible method to directly assess Pglom in humans. We developed a model to estimate Pglom in patients from combined renal arterial pressure and flow measurements.
Methods: We performed hemodynamic measurements in 34 patients undergoing renal or cardiac angiography under baseline conditions and during hyperemia induced by intrarenal dopamine infusion (30 g/kg).
Having physiological correct flow waveforms is a key feature for experimental studies of blood flow, especially in the process of developing and testing a new medical device such as stent, mechanical heart valve, or any implantable medical device that involves circulation of blood through the device. It is also a critical part of a perfusion system for cardiopulmonary bypass and extracorporeal membrane oxygenation procedures. This study investigated the feasibility of a novel roller pump for use in experimental flow phantoms.
View Article and Find Full Text PDFPurpose: To describe a proximal extension of a failed chimney endovascular aneurysm sealing repair (chEVAS) using a chEVAS-in-chEVAS procedure in 2 cases with successful treatment outcome at 2-year follow-up.
Case Report: Two patients with an infrarenal abdominal aortic aneurysm were treated with an elective chEVAS procedure with 1 chimney stent for a unilateral renal artery. At 18 and 24 months, respectively, both patients showed aneurysm growth with an associated decrease in proximal seal.
Objective: Augmentation index (AIx) is often used to quantify the contribution of wave reflection to central pulse pressure. Recent studies have challenged this view by showing how contractility-induced changes in the forward pressure wave can markedly impact AIx. We hypothesized that changes in preload will also affect AIx through changes in the forward wave and studied this in two experiments.
View Article and Find Full Text PDFObjective: To achieve an optimal sealing zone during endovascular aneurysm repair, the intended positioning of the proximal end of the endograft fabric should be as close as possible to the most caudal edge of the renal arteries. Some endografts exhibit a small offset between the radiopaque markers and the proximal fabric edge. Unintended partial renal artery coverage may thus occur.
View Article and Find Full Text PDFPurpose: To examine the influence of device positioning and infrarenal neck diameter on flow patterns in the Nellix endovascular aneurysm sealing (EVAS) system.
Methods: The transition of the aortic flow lumen into two 10-mm-diameter stents after EVAS creates a mismatched area. Flow recirculation may affect local wall shear stress (WSS) profiles and residence time associated with atherosclerosis and thrombosis.