Publications by authors named "Lenka Stepan"

Objectives: To examine the efficacy of "slow" signs and patroller presence at "slow" signs to reduce speeds of snowsports participants, compared to a condition where no sign or patroller are present, independent of other factors that may contribute to skier slowing (such as prior knowledge, trail convergence, etc.).

Design And Methods: Snowsports participant speeds were measured on "more difficult" trails using a radar gun at two ski areas with: (1) no-sign - the usual condition for the trail, and (2) slow-sign - a large "slow" sign was posted in the middle of the trail.

View Article and Find Full Text PDF

Objectives: Develop a method to examine the effects of component geometry and force-deflection on the release process of Tech/Pin alpine touring (AT) ski boots and bindings.

Design And Methods: For seven AT boots, we measured the critical geometric dimensions of the metal inserts at the toe region of the boots. Binding geometry (including the pins and rocker arms) and the force-angular deflection curves of typical AT bindings were measured.

View Article and Find Full Text PDF

Objectives: The injury mitigation capabilities of foam, ski-area padding was examined for headfirst impacts.

Design And Methods: A custom-made pendulum impactor system was constructed using an instrumented, partial 50th-percentile-male Hybrid-III anthropomorphic testing device (ATD). For each test, the ATD was raised 1.

View Article and Find Full Text PDF

Interventionalists in many specialties have the need for improved, low profile covered stents. Thin films of nitinol (<5-10 microns) could be used to improve current covered stent technology. A "hot target" sputter deposition technique was used to create thin films of nitinol for this study.

View Article and Find Full Text PDF

In order to create a less thrombogenic heart valve with improved longevity, a prosthetic heart valve was developed using thin film nitinol (NiTi). A "butterfly" valve was constructed using a single, elliptical piece of thin film NiTi and a scaffold made from Teflon tubing and NiTi wire. Flow tests and pressure readings across the valve were performed in vitro in a pulsatile flow loop.

View Article and Find Full Text PDF

Stent-based transcatheter valves continue to require large sheaths inappropriate for deployment in children. Low-profile covered stent valves (CSVs) were constructed by removing triangular sections from two sides of partially expanded Palmaz P308 stents before covering the stents with 0.1 mm polytetrafluoroethylene.

View Article and Find Full Text PDF