Background: The objective of this study was to assess limb and component alignment after total knee arthroplasty (TKA) on long leg X-rays and to compare the use of iAssist, an accelerometric based computer-assisted device (CAD), with conventional jigs.
Methods: We prospectively recruited 56 consecutive patients undergoing primary unilateral TKA by a single surgeon into this study. In the first 28 patients iAssist navigation system was utilized and in the following 28 conventional jigs were used.