Introduction: Mobile phones, contaminated with pathogenic microorganisms, have the potential to act as "trojan horses". The microbial signatures present on their surfaces most probably vary across different geographical regions. As a result, mobile phones belonging to international conference attendees may serve as a model for global microbial dissemination, posing potential risks to public health and biosecurity.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
September 2024
Wearable magnetoencephalography based on optically pumped magnetometers (OPM-MEG) offers non-invasive and high-fidelity measurement of human brain electrophysiology. The flexibility of OPM-MEG also means it can be deployed in participants of all ages and permits scanning during movement. However, the magnetic fields generated by neuronal currents - which form the basis of the OPM-MEG signal - are much smaller than environmental fields, and this means measurements are highly sensitive to interference.
View Article and Find Full Text PDFDescription The Care Alert program is designed to help navigate encounters with patient populations that are high utilizers of emergency department (ED) resources. These populations often have chronic medical conditions, have a poor understanding of their conditions, are unfamiliar with the EDs' role in the management of these conditions, and commonly lack outpatient resources. The Care Alert program intends to address the needs of this challenging patient population by designing individualized care plans that are approved through a multidisciplinary committee.
View Article and Find Full Text PDFThe evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substrates remain poorly understood. Hyperscanning employs functional neuroimaging to simultaneously assess brain activity in two individuals and offers the best means to understand the neural basis of social interaction.
View Article and Find Full Text PDFThe ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions.
View Article and Find Full Text PDFMagnetoencephalography (MEG) measures the small magnetic fields generated by current flow in neural networks, providing a noninvasive metric of brain function. MEG is well established as a powerful neuroscientific and clinical tool. However, current instrumentation is hampered by cumbersome cryogenic field-sensing technologies.
View Article and Find Full Text PDFObjectives: To synthesize published research exploring emergency department (ED) communication strategies and decision-making with persons living with dementia (PLWD) and their care partners as the basis for a multistakeholder consensus conference to prioritize future research.
Design: Systematic scoping review.
Settings And Participants: PLWD and their care partners in the ED setting.
Magnetoencephalography (MEG) measures human brain function via assessment of the magnetic fields generated by electrical activity in neurons. Despite providing high-quality spatiotemporal maps of electrophysiological activity, current MEG instrumentation is limited by cumbersome field sensing technologies, resulting in major barriers to utility. Here, we review a new generation of MEG technology that is beginning to lift many of these barriers.
View Article and Find Full Text PDFIn rapid serial visual presentation (RSVP), accurate report of a critical item (C2) declines when an earlier critical item (C1) is identical rather than unrelated. The most prominent theories of this phenomenon of (RB) concern the effects of processing C1 on later processing of C2. However, characteristics of distractor items between C1 and C2 strongly moderate RB, suggesting that items may compete for registration as separate events.
View Article and Find Full Text PDFIntroduction: Increasingly, older adults are turning to emergency departments (EDs) to address healthcare needs. To achieve these research demands, infrastructure is needed to both generate evidence of intervention impact and advance the development of implementation science, pragmatic trials evaluation and dissemination of findings from studies addressing the emergency care needs of older adults. The Geriatric Emergency Care Applied Research Network (https://gearnetwork.
View Article and Find Full Text PDFOptically-pumped magnetometers (OPMs) are an established alternative to superconducting sensors for magnetoencephalography (MEG), offering significant advantages including flexibility to accommodate any head size, uniform coverage, free movement during scanning, better data quality and lower cost. However, OPM sensor technology remains under development; there is flexibility regarding OPM design and it is not yet clear which variant will prove most effective for MEG. Most OPM-MEG implementations have either used single-axis (equivalent to conventional MEG) or dual-axis magnetic field measurements.
View Article and Find Full Text PDFAdult participants learned homographic cue words and weakly associated targets. Each target was in the dominant (expected) sense of the cue (e.g.
View Article and Find Full Text PDFBackground: Optically pumped magnetometers (OPMs) have made moving, wearable magnetoencephalography (MEG) possible. The OPMs typically used for MEG require a low background magnetic field to operate, which is achieved using both passive and active magnetic shielding. However, the background magnetic field is never truly zero Tesla, and so the field at each of the OPMs changes as the participant moves.
View Article and Find Full Text PDFOptically-pumped magnetometers (OPMs) are highly sensitive, compact magnetic field sensors, which offer a viable alternative to cryogenic sensors (superconducting quantum interference devices - SQUIDs) for magnetoencephalography (MEG). With the promise of a wearable system that offers lifespan compliance, enables movement during scanning, and provides higher quality data, OPMs could drive a step change in MEG instrumentation. However, this potential can only be realised if background magnetic fields are appropriately controlled, via a combination of optimised passive magnetic screening (i.
View Article and Find Full Text PDFThere is increasing attention focussed on the risks associated with mobile phones possibly serving as 'Trojan Horse' fomites for microbial transmission in healthcare settings. However, little is reported on the presence of microbes on community derived mobile phones which in 2021, numbered in the billions in circulation with majority being used on a daily basis. Identify viable microbial organisms swabbed from smartphones on a university campus.
View Article and Find Full Text PDFThe optically pumped magnetometer (OPM) is a viable means to detect magnetic fields generated by human brain activity. Compared to conventional detectors (superconducting quantum interference devices) OPMs are small, lightweight, flexible, and operate without cryogenics. This has led to a step change in instrumentation for magnetoencephalography (MEG), enabling a "wearable" scanner platform, adaptable to fit any head size, able to acquire data whilst subjects move, and offering improved data quality.
View Article and Find Full Text PDFOptically-pumped magnetometers (OPMs) offer the potential for a step change in magnetoencephalography (MEG) enabling wearable systems that provide improved data quality, accommodate any subject group, allow data capture during movement and potentially reduce cost. However, OPM-MEG is a nascent technology and, to realise its potential, it must be shown to facilitate key neuroscientific measurements, such as the characterisation of brain networks. Networks, and the connectivities that underlie them, have become a core area of neuroscientific investigation, and their importance is underscored by many demonstrations of their disruption in brain disorders.
View Article and Find Full Text PDFSeveral new technologies have emerged promising new Magnetoencephalography (MEG) systems in which the sensors can be placed close to the scalp. One such technology, Optically Pumped MEG (OP-MEG) allows for a scalp mounted system that provides measurements within millimetres of the scalp surface. A question that arises in developing on-scalp systems is: how many sensors are necessary to achieve adequate performance/spatial discrimination? There are many factors to consider in answering this question such as the signal to noise ratio (SNR), the locations and depths of the sources, density of spatial sampling, sensor gain errors (due to interference, subject movement, cross-talk, etc.
View Article and Find Full Text PDFBackground And Problem: In Australia, interprofessional education has been embedded into pre-registration course accreditation standards. Little is known about Australian midwifery and medical students experiences of interprofessional learning when the focus is on emergency scenarios during birth.
Aim: This study aimed to evaluate student experience of Interprofessional Simulation-Based Learning workshops focused on emergency scenarios with midwifery and medical students.
Background: Although most observational studies identify viral or bacterial pathogens in 50% or less of patients hospitalized with community-acquired pneumonia (CAP), we previously demonstrated that a multi-test bundle (MTB) detected a potential pathogen in 73% of patients. This study compares detection rates for potential pathogens with the MTB versus the Biofire® Pneumonia FilmArray® panel (BPFA) multiplex PCR platform and presents an approach for integrating BPFA results as a foundation for subsequent antibiotic stewardship (AS) activities.
Methods: Between January 2017 to March 2018, all patients admitted for CAP were enrolled.
J Am Coll Emerg Physicians Open
December 2020
Background And Hypothesis: The authors investigate whether there is a difference in Press Ganey (PG; patient satisfaction scores) scores for the emergency physicians before and during the coronavirus disease 2019 (COVID-19) outbreak at a regional group of emergency departments in the southeastern United States. The authors hypothesize that decreases in emergency department volume, less emergency department boarding of admissions, reduced use of hallway beds, and favorable attitudes toward emergency physicians during the COVID-19 outbreak may influence patient satisfaction scores measured in the Press Ganey surveys.
Study Design And Methods: The authors performed a retrospective review of PG scores obtained over the prior 7 months at 8 larger teaching hospitals in the Southeast region (Florida, Georgia, and South Carolina).
Traditional magnetoencephalographic (MEG) brain imaging scanners consist of a rigid sensor array surrounding the head; this means that they are maximally sensitive to superficial brain structures. New technology based on optical pumping means that we can now consider more flexible and creative sensor placement. Here we explored the magnetic fields generated by a model of the human hippocampus not only across scalp but also at the roof of the mouth.
View Article and Find Full Text PDFMagnetoencephalography (MEG) is a powerful technique for functional neuroimaging, offering a non-invasive window on brain electrophysiology. MEG systems have traditionally been based on cryogenic sensors which detect the small extracranial magnetic fields generated by synchronised current in neuronal assemblies, however, such systems have fundamental limitations. In recent years, non-cryogenic quantum-enabled sensors, called optically-pumped magnetometers (OPMs), in combination with novel techniques for accurate background magnetic field control, have promised to lift those restrictions offering an adaptable, motion-robust MEG system, with improved data quality, at reduced cost.
View Article and Find Full Text PDF