The accuracy of the latest generation Dexcom G7 sensors in individuals with diabetes undergoing hemodialysis has not previously been investigated. Participants with diabetes undergoing hemodialysis were recruited, with paired sensor glucose from Dexcom G7 recorded with plasma glucose analyzed in the laboratory, as well as the Freestyle Precision Pro glucometer and EKF Biosen C-Line analyzer. Ten adults (median age 64.

View Article and Find Full Text PDF

Objective: The objective was to evaluate the safety and efficacy of ultra-rapid-acting insulin with the Boost and Ease-off features of the Cambridge hybrid closed-loop system.

Methods: A secondary analysis of Boost and Ease-off from two double-blind, randomized, crossover hybrid closed-loop studies comparing (1) Fiasp to insulin aspart (n = 25), and (2) Lyumjev to insulin lispro (n = 26) was carried out. Mean glucose on initialization of Boost and Ease-off, change in glucose 60 and 120 minutes after initialization, duration and frequency of use, mean glucose, and time in, above, and below target glucose range were calculated for periods of Boost use, Ease-off use, or neither.

View Article and Find Full Text PDF

The promotion of continuous glucose monitoring (CGM) to standard of care for type 1 diabetes and insulin-treated type 2 diabetes reflects a robust and wide evidence base for the technology's effectiveness supported by real-world efficacy data. Multiple CGM devices are available worldwide and are marketed, in part, based on accuracy data. In this Viewpoint, we argue that accuracy metrics are no longer a point of difference between CGM devices as almost all exceed an acceptable threshold.

View Article and Find Full Text PDF

The increasing incidence of type 2 diabetes, which represents 90% of diabetes cases globally, is a major public health concern. Improved glucose management reduces the risk of vascular complications and mortality; however, only a small proportion of the type 2 diabetes population have blood glucose levels within the recommended treatment targets. In recent years, diabetes technologies have revolutionised the care of people with type 1 diabetes, and it is becoming increasingly evident that people with type 2 diabetes can also benefit from these advances.

View Article and Find Full Text PDF

Aims: Impaired awareness of hypoglycaemia (IAH) increases the risk of severe hypoglycaemia in people with type 1 diabetes mellitus (T1DM). IAH can be reversed through meticulous avoidance of hypoglycaemia. Diabetic autonomic neuropathy (DAN) has been proposed as an underlying mechanism contributing to IAH; however, data are inconsistent.

View Article and Find Full Text PDF

Aims: To evaluate real-world outcomes in people with Type 1 Diabetes (PwT1D) initiated on Omnipod DASH® Insulin Management System.

Methods: Anonymized clinical data were submitted to a secure web-based tool within the National Health Service network. Hemoglobin A1c (HbA1c), sensor-derived glucometrics, total daily dose of insulin (TDD), and patient-reported outcome changes between baseline and follow-up were assessed.

View Article and Find Full Text PDF

To evaluate postprandial glucose control when applying (1) faster-acting insulin aspart (Fiasp) compared to insulin aspart and (2) ultra-rapid insulin lispro (Lyumjev) compared to insulin lispro using the CamAPS FX hybrid closed-loop algorithm. We undertook a secondary analysis of postprandial glucose excursions from two double-blind, randomized, crossover hybrid closed-loop studies contrasting Fiasp to standard insulin aspart, and Lyumjev to standard insulin lispro. Endpoints included incremental area under curve (iAUC)-2h, iAUC-4h, 4 h postprandial time in target range, time above range, and time below range.

View Article and Find Full Text PDF

Aims: The FLASH-UK trial showed lower HbA1c with intermittently scanned continuous glucose monitoring (isCGM), as compared with self monitoring of blood glucose (SMBG), in adults with type 1 diabetes and HbA1c ≥58 mmol/mol (≥7.5%). Here, we present results from the pre-specified subgroup analysis for the 24-week HbA1c (primary outcome) and selected sensor-based secondary outcomes.

View Article and Find Full Text PDF

Objective: We previously showed that intermittently scanned continuous glucose monitoring (isCGM) reduces HbA1c at 24 weeks compared with self-monitoring of blood glucose with finger pricking (SMBG) in adults with type 1 diabetes and high HbA1c levels (58-97 mmol/mol [7.5%-11%]). We aim to assess the economic impact of isCGM compared with SMBG.

View Article and Find Full Text PDF

Objective: We explored longitudinal changes associated with switching to hybrid closed-loop (HCL) insulin delivery systems in adults with type 1 diabetes and elevated HbA1c levels despite the use of intermittently scanned continuous glucose monitoring (isCGM) and insulin pump therapy.

Research Design And Methods: We undertook a pragmatic, preplanned observational study of participants included in the National Health Service England closed-loop pilot. Adults using isCGM and insulin pump across 31 diabetes centers in England with an HbA1c ≥8.

View Article and Find Full Text PDF
Article Synopsis
  • * Researchers analyzed data from 88 participants across various age groups, finding that children and adolescents spent the most time in hypoglycemia, followed by young children, adults, and older adults.
  • * Overall, hypoglycemia rates were lower during the night compared to the daytime for all age groups, highlighting that younger individuals faced the highest hypoglycemia risk during insulin delivery.
View Article and Find Full Text PDF

Aims: Use of the CamAPS FX hybrid closed loop (CL) system is associated with improved time in range and glycated haemoglobin A1c across the age span, but little is known about its effects on patient-reported outcomes (PROs).

Methods: This open-label, randomized, multi-site study compared CamAPS FX to sensor-augmented pump (SAP) in a sample of older adults (≥60 years) with type 1 diabetes (T1D). Thirty-five older adults completed PROs surveys at the start of the study and after each period of 16 weeks using either CL or SAP.

View Article and Find Full Text PDF

Successful pancreas or islet transplantation is currently the only cure for type 1 diabetes mellitus. Since the first pancreas transplant in 1966, there have been various refinements of surgical technique along with improved immunosuppressive regimens, resulting in significantly improved outcomes, with contemporary research into graft monitoring and newer biomarkers, potentially lengthening graft survival rates further. Patients with insulin-dependent diabetes mellitus who are eligible for pancreas or islet transplantation represent a select group, the tip of the iceberg for a significant global diabetes disease burden.

View Article and Find Full Text PDF

The National Institute for Clinical Excellence updated guidance for continuous glucose monitoring (CGM) in 2022, recommending that CGM be available to all people living with type 1 diabetes. Manufacturers can trade in the UK with Conformité Européenne (CE) marking without an initial national assessment. The regulatory process for CGM CE marking, in contrast to the Food and Drug Administration (FDA) and Australian Therapeutic Goods Administration (TGA) process, is described.

View Article and Find Full Text PDF

Background: CamAPS FX is a hybrid closed-loop smartphone app used to manage type one diabetes. The closed-loop algorithm has a default target glucose of 5.8 mmol/L (104.

View Article and Find Full Text PDF

Objective: Many hybrid closed-loop (HCL) systems struggle to manage unusually high glucose levels as experienced with intercurrent illness or pre-menstrually. Manual correction boluses may be needed, increasing hypoglycemia risk with overcorrection. The Cambridge HCL system includes a user-initiated algorithm intensification mode ("Boost"), activation of which increases automated insulin delivery by approximately 35%, while remaining glucose-responsive.

View Article and Find Full Text PDF

Background: In persons with type 1 diabetes and high glycated hemoglobin levels, the benefits of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels are uncertain.

Methods: In a parallel-group, multicenter, randomized, controlled trial involving participants with type 1 diabetes and glycated hemoglobin levels between 7.5% and 11.

View Article and Find Full Text PDF