Rapid, on-site detection of fentanyl is of critical importance, as it is an extremely potent synthetic opioid that is prone to abuse. Here we describe a wearable glove-based sensor that can detect fentanyl electrochemically on the fingertips towards decentralized testing for opioids. The glove-based sensor consists of flexible screen-printed carbon electrodes modified with a mixture of multiwalled carbon nanotubes and a room temperature ionic liquid, 4-(3-butyl-1-imidazolio)-1-butanesulfonate).
View Article and Find Full Text PDFExposing a thiol-functionalised gold nanoparticle film chemiresistor to methanol in aqueous solution results in only a small electric current response as the thiol ligand/water partition coefficient of methanol is small, leading to only minor swelling of the chemiresistor film. Nevertheless, the current response to methanol can be enhanced if the chemiresistor becomes pre-exposed to a molecule with a large ligand/water partition coefficient P (e.g.
View Article and Find Full Text PDFDriving under the influence of cannabis and alcohol represents a major safety concern due to the synergistic or additive effect of these substances of abuse. Hence, rapid road-site testing of these substances is highly desired to reduce risks of fatal accidents. Here we describe a wearable electrochemical sensing device for the simultaneous direct, decentralized, detection of salivary THC and alcohol.
View Article and Find Full Text PDFThe increasing prevalence of fentanyl and its analogues as contaminating materials in illicit drug products presents a major hazard to first responder and law enforcement communities. Electrochemical techniques have the potential to provide critical information to these personnel via rapid, facile field detection of these materials. Here we demonstrate the use of cyclic square wave voltammetry (CSWV) with screen-printed carbon electrodes (SPCE), modified with the room temperature ionic liquid (RTIL) 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide [CCpyrr][NTf], toward such rapid "on-the-spot" fentanyl detection.
View Article and Find Full Text PDFIn this Account, we detail recent progress in wearable bioelectronic devices and discuss the future challenges and prospects of on-body noninvasive bioelectronic systems. Bioelectronics is a fast-growing interdisciplinary research field that involves interfacing biomaterials with electronics, covering an array of biodevices, encompassing biofuel cells, biosensors, ingestibles, and implantables. In particular, enzyme-based bioelectronics, built on diverse biocatalytic reactions, offers distinct advantages and represents a centerpiece of wearable biodevices.
View Article and Find Full Text PDFA flexible glove-based electrochemical biosensor with highly stretchable printed electrode system has been developed as a wearable point-of-use screening tool for defense and food security applications. This disposable-mechanically robust "lab-on-a-glove" integrates a stretchable printable enzyme-based biosensing system and active surface for swipe sampling on different fingers, and is coupled with a compact electronic interface for electrochemical detection and real-time wireless data transmission to a smartphone device. Stress-enduring inks are used to print the electrode system and the long serpentine connections to the wireless electronic interface.
View Article and Find Full Text PDFChemiresistor sensor arrays are a promising technology to replace current laboratory-based analysis instrumentation, with the advantage of facile integration into portable, low-cost devices for in-field use. To increase the performance of chemiresistor sensor arrays a high-throughput fabrication and screening methodology was developed to assess different organothiol-functionalized gold nanoparticle chemiresistors. This high-throughput fabrication and testing methodology was implemented to screen a library consisting of 132 different organothiol compounds as capping agents for functionalized gold nanoparticle chemiresistor sensors.
View Article and Find Full Text PDFFunctionalised gold nanoparticle (Au(NP)) chemiresistors are investigated for direct sensing of small organic molecules in biological fluids. The principle reason that Au(NP) chemiresistors, and many other sensing devices, have limited operation in biological fluids is due to protein and lipid fouling deactivating the sensing mechanism. In order to extend the capability of such chemiresistor sensors to operate directly in biofluids, it is essential to minimise undesirable matrix effects due to protein and lipidic components.
View Article and Find Full Text PDFWe investigate the response dynamics of 1-hexanethiol-functionalized gold nanoparticle chemiresistors exposed to the analyte octane in aqueous solution. The dynamic response is studied as a function of the analyte-water flow velocity, the thickness of the gold nanoparticle film and the analyte concentration. A theoretical model for analyte limited mass-transport is used to model the analyte diffusion into the film, the partitioning of the analyte into the 1-hexanethiol capping layers and the subsequent swelling of the film.
View Article and Find Full Text PDFp-Phosphonic acid calix[5]arene forms molecular capsules in water based on two of the molecules, which can be loaded with carboplatin using intense shearing, and attached to single wall carbon nano-tubes. Spin coating of the capsules onto a substrate affords 2 nm fibres of stacked calixarenes, with the self-assembly understood using molecular modelling.
View Article and Find Full Text PDFGold nanoparticle films (Au(NPF)) functionalized with a range of hydrophobic and hydrophilic thiols were assembled in chemiresistor sensor arrays that were used to differentiate between complex mixtures of analytes in the aqueous phase. A chemiresistor array sampled a simple system of linear alcohols (methanol, ethanol, propan-1-ol, and butan-1-ol) dissolved in water over a range of concentrations. Discriminant analysis confirmed that the response patterns of the array could be used to successfully distinguish between the different alcohol solutions at concentrations above 20 mM for all of the alcohols except methanol, which was distinguished at concentrations above 200 mM.
View Article and Find Full Text PDFMixing solutions of p-tBu-calix[5]arene and C(60) in toluene results in a 1:1 complex (C(60)) intersection(p-tBu-calix[5]arene), which precipitates as nanofibers. The principle structural unit is based on a host-guest ball-and-socket nanostructure of the two components, with an extended structure comprising zigzag/helical arrays of fullerenes (powder X-ray diffraction data coupled with molecular modeling). Under argon at temperatures above 309 degrees C, the fibers undergo selective volatilization of the calixarenes to afford C(60)-core nanostructures encapsulated in a graphitic material sheath, which exhibits a dramatic increase in surface area.
View Article and Find Full Text PDF