The entire musculo-skeletal system responds dynamically to stresses and strains applied to it. Restoring normal biomechanics contributes to the normal function that ensures that physiological stresses and strains are preserved. Appropriate preoperative planning is mandatory to restore normal biomechanics at reconstructive surgery.
View Article and Find Full Text PDFOsteoarthritis Cartilage
September 2013
Objective: Chronic pain after total knee replacement (TKR) is a prevalent condition, affecting about 20% of patients. The aim of this study was to explore the relationship between pre-operative pain thresholds and chronic pain after TKR.
Design: Patients listed for a TKR because of osteoarthritis participated in a Quantitative Sensory Testing (QST) session prior to surgery.
Resurfacing arthroplasty has fallen out of favour in recent years due to unfavourable survivorship in joint registries and alarming reports of soft tissue reactions around metal on metal prostheses. Our aim was to assess the effect of head size, implant design and component positioning on metal production by resurfacing arthroplasties. We measured whole blood cobalt and chromium and component position in matched populations implanted with two designs of resurfacing arthroplasty over a two-year period.
View Article and Find Full Text PDFIntroduction: There is an ongoing debate about the optimal use of metal-on-metal (MoM) bearings in total hip replacement, since there are uncertainties about local and systemic adverse effects due to wear and corrosion of these bearings. Despite various national recommendations, efforts to achieve international harmonization of specific evidence-based recommendations for best practice are still lacking.
Hypothesis: An international consensus study group should be able to develop recommendations on the use and monitoring of MoM bearings, preferably at the European level, through a multidisciplinary approach, by integrating the perspectives of various stakeholders.
Total hip arthroplasty is well established as a successful treatment for end stage arthritis, with a wide variety of components currently available. Using traditional stemmed implants in patients with a distorted proximal femur can be technically challenging with an increased risk of complications. We present seven patients with distorted proximal femoral anatomy or failed hip arthroplasty in whom a short, metaphyseal loading implant was utilised.
View Article and Find Full Text PDFThe clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data.
View Article and Find Full Text PDFThere has been increasing focus on bone conservation through proximal fixation in primary hip arthroplasty. However, the debate regarding fixation in revision arthroplasty and which factors influence implant choice remains less clear-cut. We report a case involving fatigue fracture of a long, distally well-fixed, uncemented revision stem.
View Article and Find Full Text PDFObjective: The aim of this study was to use quantitative sensory testing (QST) to explore the range and prevalence of somatosensory abnormalities demonstrated by patients with advanced knee OA.
Methods: One hundred and seven knee OA patients and 50 age- and sex-matched healthy participants attended a 1-h QST session. Testing was performed on the medial side of the knee and the pain-free forearm.
Accurate component alignment and joint line reproduction in total knee replacement (TKR) is crucial for successful clinical outcome. Advances in instrumentation and better understanding of the biomechanics can help to achieve better three dimensional alignments of TKR components and joint line restoration. We compared the accuracy of component alignment and joint line restoration with the use of 2 different TKR instrumentation kits (an older Gobot and a newer Xcelerate).
View Article and Find Full Text PDFOsteoarthritis Cartilage
June 2011
Quantitative Sensory Testing (QST), which assesses somatosensory function by recording participant's responses to external stimuli of controlled intensity, is a useful tool to provide insight into the complex pathophysiology of osteoarthritis (OA) pain. However, QST is not commonly used in rheumatology because the test-retest reliability properties of QST in OA patients have not yet been established. This brief report presents the finding of a study which assessed the test-retest reliability of light touch thresholds, pressure pain thresholds, thermal sensation thresholds and thermal pain thresholds in 50 knee OA patients and 50 healthy participants.
View Article and Find Full Text PDFPersistent postsurgical pain is a prevalent but underacknowledged condition. The aim of this study was to assess the prevalence, sensory qualities, and postoperative determinants of persistent pain at 3 to 4years after total knee replacement (TKR) and total hip replacement (THR). Patients completed a questionnaire with included the Western Ontario and McMaster Universities Index of Osteoarthritis (WOMAC) Pain Scale, PainDetect Questionnaire, Short-Form McGill Pain Questionnaire, and questions about general health and socioeconomic status.
View Article and Find Full Text PDFBMC Musculoskelet Disord
September 2010
Orthop Traumatol Surg Res
December 2010
With certain concerns recently reported on metal-on-metal bearing couples in total hip arthroplasty, this study's objective is to review the current knowledge concerning release of metal ions and its potential consequences. Each metal-on-metal implant presents different tribological properties. The analytical techniques for metals are accurate and the Co ion rates seem acceptable up to 2 μg/L.
View Article and Find Full Text PDFArthritis Care Res (Hoboken)
September 2010
Objective: To explore patients' perspectives of need for total joint replacement associated with decision making in orthopaedic consultations for hip or knee osteoarthritis.
Methods: Twenty-six orthopaedic consultations in 3 UK hospitals were observed and audio recorded, and semistructured interviews were conducted with the involved patients and clinicians. Data were analyzed using thematic analysis.
Aim: Measuring facts about disability may not reflect their personal impact. An individualized values instrument has been used to weight difficulty in performing activities of daily living in rheumatoid arthritis, and calculate personal impact (Personal Impact Health Assessment Questionnaire; PI HAQ). This study aimed to evaluate the PI HAQ in osteoarthritis (OA).
View Article and Find Full Text PDFArthritis of the hip primarily involves the joint surfaces. Intuitively the principal objective in the surgical management of arthritis is to replace the damaged articular surfaces. However, early attempts at conservative replacement failed both because of inadequate fixation and failure of the articulation.
View Article and Find Full Text PDFObjective: With digital radiography development, information technology (IT) companies have developed specific software for templating procedures, requiring individual magnification assessments for each patient. The aim of this study was to determine the mean magnification factor of digital radiographs and to evaluate the possibility of using the mean magnification factor or clinical information in templating.
Materials And Methods: We retrospectively evaluated 100 primary total hip arthroplasty digital radiographs using the femoral head prosthesis as a calliper to determinate the mean magnification factor.
Background And Purpose: Dual-energy X-ray absorptiometry (DXA) analysis of the 7 periprosthetic Gruen zones is the most commonly used protocol to evaluate bone remodeling after the implantation of conventional femoral stems. We assessed the value of DXA after cementless primary total hip arthroplasty (THA) by comparing the effect of progressive shortening of the stem of two femoral implants on periprosthetic bone remodeling using a specifically developed protocol of analysis with 5 periprosthetic regions of interest (ROIs).
Patients And Methods: Bone mineral density (BMD) was evaluated in 37 patients in the plateau stage, 3 years after THA.
We undertook a randomised controlled trial to compare the outcomes of skin adhesive and staples for skin closure in total hip replacement. The primary outcome was the cosmetic appearance of the scar at three months using a surgeon-rated visual analogue scale. In all, 90 patients were randomised to skin closure using either skin adhesive (n = 45) or staples (n = 45).
View Article and Find Full Text PDFImpaction bone grafting is a useful technique in the armament of a revision hip surgeon. Traditionally fresh frozen allograft has been used for this technique. However there are concerns about the transmission of viral proteins and prions through this form of allograft.
View Article and Find Full Text PDFBackground And Purpose: One of the greatest problems of revision hip arthroplasty is dealing with lost bone stock. Good results have been obtained with impaction grafting of allograft bone. However, there have been problems of infection, reproducibility, antigenicity, stability, availability of bone, and cost.
View Article and Find Full Text PDFBackground: Total hip joint replacement (THR) is a high volume, effective intervention for hip osteoarthritis (OA). However, indications and determinants of outcome remain unclear. The 'EUROHIP consortium' has undertaken a cohort study to investigate these questions.
View Article and Find Full Text PDF