Publications by authors named "Le Chong"

Background: Computed tomography (CT) is the gold standard imaging modality for the assessment of 3D bony morphology but incurs the cost of ionizing radiation exposure. High-resolution 3D magnetic resonance imaging (MRI) with CT-like bone contrast (CLBC) may provide an alternative to CT in allowing complete evaluation of both bony and soft tissue structures with a single MRI examination.

Purpose: To review the technical aspects of an optimized stack-of-stars 3D gradient recalled echo pulse sequence method (3D-Bone) in generating 3D MR images with CLBC, and to present a pictorial review of the utility of 3D-Bone in the clinical assessment of common musculoskeletal conditions.

View Article and Find Full Text PDF

Introduction The calcaneus is the most commonly fractured tarsal bone, accounting for up to 60% of tarsal bone fractures and 2% of all fractures in the body. With the calcaneus playing an important role in maintaining a stable and efficient bipedal gait, the sequelae of these injuries have also been associated with potential long-term disability or discomfort, especially if improperly managed. Incorrectly sized implants similarly cause their own set of complications, such as poor fixation, impingement, or implant prominence.

View Article and Find Full Text PDF

Atypical femoral fractures (AFFs) are rare adverse effects of bisphosphonate therapy. We report an unusual case of bilateral diaphyseal AFFs in an antiresorptive-naïve Singaporean Chinese female with Graves' disease. She presented with complete right AFF requiring surgical fixation, and persistent left incomplete AFF for over four years.

View Article and Find Full Text PDF

Introduction: Due to long wait times, rising demand and limited resources for Magnetic Resonance Imaging (MRI) services, phone call reminders were implemented as an intervention to increase scanner utilisation and improve non-attendance at the radiology department in Changi General Hospital, Singapore.

Aim: This study aims to evaluate the impact of phone reminders on outpatient MRI non-attendance rate as well as the operational efficiency and savings of this intervention through cost-effectiveness analysis.

Methods: MRI outpatient records from January to December 2020 (pre-intervention period) and January to December 2021 (post-intervention period) were retrospectively obtained from the hospital systems.

View Article and Find Full Text PDF

MRI is an important and widely used imaging modality for clinical diagnosis. This article provides a concise discussion of the basic principles of MRI physics for non-radiology clinicians, with a general explanation of the fundamentals of signal generation and image contrast mechanisms. Common pulse sequences, tissue suppression techniques and use of gadolinium contrast with relevant clinical applications are presented.

View Article and Find Full Text PDF

Objective: To evaluate the diagnostic value of the nanometer carbon suspension tracer staining technique in sentinel lymph node biopsy of breast cancer is the objective of this study.

Methods: The PubMed, Embase, Cochrane Library (Central), and Web of Science (SCI Expanded), and Chinese databases (CNKI, VIP, Wan Fang, and CBM) were systematically searched for studies on the diagnostic value of nanocarbon suspension in sentinel lymph node biopsy of breast cancer. Two reviewers independently assessed the methodological quality of each study using the QUADAS-2 tool.

View Article and Find Full Text PDF

CT is the imaging modality of choice for assessment of 3D bony morphology but incurs the penalty of ionizing radiation. Improving the ability of 3D MRI to provide high-resolution images of cortical bone with CT-like bone contrast has been a focus of recent research. The ability of 3D MRI to deliver cortical bone information with similar diagnostic performance to CT would complement assessment of soft tissues and medullary bone from a single MRI examination, simplifying evaluation and obviating radiation exposure from additional CT.

View Article and Find Full Text PDF

Bisphosphonates (BP) are the most commonly prescribed effective form of osteoporosis treatment with adverse effects associated with prolonged use such as atypical femoral fractures (AFF). Asians have an elevated risk of AFF at 5 to 6 times those of whites and Hispanics. In this study, we characterize factors associated with AFF and its mortality in a single center in Singapore.

View Article and Find Full Text PDF

Introduction: Studies show trabecular bone score (TBS) may provide information regarding bone quality independent of bone mineral density (BMD) in type 2 diabetes (DM2) patients. We analyzed our Southeast Asian severe osteoporotic hip fracture patients to study these differences.

Methods: We conducted a retrospective cross-sectional analysis of subjects admitted to Changi General Hospital, Singapore with severe osteoporotic hip fractures from 2014-2017 who had BMD performed.

View Article and Find Full Text PDF

Outpatient appointment no-shows are a common problem. Artificial intelligence predictive analytics can potentially facilitate targeted interventions to improve efficiency. We describe a quality improvement project that uses machine learning techniques to predict and reduce outpatient MRI appointment no-shows.

View Article and Find Full Text PDF

Unlabelled: A guide to the clinician on the use of dual-energy x-ray absorptiometry bone densitometry for the management of osteoporosis and the importance of recognizing its pitfalls.

Purpose: Osteoporosis is a major risk factor for severe fractures in the aging population worldwide, posing a serious public health issue. Dual-energy X-ray absorptiometry (DXA) is and remains the main tool for screening of osteoporosis and monitoring of osteoporosis treatment through quantitative measurement of bone mineral density (BMD).

View Article and Find Full Text PDF

Flow-independent relaxation-based non-contrast MR angiography techniques yield good signal-to-noise ratio and high blood-tissue contrast, complementing non-contrast flow-dependent and contrast-enhanced MR angiography techniques in the assessment of vascular disorders. However, these techniques often suffer from imaging artifacts at high magnetic field strengths or across large fields-of-view. Relaxation-Enhanced Angiography without Contrast and Triggering (REACT) is a recently introduced flow-independent non-gated non-contrast three-dimensional MR angiography technique that has been developed to mitigate some of these issues.

View Article and Find Full Text PDF

In this work we aimed to investigate the feasibility of using a new pulse sequence called Relaxation-Enhanced Angiography without Contrast and Triggering (REACT) for free-breathing non-contrast-enhanced MR angiography (NCE-MRA) for multiple anatomies on 3T. Two magnetization-preparation pulses were incorporated with a three-dimensional dual-echo Dixon sequence. A T2-prep pulse, followed by a non-selective inversion pulse with a short inversion time, together suppressed tissue with short T1 and T2, while enhancing the signal of native blood with long T1 and T2.

View Article and Find Full Text PDF

Cases of spontaneous tendon ruptures have been previously reported in the literature. Although both renal failure and hyperparathyroidism have been implicated as separate aetiologies, their frequent co-existence has confounded analysis. We report a case of a young man with primary hyperparathyroidism presenting with multiple acute spontaneous tendon ruptures.

View Article and Find Full Text PDF

Introduction: In this study, we aimed to compare the split-bolus and single-bolus computerised tomography (CT) urography and determine if this offers a reduction in radiation dose without compromising image quality.

Materials And Methods: A retrospective evaluation was performed on 88 patients undergoing split-bolus CT urography and this was compared to a control group of 101 consecutive patients undergoing single-bolus CT urography. A radiation dose analysis was performed on each subject.

View Article and Find Full Text PDF

Purpose: To review the errors made by radiology trainees in the reporting of cervical spine CTs (CCT) and to compare the discrepancy rates between the stages of training.

Methods: All CCTs reported by trainees after office hours between January 2015 and December 2015 were retrospectively reviewed by a team of five musculoskeletal consultants with experience ranging between 7 and 15 years. Discrepancies between the provisional report by the trainee and the findings by the musculoskeletal consultants were graded according to the RADPEER scoring system.

View Article and Find Full Text PDF

Extra-retinal, non-pineal, encephalic photoreceptors (EP) play important roles in mediating development of the reproductive system by the annual change in day length (photoperiodic gonadal response - PGR) in birds. However, the distribution of rhodopsin-like EPs and their functional daily, circadian and seasonal changes are still unclear in the avian brain. This study identifies two novel groups of rhodopsin-immunoreactive cells in the nucleus paraventricularis magnocellularis (PVN) of the hypothalamus and in the medial basal hypothalamus (MBH) in a seasonally breeding species, Gambel's white-crowned sparrow (Zonotrichia leucophrys gambelii).

View Article and Find Full Text PDF

Objective: Lister's tubercle is used as a standard anatomical landmark in hand surgery and arthroscopy procedures. In this study, we aimed to evaluate and propose a classification for anatomical variants of Lister's tubercle.

Materials And Methods: Between September 2011 and July 2014, 360 MRI examinations for wrists performed using 1.

View Article and Find Full Text PDF

Unlabelled: An increasing number of patients are being treated with cardiovascular implantable electronic devices (CIEDs), many of which are MR conditional. There is a lack of literature on the safe scanning of MR conditional CIEDs. This review article discusses MR imaging safety in patients with implanted CIEDs.

View Article and Find Full Text PDF

Purpose: To compare acetabular version angle measurements of CT scans in the prone and reformatted supine positions. CT acetabular version angle measurements have previously been done in the prone position to correct for pelvic tilt. With the advent of multidetector CT, recent studies have evaluated acetabular version angles measured in the supine position.

View Article and Find Full Text PDF

Purpose: Bone bruise represents an entity of occult bone lesions that can occur in the knee, causing knee pain and tenderness clinically. The aim of this study was to investigate the incidence and pattern of bone bruising seen in the anterior cruciate ligament (ACL) injury cohort, the non-ACL injury cohort, and between both cohorts.

Methods: We reviewed 710 knee magnetic resonance imagings performed over a 6-month period.

View Article and Find Full Text PDF

Background: Patellar Clunk Syndrome is a painful condition associated with a mechanical catching or clunking during active extension following total knee arthroplasty (TKA). The syndrome is caused by growth of interposing soft tissue usually at the superior pole of the patella. This interposed soft tissue cannot be visualized on plain radiographs.

View Article and Find Full Text PDF

Background: We performed this meta-analysis to assess the effectiveness and safety of axillary dissection in old women.

Methods: The Cochrane Library, PubMed, EMBASE and Chinese Biomedical Literature Database were searched and all randomized controlled trials of axillary dissection in old women (at least 60 years old) were considered. Meta-analyses were completed using RevMan5.

View Article and Find Full Text PDF

The seminal concept proposed by Sir Harold Himsworth more than 75 years ago that a large number of patients with diabetes were 'insulin insensitive', now termed insulin resistance, has now expanded to include several endocrine syndromes, namely those of glucocorticoid excess, and growth hormone excess and deficiency. Synthetic glucocorticoids are increasingly used to treat a wide variety of chronic diseases, whereas the beneficial effects of recombinant growth hormone replacement therapy in children and adults with growth hormone deficiency have now been well-recognized for over 25 years. However, clinical and experimental studies have established that increased circulating levels of glucocorticoids and growth hormone can also lead to worsening of insulin resistance, glucose intolerance, overt diabetes mellitus and cardiovascular disease.

View Article and Find Full Text PDF