Publications by authors named "Lawrence G Kettwich"

Purpose: Subcutaneous fat biopsy is useful for the evaluation of amyloidosis, environmental contaminants, lipid metabolism, genetic studies and diabetes research. The present study examined new technologies for fat biopsy.

Methods: Subcutaneous fat biopsy in 10 high-risk individuals was randomized to (i) a 10 ml reciprocating procedure device (RPD) mechanical syringe or (ii) a 60 ml vacuum syringe.

View Article and Find Full Text PDF

Objective: The present randomized controlled study investigated whether sonographic needle guidance affected the outcomes of intra-articular injection for osteoarthritis of the knee.

Methods: Ninety-four noneffusive knees with osteoarthritis were randomized to injection by conventional palpation-guided anatomic landmark injection or sonographic image-guided injection enhanced with a 1-handed mechanical (the reciprocating procedure device) syringe. After intra-articular placement and synovial space dilation were confirmed by sonography, a syringe exchange was performed, and 80 mg of triamcinolone acetonide was injected with the second syringe through the indwelling intra-articular needle.

View Article and Find Full Text PDF

Background: The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures.

Methods: The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe).

View Article and Find Full Text PDF

The purpose of this study was to determine whether the new reciprocating procedure device (RPD) is superior to the conventional syringe for the administration of local anesthesia. There were 209 local lidocaine anesthesia procedures randomized between the RDP and the conventional syringe. Outcome measures included administration time, anesthesia pain, procedure pain, and operator satisfaction.

View Article and Find Full Text PDF

Background: Greater than 50% of patients report significant pain with intraarticular injection of hyaluronate. The reciprocating procedure device (RPD), also known the reciprocating syringe, has 2 plungers that reciprocate with each other, permitting one-handed operation. The RPD increases physician control of the needle and is proposed to reduce patient pain during syringe procedures.

View Article and Find Full Text PDF

Objective: Injection of intraarticular corticosteroid remains an important therapy for inflammatory arthritis. In a randomized controlled trial we compared the new reciprocating procedure device (RPD) to the traditional syringe for injection of intraarticular corticosteroid.

Methods: One hundred fifty-four intraarticular corticosteroid injection procedures were randomized to the conventional syringe or the RPD.

View Article and Find Full Text PDF

Purpose: To determine the control and performance characteristics of eight different suction biopsy devices.

Materials And Methods: Physician control of the syringe and needle was measured precisely with the validated linear displacement method during the aspiration phase and during five biopsy passes. The visual analog scale was used to measure operator difficulty in the following domains: (i) attachment to the needle, (ii) generation of vacuum, (iii) detection of loss of vacuum, (iv) release of the vacuum, and (v) clearing of the sample from the needle.

View Article and Find Full Text PDF