In preparation for the International Society for Clinical Densitometry Position Development Conference (PDC) 2019 in Kuala Lumpur, Malaysia, a cross-calibration and precision task force was assembled and tasked to review the literature, summarize the findings, and generate positions to answer 4 related questions provided by the PDC Steering Committee, which expand upon the current ISCD official positions on these subjects. (1) How should a provider with multiple dual-energy X-ray absorptiometry (DXA) scanners of the same make and model calculate least significant change (LSC)? (2) How should a provider with multiple DXA systems with the same manufacturer but different models calculate LSC? (3) How should a provider with multiple DXA systems from different manufacturers and models calculate LSC? (4) Are there specific phantom procedures that one can use to provide trustworthy in vitro cross calibration for same models, different models, and different makes? Based on task force deliberations and the resulting systematic literature reviews, 3 new positions were developed to address these more complex scenarios not addressed by current official positions on single scanner cross calibration and LSC. These new positions provide appropriate guidance to large multiple DXA scanner providers wishing to offer patients flexibility and convenience, and clearly define good clinical practice requirements to that end.
View Article and Find Full Text PDFTo answer important questions in the fields of monitoring with densitometry, dual-energy X-ray absorptiometry machine cross-calibration, monitoring, spinal cord injury, periprosthetic and orthopedic bone health, transgender medicine, and pediatric bone health, the International Society for Clinical Densitometry (ISCD) held a Position Development Conference from March 20 to 23, 2019. Potential topics requiring guidance were solicited from ISCD members in 2017. Following that, a steering committee selected, prioritized, and grouped topics into Task Forces.
View Article and Find Full Text PDFA longer dual-energy X-ray absorptiometry scan field of the hip may be useful for the detection of atypical subtrochanteric femur fractures. It has been demonstrated in a Prodigy GE/Lunar scanner that extending the scan length does not affect bone mineral density (BMD) results at the total hip or femoral neck. We hypothesized that extending the scan field on a Hologic Discovery scanner would also have no effect on BMD results at the hip.
View Article and Find Full Text PDFThe 11th Santa Fe Bone Symposium was held in Santa Fe, NM, USA, on August 6-7, 2010. This annual event addresses the clinical relevance of recent scientific advances in the fields of osteoporosis and metabolic bone disease. The symposium format included plenary presentations, oral abstracts, and interactive panel discussions, with participation of clinicians, researchers, and bone densitometry technologists.
View Article and Find Full Text PDFThe International Society for Clinical Densitometry (ISCD) has developed Official Positions to assist healthcare providers in addressing some of the issues inherent with the use of bone mineral density (BMD) assessed by dual-energy X-ray absorptiometry (DXA) to diagnose osteoporosis, apply World Health Organization (WHO) T-score classifications, and monitor BMD changes over time. Differences exist, however, between the ISCD Official Position statement and that of the International Osteoporosis Foundation with respect to WHO criteria for skeletal sites. Consequently, a subcommittee of the ISCD was directed to address the application of the WHO classifications to specific skeletal sites and regions of interest.
View Article and Find Full Text PDF