The purpose of this study was to create a preliminary set of experimentally validated Finite Element Analysis (FEA) models, in order to predict the dynamic mechanical behaviour of human articular cartilage (AC). Current models consider static loading with limited independent experimental validation, while the models for this study assess dynamic loading of AC, with direct comparison and validation to physical testing. Three different FEA models of AC were constructed, which considered both linear elastic and hyperelastic models; Neo-Hookean and Ogden.
View Article and Find Full Text PDFDexmedetomidine is a selective alpha-2 adrenergic agonist utilized for sedation in critically ill patients. We present the case of a morbidly obese critically ill patient who experienced profound hyperthermia, with a maximum temperature of 41.4°C, hours after starting a dexmedetomidine infusion that was otherwise not explained by her clinical diagnoses.
View Article and Find Full Text PDFBackground: Articular cartilage is known to be a viscoelastic material, however little research has explored the impact of cartilage water content and bone density on its viscoelasticity. This study aimed to isolate subchondral bone density and hydration of articular cartilage and analyse their effects on the viscoelastic properties of articular cartilage.
Methods: Dynamic mechanical analysis was used to test samples at frequencies of 1, 8, 12, 29, 49, 71, and 88 Hz.
The aim of this study was to characterise the viscoelastic and hyper-elastic properties of the ulnar nerve before and after compression has been induced, in order to aid the understanding of how the mechanical properties of nerves are altered during nerve compression, a contributing factor to cubital tunnel syndrome. Ulnar nerves were dissected from porcine legs and tensile tested to 10% strain. The Young's modulus and Yeoh hyper-elastic model were used to evaluate the materials elastic and hyper-elastic properties respectively.
View Article and Find Full Text PDFThe aim of this study was to assess whether the mechanical properties of mitral valve chordae tendineae are sensitive to being cross-linked under load. A total 64 chordae were extracted from eight porcine hearts. Two chordae (posterior basal) from each heart were subjected to uniaxial ramp testing and six chordae (two strut, two anterior basal and two posterior basal) were subjected to dynamic mechanical analysis over frequencies between 0.
View Article and Find Full Text PDFThe aim of this study was to perform an initial assessment, in vitro, of the feasibility of using a glutaraldehyde cross-linked porcine mitral valve to retain acute functionality, focusing on assessing mitral regurgitation. Six porcine hearts were tested using an in vitro simulator. Testing was repeated following cross-linking of mitral valves; where cross-linking was achieved by placing them in a glutaraldehyde solution.
View Article and Find Full Text PDFObjective: To evaluate whether introduction of CCRTs reduced mortality rates among patients who developed a postoperative complication, also referred to as FTR.
Background: CCRTs were introduced to improve patients' postoperative outcomes. Its effect on FTR continues to be actively investigated.
Background: Despite it being known that subchondral bone affects the viscoelasticity of cartilage, there has been little research into the mechanical properties of osteochondral tissue as a whole system. This study aims to unearth new knowledge concerning the dynamic behaviour of human subchondral bone and how energy is transferred through the cartilage-bone interface.
Methods: Dynamic mechanical analysis was used to determine the frequency-dependent (1-90 Hz) viscoelastic properties of the osteochondral unit (cartilage-bone system) as well as isolated cartilage and bone specimens extracted from human femoral heads obtained from patients undergoing total hip replacement surgery, with a mean age of 78 years (N = 5, n = 22).
Background: Many survivors of stroke face chronic disability and increased risk for recurrent stroke. Regular physical activity can reduce these risk factors and improve cardiovascular fitness. Most survivors of stroke face barriers to exercise, including lack of access to programs; as a result, most are sedentary.
View Article and Find Full Text PDFObjective: Viscoelastic properties of articular cartilage have been characterised at physiological frequencies. However, studies investigating the interaction between cartilage and subchondral bone and the influence of underlying bone histomorphometry on the viscoelasticity of cartilage are lacking.
Method: Dynamic Mechanical Analysis (DMA) has been used to quantify the dynamic viscoelasticity of bovine tibial plateau osteochondral cores, over a frequency sweep from 1 to 88 Hz.
Cubital tunnel syndrome is the most prevalent neuropathy of the ulnar nerve and its aetiology is controversial. Potential replacement materials should display similar viscoelastic properties. The purpose of this study was to assess the feasibility and merit of quantifying the frequency-dependent viscoelastic properties of proximal and distal sections of the human ulnar nerve.
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
January 2019
The rise of antibiotic resistant bacterial species is driving the requirement for medical devices that minimise infection risks. Antimicrobial functionality may be achieved by modifying the implant design to incorporate a reservoir that locally releases a therapeutic. For this approach to be successful it is critical that mechanical functionality of the implant is maintained.
View Article and Find Full Text PDFUnlabelled: Osteoarthritis (OA) is a degenerative disease that affects 25% of the world's population over fifty years of age. It is a chronic disease of the synovial joints, primarily the hip and knee. The main pathologies are degradation of the articular cartilage and changes to the subchondral bone, as a result of both mechanical wear and a locally elevated inflammatory state.
View Article and Find Full Text PDFBackground: Mitral valve failure can require repair or replacement. Replacement bioprosthetic valves are treated with glutaraldehyde prior to implantation. The aim of this study was to determine the changes in mechanical properties following glutaraldehyde fixation of mitral valve chordae.
View Article and Find Full Text PDFUnlabelled: Hyperspectral chemical imaging (HCI) is an emerging technique which combines spectroscopy with imaging. Unlike traditional point spectroscopy, which is used in the majority of polymer biomaterial degradation studies, HCI enables the acquisition of spatially localised spectra across the surface of a material in an objective manner. Here, we demonstrate that attenuated total reflectance Fourier transform infra-red (ATR-FTIR) HCI reveals spatial variation in the degradation of implantable polycarbonate urethane (PCU) biomaterials.
View Article and Find Full Text PDFArticular cartilage is a viscoelastic tissue whose structural integrity is important in maintaining joint health. To restore the functionality of osteoarthritic joints it is vital that regenerative strategies mimic the dynamic loading response of cartilage and bone. Here, a rotating simplex model was employed to optimise the composition of agarose and gellan hydrogel constructs structured with hydroxyapatite (HA) with the aim of obtaining composites mechanically comparable to human cartilage in terms of their ability to dissipate energy.
View Article and Find Full Text PDFCracks can occur in the articular cartilage surface due to the mechanical loading of the synovial joint, trauma or wear and tear. However, the propagation of such cracks under different frequencies of loading is unknown. The objective of this study was to determine the effect of frequency of loading on the growth of a pre-existing crack in cartilage specimens subjected to cyclic tensile strain.
View Article and Find Full Text PDFThe aim of this study was to determine the effect of the induced stress and restraint provided by the underlying bone on the frequency-dependent storage and loss stiffness (for bone restraint) or modulus (for induced stress) of articular cartilage, which characterise its viscoelasticity. Dynamic mechanical analysis has been used to determine the frequency-dependent viscoelastic properties of bovine femoral and humeral head articular cartilage. A sinusoidal load was applied to the specimens and out-of-phase displacement response was measured to determine the phase angle, the storage and loss stiffness or modulus.
View Article and Find Full Text PDFThe transition from a pediatric to adult health care system is challenging for many youths with epilepsy and their families. Recently, the Ministry of Health and Long-Term Care of the Province of Ontario, Canada, created a transition working group (TWG) to develop recommendations for the transition process for patients with epilepsy in the Province of Ontario. Herein we present an executive summary of this work.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
April 2018
This study quantified the changes of the frequency-dependant viscoelastic properties of the BDyn (S14 Implants, Pessac, France) spinal posterior dynamic stabilization (PDS) device due to in vitro oxidation. Six polycarbonate urethane (PCU) rings and six silicone cushions were degraded using a 20% hydrogen peroxide/0.1 M cobalt (II) chloride hexahydrate, at 37°C, for 24 days.
View Article and Find Full Text PDFBackground: The purpose of this study was to compare the frequency-dependent viscoelastic properties of human and bovine cartilage.
Methods: Full-depth cartilage specimens were extracted from bovine and human femoral heads. Using dynamic mechanical analysis, the viscoelastic properties of eight bovine and six human specimens were measured over the frequency range 1 Hz to 88 Hz.
The urinary bladder is an organ which facilitates the storage and release of urine. The bladder can develop tumours and bladder cancer is a common malignancy throughout the world. There is a consensus that there are differences in the mechanical properties of normal and malignant tissues.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
June 2016
The purpose of this study was to quantify the frequency dependent viscoelastic properties of two types of spinal posterior dynamic stabilisation devices. In air at 37°C, the viscoelastic properties of six BDyn 1 level, six BDyn 2 level posterior dynamic stabilisation devices (S14 Implants, Pessac, France) and its elastomeric components (polycarbonate urethane and silicone) were measured using Dynamic Mechanical Analysis. The viscoelastic properties were measured over the frequency range 0.
View Article and Find Full Text PDF