A novel electrode anchoring design and its implantation procedure, aiming for a minimally invasive solution for gastric electrical stimulation, are presented. The system comprises an anchor made of a flexible body embedding two needle-shaped electrodes. The electrodes can easily switch from a parallel position - to pierce the stomach - to a diverging position - enabling them to remain firmly anchored into the muscular layer of the stomach.
View Article and Find Full Text PDFGastrointestinal stimulator implants have recently shown promising results in helping obese patients lose weight. However, to place the implant, the patient currently needs to undergo an invasive surgical procedure. We report a less invasive procedure to stimulate the stomach with a gastrostimulator.
View Article and Find Full Text PDFIn this document we discuss the main challenges encountered when producing flexible electrical stimulation implants, and present our approach to solving them for prototype production. We include a study of the optimization of the flexible PCB design, the selection of additive manufacturing materials for the mold, and the chemical compatibility of the different materials. Our approach was tested on a flexible gastro-stimulator as part of the ENDOGES research program.
View Article and Find Full Text PDFPower efficiency is critical for electrical stimulators. Battery life of wearable stimulators and wireless power transmission in implanted systems are common limiting factors. Boost DC/DC converters are typically needed to increase the supply voltage of the output stage.
View Article and Find Full Text PDFInductive powering of implantable medical devices involves numerous factors acting on the system efficiency and safety in adversarial ways. This paper lightens up their role and identifies a procedure enabling the system design. The latter enables the problem to be decoupled into four principal steps: the frequency choice, the magnetic link optimization, the secondary circuit and then finally the primary circuit designs.
View Article and Find Full Text PDFGastrointestinal stimulator implants have recently shown positive results in helping obese patients lose weight. However, to place the implant, the patient currently needs to undergo an invasive surgical procedure. Our team is aiming for a less invasive procedure to stimulate the stomach with a gastrostimulator.
View Article and Find Full Text PDFGastrointestinal stimulator implants have recently shown positive results in treating obesity. However, the implantation currently requires an invasive surgical procedure. Endoscopy could be used to place the gastric stimulator in the stomach, hence avoiding the riskier surgery.
View Article and Find Full Text PDFOne reason given for placing capacitors in series with stimulation electrodes is that they prevent direct current flow and therefore tissue damage under fault conditions. We show that this is not true for multiplexed multi-channel stimulators with one capacitor per channel. A test bench of two stimulation channels, two stimulation tripoles and a saline bath was used to measure the direct current flowing through the electrodes under two different single fault conditions.
View Article and Find Full Text PDF