The aim of this work was to determine heterogeneous correction factorshQclin,Qreffclin,frefdetm,wto validate absorbed dose-to-mediumDm,Qclinm,fclincalculation algorithms from detector readings. The impact of detector orientation perpendicular and parallel to the beam central axis on the correction factors was also investigated.ThehQclin,Qreffclin,frefdetm,wfactors were calculated for four types of detectors (PTW PinPoint T31016, PTW microDiamond T60019, PTW microSilicon T60023 and EBT3 film) placed in different media (cortical bone, lung, adipose tissue, Teflon and RW3) for the 6 MV energy beam with a 10 × 10 cmfield size.
View Article and Find Full Text PDFThe results of phase II and III trials on Stereotactic Body Radiation Therapy (SBRT) increased adoption of SBRT worldwide. The ability to replicate clinical trial outcomes in routine practice depends on the capability to reproduce technical and dosimetric procedures used in the clinical trial. In this systematic review, we evaluated if peer-reviewed publications of clinical trials in SBRT reported sufficient technical data to ensure safe and robust implementation in real world clinics.
View Article and Find Full Text PDFPurpose: To evaluate the impact of tuning the beam configurations parameters on the Analytical Anisotropic Algorithm (AAA) and the Acuros XB (AXB) algorithm for small fields using Monte Carlo simulations and measurements.
Methods: The TrueBeam STx with the high-definition 120 multi-leaf collimator (HD120-MLC) was modeled with Geant4 application for emission tomography (GATE) Monte Carlo platform and validated against measurements. The impact of varying the effective spot size (ESS) and dosimetric leaf gap (DLG) on AAA and AXB calculations was carried out for small MLC-fields ranging from 0.
Background: Glioblastoma (GBM) systematically recurs after a standard 60 Gy radio-chemotherapy regimen. Since magnetic resonance spectroscopic imaging (MRSI) has been shown to predict the site of relapse, we analyzed the effect of MRSI-guided dose escalation on overall survival (OS) of patients with newly diagnosed GBM.
Methods: In this multicentric prospective phase III trial, patients who had undergone biopsy or surgery for a GBM were randomly assigned to a standard dose (SD) of 60 Gy or a high dose (HD) of 60 Gy with an additional simultaneous integrated boost totaling 72 Gy to MRSI metabolic abnormalities, the tumor bed and residual contrast enhancements.
Purpose: To demonstrate the feasibility of characterising MLCs and MLC models implemented in TPSs using a common set of dynamic beams.
Materials And Methods: A set of tests containing synchronous (SG) and asynchronous sweeping gaps (aSG) was distributed among twenty-five participating centres. Doses were measured with a Farmer-type ion chamber and computed in TPSs, which provided a dosimetric characterisation of the leaf tip, tongue-and-groove, and MLC transmission of each MLC, as well as an assessment of the MLC model in each TPS.
The aim of this study was to determine field output correction factorskQclin,Qreffclin,frefand electron fluence perturbation for new PTW unshielded microSilicon and shielded microSilicon X detectors.kQclin,Qreffclin,freffactors were calculated for 6 and 10 MV with and without flattening filter beams delivered by a TrueBeam STx. Correction factors were determined for field sizes ranging from 0.
View Article and Find Full Text PDFPurpose: Monte Carlo (MC) is the reference computation method for medical physics. In radiotherapy, MC computations are necessary for some issues (such as assessing figures of merit, double checks, and dose conversions). A tool based on GATE is proposed to easily create full MC simulations of the Varian TrueBeam STx.
View Article and Find Full Text PDFPurpose: In modulated radiotherapy, breathing motion can lead to Interplay (IE) and Blurring (BE) effects that can modify the delivered dose. The aim of this work is to present the implementation, the validation and the use of an open-source Monte-Carlo (MC) model that computes the delivered dose including these motion effects.
Methods: The MC model of the Varian TrueBeam was implemented using GATE.
Purpose: To investigate (i) the dosimetric leaf gap (DLG) and the effect of the "trailing distance" between leaves from different multileaf collimator (MLC) layers in Halcyon systems and (ii) the ability of the currently available treatment planning systems (TPSs) to approximate this effect.
Methods: DICOM plans with transmission beams and sweeping gap tests were created in Python for measuring the DLG for each MLC layer independently and for both layers combined. In clinical Halcyon plans both MLC layers are interchangeably used and leaves from different layers are offset, thus forming a trailing pattern.
The benefits of using an algorithm that reports absorbed dose-to-medium have been jeopardized by the clinical experience and the experimental protocols that have mainly relied on absorbed dose-to-water. The aim of the present work was to investigate the physical aspects that govern the dosimetry in heterogeneous media using Monte Carlo method and to introduce a formalism for the experimental validation of absorbed dose-to-medium reporting algorithms. Particle fluence spectra computed within the sensitive volume of two simulated detectors (T31016 Pinpoint 3D ionization chamber and EBT3 radiochromic film) placed in different media (water, RW3, lung and bone) were compared to those in the undisturbed media for 6 MV photon beams.
View Article and Find Full Text PDFPurpose: This study aims at investigating the dosimetric characteristics of a Varian aS1000 EPID, focusing on its continuous acquisition mode under the challenging conditions that can be met in stereotactic radiotherapy verification.
Methods: An aS1000 EPID installed on a Varian TrueBeamSTx was irradiated with 6 and 10 MV unflattened and flattened photon beams. In order to avoid detector saturation, the source-to-detector distance (SDD) was set to 150 or 180 cm depending on the dose rate.
The method implemented in Monte Carlo (MC) algorithm to convert dose-to-medium (D ) to dose-to-water (D ) is usually based on the Bragg-Gray cavity theory. Acuros XB (AXB) reports also D and D but the method to calculate D is based on the energy deposition cross sections for water in place of those for the local media. For both algorithms, the calculation of D in non-water media is similar to the dose received in a small volume of water, small enough not to disturb the fluence of charged particles.
View Article and Find Full Text PDFThe dosimetric leaf gap (DLG) and tongue-and-groove (T&G) effects are critical aspects in the modeling of multileaf collimators (MLC) in the treatment planning system (TPS). In this study, we investigated the dosimetric impact of limitations associated with the T&G modeling in stereotactic plans and its relationship with the need for tuning the DLG in the Eclipse TPS. Measurements were carried out using Varian TrueBeam STx systems from two different institutions.
View Article and Find Full Text PDFBackground: Glioblastoma, a high-grade glial infiltrating tumor, is the most frequent malignant brain tumor in adults and carries a dismal prognosis. External beam radiotherapy (EBRT) increases overall survival but this is still low due to local relapses, mostly occurring in the irradiation field. As the ratio of spectra of choline/N acetyl aspartate> 2 (CNR2) on MR spectroscopic imaging has been described as predictive for the site of local relapse, we hypothesized that dose escalation on these regions would increase local control and hence global survival.
View Article and Find Full Text PDFCommercial TPSs typically model the tongue-and-groove (TG) by extending the projections of the leaf sides by a certain constant width. However, this model may produce discrepancies of as much as 7%-10% in the calculated average doses, especially for the High Definition multi-leaf collimator (MLC) (Hernandez et al 2017 Phys. Med.
View Article and Find Full Text PDFAdequate modelling of the multi-leaf collimator (MLC) by treatment planning systems (TPS) is essential for accurate dose calculations in intensity-modulated radiation-therapy. For this reason modern TPSs incorporate MLC characteristics such as the leaf end curvature, MLC transmission and the tongue-and-groove. However, the modelling of the tongue-and-groove is often neglected during TPS commissioning and it is not known how accurate it is.
View Article and Find Full Text PDFPurpose: Flattening filter free (FFF) beams are frequently used for stereotactic body radiation therapy with various treatment modalities: conventional static fields, dynamic conformal arc (DCA) or Rapid Arc (RA). The goal of this study was to obtain some criteria to enable a conscious choice of the employment of FFF beams and of the DCA or RA technique, depending on the PTV size.
Methods And Materials: 24 PTVs from 1.
The study of cell survival following exposure to nonuniform radiation fields is taking on particular interest because of the increasing evidence of a nonlinear relationship at low doses. We conducted in vitro experiments using the MCF7 breast cancer cell line. A 2.
View Article and Find Full Text PDFPurpose: To compare detectors for dosimetric verification before VMAT treatments and evaluate their sensitivity to errors.
Methods And Materials: Measurements using three detectors (ArcCheck, 2d array 729 and EPID) were used to validate the dosimetric accuracy of the VMAT delivery. Firstly, performance of the three devices was studied.
Aim: To investigate the feasibility of dose escalation using rapid arc (RA) and Helical Tomotherapy (HT) for patients with upper, middle and distal esophageal carcinomas, even for large tumor volumes.
Background: In esophageal cancer, for patients with exclusive radio-chemotherapy, local disease control remains poor. Planning study with dose escalation was done for two sophisticated modulated radiotherapy techniques: Rapid arc against Tomotherapy.
Background: To evaluate and compare dosimetric parameters of volumetric modulated arctherapy (VMAT) and helical tomotherapy (HT) for non-anaplastic thyroid cancer adjuvant radiotherapy.
Methods: Twelve patients with non-anaplastic thyroid cancer at high risk of local relapse received adjuvant external beam radiotherapy with curative intent in our institution, using a two-dose level prescription with a simultaneous integrated boost approach. Each patient was re-planned by the same physicist twice using both VMAT and HT.
Purpose: The purpose of this work was to retrospectively determine the value of intensity-modulated radiotherapy (IMRT) in patients with laryngeal and hypopharyngeal squamous cell carcinoma (LHSCC), on outcome and treatment-related toxicity compared to 3-dimensional conformal radiotherapy (3D-CRT).
Materials And Methods: A total of 175 consecutive patients were treated between 2007 and 2012 at our institution with curative intent RT and were included in this study: 90 were treated with 3D-CRT and 85 with IMRT. Oncologic outcomes were estimated using Kaplan-Meier statistics; acute and late toxicities were scored according to the Common Toxicity Criteria for Adverse Events scale v 3.
Background: To integrate 3D MR spectroscopy imaging (MRSI) in the treatment planning system (TPS) for glioblastoma dose painting to guide simultaneous integrated boost (SIB) in intensity-modulated radiation therapy (IMRT).
Methods: For sixteen glioblastoma patients, we have simulated three types of dosimetry plans, one conventional plan of 60-Gy in 3D conformational radiotherapy (3D-CRT), one 60-Gy plan in IMRT and one 72-Gy plan in SIB-IMRT. All sixteen MRSI metabolic maps were integrated into TPS, using normalization with color-space conversion and threshold-based segmentation.