Publications by authors named "Laura Rico"

Even though anti-PD-1/PD-L1 immune checkpoint inhibitors (ICIs) in non-small cell lung cancer (NSCLC) have improved survival, a high percentage of patients still do not respond to ICIs. Myeloid-derived suppressor cells (MDSCs) are circulating cells that express PD-L1 and can infiltrate and proliferate in the tumor microenvironment, inducing immunosuppression. By evaluating changes in PD-L1 expression of live peripheral blood MDSCs, we are able to define a new PD-L1 index, useful in predicting ICI escape in NSCLC patients before initiating anti-PD-1/PD-L1 immunotherapy.

View Article and Find Full Text PDF

To achieve high-sensitivity cell measurements (<1 in 10 cells) by flow cytometry (FCM), the minimum number of acquired cells must be considered and conventional immunophenotyping protocols fall short of these numbers. The bulk lysis (BL) assay is a standardized erythrocyte lysing approach that allows the analysis of the millions of cells required for high-sensitivity measurable residual disease (MRD) detection. However, this approach has been associated with significant cell loss, along with potential over or underestimates of rare cells when using this method.

View Article and Find Full Text PDF

Leukemic stem cells (LSCs) possess similar characteristics to normal hematopoietic stem cells, including self-renewal capacity, quiescence, ability to initiate leukemia, and drug resistance. These cells play a significant role in leukemia relapse, persisting even after apparent remission. LSCs were first described in 1994 by Lapidot et al.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluates a new volumetric counting method for CD34+ cells in blood samples, which aims to improve accuracy over traditional methods that use reference microbeads.
  • The issue with the "vanishing counting bead phenomenon" affects the reliability of results obtained with bead-based systems but has been addressed through the development of a true volumetric counting system.
  • Results showed no significant difference in CD34+ cell counts between volumetric and non-volumetric methods, suggesting that the new volumetric technique could simplify sample preparation and reduce analysis bias.
View Article and Find Full Text PDF

The programmed cell death protein 1/programmed cell death protein ligand 1 (PD-1/PD-L1) axis is one of the most widely recognized targets for cancer immunotherapy. Importantly, PD-L1 conformational changes can hinder target binding when living cells are used. Antibody affinity, equilibrium binding, association and dissociation rates, and other affinity-related constants are fundamental to ensure target saturation.

View Article and Find Full Text PDF

Background: The morbidity of early-term newborns (ETNBs) is associated with the immaturity of their organs and maternal biological factors (MBF). In this study, we determined the relationship between MBF and early-term birth. In addition, we assessed the role of gestational age (GA) and MBF in the morbidity of ETNBs compared with full-term newborns (FTNBs).

View Article and Find Full Text PDF

Plastic pollution is a global problem. Animals and humans can ingest and inhale plastic particles, with uncertain health consequences. Nanoplastics (NPs) are particles ranging from 1 nm to 1000 nm that result from the erosion or breakage of larger plastic debris, and can be highly polydisperse in physical properties and heterogeneous in composition.

View Article and Find Full Text PDF

Flow cytometry (FCM) enumeration of peripheral blood dendritic cells (PBDCs) is a minimally invasive procedure extremely useful for immunological studies. Numbers of PBDCs vary depending on age, lifestyle, or in pathologies like cancer, leukemia or immunodeficiencies. Conventional methods for PBDC identification by FCM involve red blood cell lysis using either formaldehyde or ammonium chloride-based solutions.

View Article and Find Full Text PDF

Doublet discrimination is usually based on pulse analysis of light scatter parameters. A combination of two pulse parameters (Area, A; Height, H; or Width, W) can be used to discriminate a pulse originated in a single cell from a pulse originated from cells stuck together. Fluorescence signals can be also used to discriminate aggregates, being essential to identify cells in the G2/M phase from doublets in the G0/G1 phase in cell cycle/DNA applications.

View Article and Find Full Text PDF

The challenges associated with analyzing rare cells are dependent on a series of factors, which usually require large numbers of cells per sample for successful resolution. Among these is determining the minimum number of total events needed to be acquired as defined by the expected frequency of the target cell population. The choice of markers that identify the target population, as well as the event rate and the number of aborted events/second, will also determine the statistically significant detection of rare cell events.

View Article and Find Full Text PDF

Immune activation is one of the most common complications during pregnancy, predominantly evoked by viral infections. Nevertheless, how immune activation affects mother-offspring relationships postpartum remains unknown. Here, by using the polyinosinic-polycytidylic acid (Poly I:C) model of gestational infection we show that viral-like immune activation at mid-gestation persistently changes hypothalamic neurocircuit parameters in mouse dams and, consequently, is adverse to parenting behavior.

View Article and Find Full Text PDF

Clinical Relevance: It is important to distinguish between visual acuity, optical quality and quality of vision when outcomes obtained with intraocular lenses are evaluated. These parameters, that includeobjective and subjective tests, should be assessed to obtain results that are not biased.

Background: To assess the difference in visual and optical quality between two monofocal intraocular lens models.

View Article and Find Full Text PDF

This protocol provides instructions to improve flow cytometry analysis of marrow/peripheral blood cells by avoiding erythrolytic solutions, density gradients, and washing steps. We describe two basic approaches for identifying cell surface antigens with minimal sample perturbation, which have been successfully used to identify healthy and pathologically rare cells. The greatest advantage of these approaches is that they minimize the unwanted effect caused by sample preparation, allowing for improved study of live cells at the point of analysis.

View Article and Find Full Text PDF

Current methods for the determination of cell-mediated cytotoxic activity in blood samples usually isolate peripheral blood mononuclear cells by density gradient centrifugation or alternatively use erythrocyte lysis. Both centrifugation and red cell lysis can cause cellular depletion and cell dysfunction, resulting in erroneous measurements. To address limitations of current assays, we developed an improved strategy to determine cellular cytotoxicity using flow cytometry.

View Article and Find Full Text PDF

• PD-L1 displays variation of spatial conformation in response to phorbol ester stimulation, which may confer a critical enhancement in binding affinity. • PD-L1 conformational change may be associated with an immunoregulatory mechanism that affects therapies targeting the PD-1/PD-L1 checkpoint. • Eliminating MDSCs by promoting PD-L1 stabilized unfolded states on both PMN- and M-MDSCs could improve immunotherapy efficacy.

View Article and Find Full Text PDF

Purpose: To compare clinical outcomes in a prospective trial of cataract surgery patients bilaterally implanted with two different trifocal intraocular lenses (IOLs) with very similar optical designs but consisting of different IOL materials (hydrophobic and hydrophilic).

Patients And Methods: Fifty-one patients (102 eyes) were randomized to receive trifocal IOLs bilaterally - FineVision POD F (hydrophilic) or FineVision POD F GF (hydrophobic) (both PhysIOL, Liége, Belgium). The follow-up period was 3 months.

View Article and Find Full Text PDF

Introduction: Pre-analytical and analytical errors can threaten the reliability of flow cytometry (FC) results. A potential solution to some of these is the use of dry, pre-mixed antibodies, such as the ClearLLab 10C system. The purpose of the present study was to compare the diagnostic performance of the ClearLLab 10C B cell tube with that of our standard laboratory practice.

View Article and Find Full Text PDF

For several decades, cell-mediated cytotoxicity has been measured using the Cr release assay. This assay, however, has several drawbacks and flow cytometry has been used as an alternative to measure cytotoxic activity. Here, we present a quantitative method for cell-mediated cytotoxicity studies, preserving cellular function with minimal sample manipulation.

View Article and Find Full Text PDF

Translational research has improved the diagnosis and follow-up of hematological diseases and malignancies. However, some classical diagnostics used for research and clinical practice that have remain practically unchanged for decades may be better addressed through advances in flow cytometry technology, whereby more precise measurements may be implemented in a straightforward manner. The current method for semiquantitative analysis of granulocytic alkaline phosphatase (GAP) activity is still based on observer-dependent color-intensity classification.

View Article and Find Full Text PDF

In this prospective hospital-based cohort study that included 43 newly diagnosed patients with acute myeloid leukemia, flow cytometric cellular alkaline phosphatase (ALP) activity within primitive leukemic cells allowed us to identify two groups of patients at diagnosis according to the numbers of leukemic blasts expressing ≥ 12% of ALP+ cells (27 patients, Group A) and less than 12% of ALP+ cells (16 patients, Group B). Differences in outcome for complete response, relapse or treatment resistance, and exitus were statistically analyzed and were significant, when comparing the two groups. The overall survival (OS) and event-free survival (EFS) differences between Group A and B were statistically significant.

View Article and Find Full Text PDF

These guidelines are a consensus work of a considerable number of members of the immunology and flow cytometry community. They provide the theory and key practical aspects of flow cytometry enabling immunologists to avoid the common errors that often undermine immunological data. Notably, there are comprehensive sections of all major immune cell types with helpful Tables detailing phenotypes in murine and human cells.

View Article and Find Full Text PDF

Fabry disease is a rare X-linked disorder caused by an alpha-galactosidase enzyme deficiency, which leads to a progressive lysosomal glycosphingolipids accumulation, mainly globotriaosylceramide, in multiple organism tissues including the eye. This case series describes the first ophthalmological Colombian report of Fabry disease highlighting the importance of ocular signs as markers of the disease, useful in diagnosis and treatment to avoid long-term complications that lead to a morbi-mortality increment. We describe five cases of Fabry disease from Bogotá, Colombia, including a complete clinical history, ophthalmologic, optometric examination, and photographs.

View Article and Find Full Text PDF

The Mediterranean Diet (MedDiet) has been promoted as a means of preventing and treating cardiodiabesity. The aim of this study was to answer a number of key clinical questions (CQs) about the role of the MedDiet in cardiodiabesity in order to provide a framework for the development of clinical practice guidelines. A systematic review was conducted to answer five CQs formulated using the Patient, Intervention, Comparison, and Outcome (PICO) criteria.

View Article and Find Full Text PDF

Background/objectives: The primary objective of this study was to explore physicians' adherence to the dietary pattern known as the Mediterranean diet (MD). As a secondary objective we assessed physicians' awareness on the benefits of the MD and of the possibility of prescribing it.

Subjects/methods: Physicians' adherence to the MD was evaluated through the Spanish associations SEMERGEN and CAMFIC, who sent the validated PREDIMED screener to their affiliates.

View Article and Find Full Text PDF