Background: Non-invasive online fluorescence monitoring in high-throughput microbioreactors is a well-established method to accelerate early-stage bioprocess development. Recently, single-wavelength fluorescence monitoring in microtiter plates was extended to measurements of highly resolved 2D fluorescence spectra, by introducing charge-coupled device (CCD) detectors. Although introductory experiments demonstrated a high potential of the new monitoring technology, an assessment of the capabilities and limits for practical applications is yet to be provided.
View Article and Find Full Text PDFCAR-T cell therapy is a promising treatment for acute leukemia and lymphoma. CAR-T cell therapies take a pioneering role in autologous gene therapy with three EMA-approved products. However, the chance of clinical success remains relatively low as the applicability of CAR-T cell therapy suffers from long, labor-intensive manufacturing and a lack of comprehensive insight into the bioprocess.
View Article and Find Full Text PDFAdvanced Therapy Medicinal Products (ATMP) provide promising treatment options particularly for unmet clinical needs, such as progressive and chronic diseases where currently no satisfying treatment exists. Especially from the ATMP subclass of Tissue Engineered Products (TEPs), only a few have yet been translated from an academic setting to clinic and beyond. A reason for low numbers of TEPs in current clinical trials and one main key hurdle for TEPs is the cost and labor-intensive manufacturing process.
View Article and Find Full Text PDFGiven its geometric similarity to large-scale production plants and the excellent possibilities for precise process control and monitoring, the classic stirred tank bioreactor (STR) still represents the gold standard for bioprocess development at a laboratory scale. However, compared to microbioreactor technologies, bioreactors often suffer from a low degree of process automation and deriving key performance indicators (KPIs) such as specific rates or yields often requires manual sampling and sample processing. A widely used parallelized STR setup was automated by connecting it to a liquid handling system and controlling it with a custom-made process control system.
View Article and Find Full Text PDFWith the utilization of small-scale and highly parallelized cultivation platforms embedded in laboratory robotics, microbial phenotyping and bioprocess development have been substantially accelerated, thus generating a bottleneck in bioanalytical bioprocess sample analytics. While microscale cultivation platforms allow the monitoring of typical process parameters, only limited information about product and by-product formation is provided without comprehensive analytics. The use of liquid chromatography mass spectrometry can provide such a comprehensive and quantitative insight, but is often limited by analysis runtime and throughput.
View Article and Find Full Text PDFHigh-performance anion exchange chromatography coupled to pulsed amperometric detection (HPAEC-PAD) was used for developing a method for identifying and quantifying aldehydes in biomass hydrolyzates. This method was optimized to the requirements of HPAEC-PAD in order to allow for a simultaneous determination of aldehydes by respective Cannizzaro alcohols. To this end, sodium hydroxide concentration (0.
View Article and Find Full Text PDFFew behavioral parent training (BPT) treatment studies for attention-deficit/hyperactivity disorder (ADHD) have included and measured outcomes with fathers. In this study, fathers were randomly assigned to attend a standard BPT program or the Coaching Our Acting-Out Children: Heightening Essential Skills (COACHES) program. The COACHES program included BPT plus sports skills training for the children and parent-child interactions in the context of a soccer game.
View Article and Find Full Text PDFBehavioral parent training is an efficacious treatment for attention-deficit/hyperactivity disorder (ADHD). However, single-mother households are at high risk for poor outcomes during and following behavioral parent training. This study randomly assigned cohorts of 120 single mothers of children (ages 5-12 years) with ADHD to a waitlist control group, a traditional behavioral parent training program, or an enhanced behavioral parent training program -- the Strategies to Enhance Positive Parenting (STEPP) program.
View Article and Find Full Text PDFObjective: The Strategies to Enhance Positive Parenting (STEPP) program was developed to address putative factors related to poor engagement in and outcomes following traditional behavioral parent training (BPT) for single mothers of children diagnosed with ADHD.
Method: Twelve single mothers of children with ADHD were enrolled in an initial investigation of the feasibility and preliminary efficacy of the 9-week STEPP program.
Results: Results indicated that the STEPP program was effective in reducing problematic child behavior and improving parental stress and psychopathology at posttreatment.