Background: Patients with syndromic heritable thoracic aortic diseases (sHTAD) who underwent prophylactic aortic root replacement are at high risk of distal aortic events, but the underlying mechanisms remain unclear. This prospective, longitudinal study evaluates the impact of valve-sparing aortic root replacement (VSARR) on aortic fluid dynamics and biomechanics in these patients.
Methods: Sixteen patients with Marfan or Loeys-Dietz syndrome underwent two time-resolved three-dimensional phase-contrast cardiovascular magnetic resonance (4D flow CMR) studies before (sHTAD-preSx) and after VSARR (sHTAD-postSx).
Background: Longitudinal data on reverse cardiac remodeling and outcomes after transcatheter edge-to-edge repair (TEER) are limited.
Methods: A total of 78 patients with severe mitral regurgitation (MR) were included retrospectively. All patients had echocardiography at baseline and again six months after TEER.
Objective: Concerns exist about the possible detrimental effects of exercise training on aortic size and valve function in individuals with bicuspid aortic valve (BAV). This multicentre international study aimed to determine the characteristics of aortic size and valve function in athletes versus non-athletes with BAV and athletes with tricuspid aortic valve (TAV).
Methods: We enrolled competitive athletes with BAV and age- and sex-matched athletes with TAV and non-athletes with BAV.
Background: Aortic stenosis (AS) is characterized by calcification and fibrosis. The ability to quantify these processes simultaneously has been limited with previous imaging methods.
Objectives: The purpose of this study was to evaluate the aortic valve fibrocalcific volume by computed tomography (CT) angiography in patients with AS, in particular, to assess its reproducibility, association with histology and disease severity, and ability to predict/track progression.
Background: Clinical outcomes of bicuspid aortic valve (BAV) patients with ascending aortic diameters ≥50 mm who are under surveillance are poorly defined.
Objectives: The purpose of this study was to assess clinical outcomes in BAV patients with ascending aorta ≥50 mm.
Methods: Multicenter retrospective cohort study of BAV adults with ascending aorta diameters ≥50 mm by transthoracic echocardiography (TTE).
Purpose To use unsupervised machine learning to identify phenotypic clusters with increased risk of arrhythmic mitral valve prolapse (MVP). Materials and Methods This retrospective study included patients with MVP without hemodynamically significant mitral regurgitation or left ventricular (LV) dysfunction undergoing late gadolinium enhancement (LGE) cardiac MRI between October 2007 and June 2020 in 15 European tertiary centers. The study end point was a composite of sustained ventricular tachycardia, (aborted) sudden cardiac death, or unexplained syncope.
View Article and Find Full Text PDFBackground: Ascending aorta dilation and aortic valve degeneration are common complications in patients with bicuspid aortic valve. Several retrospective studies have suggested the benefit of statins in reducing these complications. This study aimed to determine whether atorvastatin treatment is effective in reducing the growth of aortic diameters in bicuspid aortic valve and if it slows the progression of valve calcification.
View Article and Find Full Text PDFIntroduction And Purpose: Bicuspid aortic valve (BAV) disease is associated with faster aortic valve degeneration and a high incidence of aortic stenosis (AS). In this study, we aimed to identify differences in the pathophysiology of AS between BAV and tricuspid aortic valve (TAV) patients in a multiomics study integrating metabolomics and transcriptomics as well as clinical data.
Methods: Eighteen patients underwent aortic valve replacement due to severe aortic stenosis: 8 of them had a TAV, while 10 of them had a BAV.
J Cardiovasc Magn Reson
June 2024
Background: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate.
View Article and Find Full Text PDFObjectives: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus.
View Article and Find Full Text PDFBicuspid aortic valve is the most common congenital heart disease and exposes patients to an increased risk of aortic dilation and dissection. Aortic dilation is a slow, silent process, leading to a greater risk of aortic dissection. The prevention of adverse events together with optimization of the frequency of the required lifelong imaging surveillance are important for both clinicians and patients and motivated extensive research to shed light on the physiopathologic processes involved in bicuspid aortic valve aortopathy.
View Article and Find Full Text PDFBackground: Blunt traumatic thoracic aortic injuries (BTAIs) are associated with a high mortality rate. Thoracic endovascular aortic repair (TEVAR) is the most frequently used surgical strategy in patients with BTAI, as it offers good short- and middle-term results. Previous studies have reported an abnormally high prevalence of hypertension (HT) in these patients.
View Article and Find Full Text PDFObjectives: To describe the aortic-related risks associated with pregnancy in women with bicuspid aortic valve (BAV) and to evaluate changes in aortic diameter in pregnancy.
Methods: Prospective observational study of patients with BAV from a single-site registry of pregnant women with structural heart disease between 2013 and 2020. Cardiac, obstetric and neonatal outcomes were studied.
Aims: To assess the progression of the disease and evolution of the main echocardiographic variables for quantifying AS in patients with severe low-flow low-gradient (LFLG) AS compared to other severe AS subtypes.
Methods And Results: Longitudinal, observational, multicenter study including consecutive asymptomatic patients with severe AS (aortic valve area, AVA < 1.0 cm²) and normal left ventricle ejection fraction (LVEF ≥ 50%).
Introduction: The bicuspid aortic valve (BAV) confers a high risk of ascending aorta dilatation (AAoD), although its progression seems highly variable. Furthermore, the implication of lipoprotein metabolism and inflammation in the mechanisms that underlie AAoD is not fully established. The aim of this study consisted of evaluating the impact of the lipoprotein and glycoprotein profiles in AAOD as well as its progression in BAV aortopathy.
View Article and Find Full Text PDFBackground: Significant (moderate or greater) mitral regurgitation (MR) could augment the hemodynamic effects of aortic valvular disease in patients with bicuspid aortic valve (BAV), imposing a greater hemodynamic burden on the left ventricle and atrium, possibly culminating in a faster onset of left ventricular dilation and/or symptoms. The aim of this study was to determine the prevalence and prognostic implications of significant MR in patients with BAV.
Methods: In this large, multicenter, international registry, a total of 2,932 patients (mean age, 48 ± 18 years; 71% men) with BAV were identified.
Background: The prognostic impact of left ventricular ejection fraction (LVEF) in patients with bicuspid aortic valve (BAV) disease has not been previously studied.
Objectives: The purpose of this study was to determine the prognostic impact of LVEF in BAV patients according to the type of aortic valve dysfunction.
Methods: We retrospectively analyzed the data collected in 2,672 patients included in an international registry of patients with BAV.
Objectives: To determine the risk of mortality and need for aortic valve replacement (AVR) in patients with low-flow low-gradient (LFLG) aortic stenosis (AS).
Methods: A longitudinal multicentre study including consecutive patients with severe AS (aortic valve area [AVA] < 1.0 cm) and normal left ventricular ejection fraction (LVEF).
J Cardiovasc Magn Reson
March 2022
Background: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD.
View Article and Find Full Text PDFMultimodality imaging is the basis of the diagnosis, follow-up, and surgical management of bicuspid aortic valve (BAV) patients. Transthoracic echocardiography (TTE) is used in our clinical routine practice as a first line imaging for BAV diagnosis, valvular phenotyping and function, measurement of thoracic aorta, exclusion of other aortic malformations, and for the assessment of complications such are infective endocarditis and aortic. Nevertheless, TTE is less useful if we want to assess accurately other aortic segments such as mid-distal ascending aorta, where computed tomography (CT) and magnetic resonance (CMR) could improve the precision of aorta size measurement by multiplanar reconstructions.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
November 2022
Aims: Characterization of left ventricular (LV) geometric pattern and LV mass could provide an important insight into the pathophysiological adaptations of the LV to pressure and/or volume overload in patients with bicuspid aortic valve (BAV) and significant (≥moderate) aortic valve (AV) disease. This study aimed to characterize LV remodelling and its prognostic impact in patients with BAV according to the predominant type of valvular dysfunction.
Methods And Results: In this international, multicentre BAV registry, 1345 patients [51.