High-contrast gratings (HCG) are an excellent candidate for label-free detection of various kinds of biomarkers because they exhibit sharp and sensitive optical resonances. In this work, we experimentally show the performance of pedestal HCG (PHCG), which is significantly enhanced in comparison with that of conventional HCG. PCHGs were found to provide a 11.
View Article and Find Full Text PDFLow-energy (80-300 keV) electron beam accelerators are gaining in importance in the radiation processing industry due to their ease of use and wide range of applications (e.g. product surface sterilizations or polymer curing and cross-linking).
View Article and Find Full Text PDFMethods Appl Fluoresc
November 2016
Photodynamic diagnosis (PDD) of bladder tumour tissue significantly improves endoscopic diagnosis and treatment of bladder cancer in rigid cystoscopes in the operating theatre and thus reduces tumour recurrence. PDD comprises the use of blue light, which unfortunately excites green fluorescence from urine. As this green fluorescence confounds the desired red fluorescence of the PDD, methods for avoiding this situation particularly in cystoscopy using flexible cystoscopes are desirable.
View Article and Find Full Text PDFBackground And Objective: Frequent recurrence of non-muscle invasive bladder tumours (NMIBC) requiring transurethral resection of bladder tumour (TUR-BT) and lifelong monitoring makes the lifetime cost per patient the highest of all cancers. A new method is proposed for the removal of low grade NMIBCs in an office-based setting, without the need for sedation and pain control and where the patient can leave immediately after treatment.
Study Design/patients And Methods: An in vitro model was developed to examine the dose/response relationship between laser power, treatment time, and distance between laser fibre and target, using a 980 nm diode laser and chicken meat.
A fast-readout dosimetry system based on fibre-coupled organic scintillators has been developed for the purpose of conducting point measurements of absorbed dose in radiotherapy beams involving high spatial and temporal dose gradients. The system measures the dose for each linac radiation pulse with millimetre spatial resolution. To demonstrate the applicability of the system in complex radiotherapy fields, output factors and per cent depth dose measurements were performed in solid water for a 6 MV photon beam and compared with Monte Carlo simulated doses for square fields down to 0.
View Article and Find Full Text PDF