Single-photon emission computed tomography (SPECT) with pinhole collimators can provide high-resolution imaging, but is often limited by low sensitivity. Acquiring projections simultaneously through multiple pinholes affords both high resolution and high sensitivity. However, the overlap of projections from different pinholes on detectors, known as multiplexing, has been shown to cause artefacts which degrade reconstructed images.
View Article and Find Full Text PDFIt has been reported that hyaluronic acid (HA) with a 35 kDa molecular weight (HA35) acts biologically to protect tissue from injury, but its biological properties are not yet fully characterized. This study aimed to evaluate the cellular effects and biodistribution of HA35 compared to HA with a 1600 kDa molecular weight (HA1600). We assessed the effects of HA35 and HA1600 on cell migration, NO and ROS generation, and gene expression in cultured macrophages, microglia, and lymphocytes.
View Article and Find Full Text PDFMyocardial infarction (MI) triggers adverse ventricular remodeling (VR), cardiac fibrosis, and subsequent heart failure. Extracellular nicotinamide phosphoribosyltransferase (eNAMPT) is postulated to play a significant role in VR processing via activation of the TLR4 inflammatory pathway. We hypothesized that an eNAMPT specific monoclonal antibody (mAb) could target and neutralize overexpressed eNAMPT post-MI and attenuate chronic cardiac inflammation and fibrosis.
View Article and Find Full Text PDFBiomed Phys Eng Express
December 2023
The Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, featuring a static cardio focus asymmetrical geometry enabling simultaneous high-resolution and high-sensitivity imaging. Among 14 design iterations of the DC-SPECT with varying number of detector heads, system sensitivity and resolution, the current version under development features 10 mm FWHM geometrical resolution (without resolution recovery) and 0.07% sensitivity at the center of the FOV, this is 1.
View Article and Find Full Text PDFPurpose: To evaluate the yttrium-90 (Y) activity distribution in biopsy tissue samples of the treated liver to quantify the dose with higher spatial resolution than positron emission tomography (PET) for accurate investigation of correlations with microscopic biological effects and to evaluate the radiation safety of this procedure.
Materials And Methods: Eighty-six core biopsy specimens were obtained from 18 colorectal liver metastases (CLMs) immediately after Y transarterial radioembolization (TARE) with either resin or glass microspheres using real-time Y PET/CT guidance in 17 patients. A high-resolution micro-computed tomography (micro-CT) scanner was used to image the microspheres in part of the specimens and allow quantification of Y activity directly or by calibrating autoradiography (ARG) images.
Monte-Carlo simulation studies have been essential for advancing various developments in single photon emission computed tomography (SPECT) imaging, such as system design and accurate image reconstruction. Among the simulation software available, Geant4 application for tomographic emission (GATE) is one of the most used simulation toolkits in nuclear medicine, which allows building systems and attenuation phantom geometries based on the combination of idealized volumes. However, these idealized volumes are inadequate for modeling free-form shape components of such geometries.
View Article and Find Full Text PDFUnlabelled: Acute respiratory distress syndrome (ARDS) is accompanied by a dramatic increase in lung hyaluronic acid (HA), leading to a dose-dependent reduction of pulmonary oxygenation. This pattern is associated with severe infections, such as COVID-19, and other important lung injury etiologies. HA actively participates in molecular pathways involved in the cytokine storm of COVID-19-induced ARDS.
View Article and Find Full Text PDFMol Imaging Biol
February 2023
Purpose: Previous studies indicate that Tc- and fluorescent-labeled c[Cys-Thr-Pro-Ser-Pro-Phe-Ser-His-Cys]OH (TCP-1) peptides were able to detect colorectal cancer (CRC) and tumor-associated vasculature. This study was designed to characterize the targeting properties of PEGylated and non-PEGylated TCP-1 peptides for CRC imaging.
Procedures: Cell uptake of cyanine 7 (Cy7)-labeled TCP-1 probes (Cy7-PEG-TCP-1 and Cy7-TCP-1) was investigated in three CRC cell lines (human, HCT116 and HT29; mouse, CT26).
SPECT imaging of dopamine transporters (DAT) in the brain is a widely utilized study to improve the diagnosis of Parkinsonian syndromes, where conventional (parallel-hole and fan-beam) collimators on dual-head scanners are commonly employed. We have designed a multi-pinhole (MPH) collimator to improve the performance of DAT imaging. The MPH collimator focuses on the striatum and hence offers a better trade-off for sensitivity and spatial resolution than the conventional collimators within this clinically most relevant region for DAT imaging.
View Article and Find Full Text PDFApplication of multi-pinhole collimator in pinhole-based SPECT increases detection sensitivity. The presence of multiplexing in projection images due to the usage of multiple pinholes can further improve the sensitivity at the cost of adding data ambiguity. We are developing a next-generation adaptive brain-dedicated SPECT system -AdaptiSPECT-C.
View Article and Find Full Text PDFWe are developing a multi-detector pinhole-based stationary brain-dedicated SPECT system: AdaptiSPECT-C. In this work, we introduced a new design prototype with multiple adaptable pinhole apertures for each detector to modulate the multiplexing by employing temporal shuttering of apertures. Temporal shuttering of apertures over the scan time provides the AdaptiSPECT-C with the capability of multiple-frame acquisition.
View Article and Find Full Text PDFWith brain-dedicated multi-detector systems employing pinhole apertures the usage of detectors facing the top of the patient's head (i.e. quasi-vertex (QV) views) can provide the advantage of additional viewing from close to the brain for improved detector coverage.
View Article and Find Full Text PDFWe designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-spatial-resolution static imaging. The current system design consists of 23 detector heads arranged in a truncated spherical geometry.
View Article and Find Full Text PDFIn this work, we explore deep learning based techniques using the information from mean detector response functions (MDRFs) as a new method to estimate gamma ray interaction location in monolithic scintillation crystal detectors. Compared with searching based methods, deep learning techniques do not require recording all the MDRF information once the prediction networks are trained, which means the memory cost could be significantly reduced. In addition, the event positioning process using deep learning techniques only requires running through the network once, without the need to do searching in the reference dataset.
View Article and Find Full Text PDFMulti-pinhole (MPH) collimators are known to provide better trade-off between sensitivity and resolution for preclinical, as well as for smaller regions in clinical SPECT imaging compared to conventional collimators. In addition to this geometric advantage, MPH plates typically offer better stopping power for penetration than the conventional collimators, which is especially relevant for I-123 imaging. The I-123 emits a series of high-energy (>300 keV, ~2.
View Article and Find Full Text PDFWe have developed a fast gamma-ray interaction-position estimation method using k-d tree search, which can be combined with various kinds of closeness metrics such as Euclidean distance, maximum-likelihood estimation, etc. Compared with traditional search strategies, this method can achieve both speed and accuracy at the same time using the k-d tree data structure. The k-d tree search method has a time complexity of [Formula: see text], where N is the number of entries in the reference data set, which means large reference datasets can be used to efficiently estimate each event's interaction position.
View Article and Find Full Text PDFIntroduction: The objective of this study was to investigate the cardioprotective effects of a dodecafluoropentane (DDFP)-based perfluorocarbon emulsion (DDFPe) as an artificial carrier for oxygen delivery to ischemic myocardium, using Tc-duramycin SPECT imaging.
Methods: Rat hearts with Ischemia-reperfusion (I/R) was prepared by coronary ligation for 45-min followed by reperfusion. The feasibility of Tc-duramycin in detecting myocardial I/R injury and its kinetic profile were first verified in the ischemic hearts with 2-h reperfusion (n = 6).
Superparamagnetic iron oxide nanoparticles with well-integrated multimodality imaging properties have generated increasing research interest in the past decade, especially when it comes to the targeted imaging of tumors. Bevacizumab (BCZM) on the other hand is a well-known and widely applied monoclonal antibody recognizing VEGF-A, which is overexpressed in angiogenesis. The aim of this proof-of-concept study was to develop a dual-modality nanoplatform for targeted single photon computed emission tomography (SPECT) and magnetic resonance imaging (MRI) of tumor vascularization.
View Article and Find Full Text PDFIEEE Trans Radiat Plasma Med Sci
January 2018
Including time-of-flight information in positron emission tomography (PET) reconstruction increases the signal-to-noise ratio if the timing information is sufficiently accurate. We estimate timing information by analyzing sampled waveforms, where the sampling frequency and number of samples acquired affect the accuracy of timing estimation. An efficient data-acquisition system acquires the minimum number of samples that contains the most timing information for a desired resolution.
View Article and Find Full Text PDFPurpose: We present a novel gamma-ray-detector design based on total internal reflection (TIR) of scintillation photons within a crystal that addresses many limitations of traditional PET detectors. Our approach has appealing features, including submillimeter lateral resolution, DOI positioning from layer thickness, and excellent energy resolution. The design places light sensors on the edges of a stack of scintillator slabs separated by small air gaps and exploits the phenomenon that more than 80% of scintillation light emitted during a gamma-ray event reaches the edges of a thin crystal with polished faces due to TIR.
View Article and Find Full Text PDFMethotrexate (MTX), as a pharmaceutical, is frequently used in tumor chemotherapy and is also a part of the established treatment of a number of autoimmune inflammatory disorders. Radiolabeled MTX has been studied as a tumor‑diagnostic agent in a number of published studies. In the present study, the potential use of technetium‑99m‑labelled MTX (99mTc‑MTX) as a radiotracer was investigated for the identification of inflammatory target sites.
View Article and Find Full Text PDFMolecular probes capable of detecting colorectal cancer (CRC) are needed for early CRC diagnosis. The objective of this study was to characterize c[CTPSPFSHC]OH (TCP-1), a small peptide derived from phage display selection, for targeting human CRC xenografts using technetium-99m ((99m)Tc)-labeled TCP-1 and fluorescent cyanine-7 (Cy7)-labeled form of the peptide (Cy7-TCP-1). (99m)Tc-TCP-1 was generated by modifying TCP-1 with succinimidyl-6-hydrazino-nicotinamide (S-HYNIC) followed by radiolabeling.
View Article and Find Full Text PDFChronic liver disease is a worldwide health problem, and hepatic fibrosis (HF) is one of the hallmarks of the disease. The current reference standard for diagnosing HF is biopsy followed by pathologist examination; however, this is limited by sampling error and carries a risk of complications. Pathology diagnosis of HF is based on textural change in the liver as a lobular collagen network that develops within portal triads.
View Article and Find Full Text PDFUnlabelled: Apoptosis of macrophages and smooth muscle cells is linked to atherosclerotic plaque destabilization. The apoptotic cascade leads to exposure of phosphatidylethanolamine (PE) on the outer leaflet of the cell membrane, thereby making apoptosis detectable using probes targeting PE. The objective of this study was to exploit capabilities of a PE-specific imaging probe, (99m)Tc-duramycin, in localizing atherosclerotic plaque and assessing plaque evolution in apolipoprotein-E knockout (ApoE(-/-)) mice.
View Article and Find Full Text PDFProc SPIE Int Soc Opt Eng
August 2014
We have investigated the light-transport properties of scintillator arrays with long, thin pixels (deep pixels) for use in high-energy gamma-ray imaging. We compared 10×10 pixel arrays of YSO:Ce, LYSO:Ce and BGO (1mm × 1mm × 20 mm pixels) made by Proteus, Inc. with similar 10×10 arrays of LSO:Ce and BGO (1mm × 1mm × 15mm pixels) loaned to us by Saint-Gobain.
View Article and Find Full Text PDF