Publications by authors named "Lars Ake Brodin"

Objective: Minimally invasive aortic valve replacementsurgery (MIAVR) is an alternative surgical technique to conventional aortic valve replacement surgery (AVR) in selected patients. The randomised study Cardiac Function after Minimally Invasive Aortic Valve Implantation (CMILE) showed that right ventricular (RV) longitudinal function was reduced after both MIAVR and AVR, but the reduction was more pronounced following AVR. However, postoperative global RV function was equally impaired in both groups.

View Article and Find Full Text PDF

Objectives: Decreased right ventricular (RV) longitudinal function following coronary artery bypass grafting (CABG), as assessed by tricuspid annular systolic excursion (TAPSE) and RV peak systolic velocity (RVS') is a known condition. We aimed to explore the feasibility of the right ventricular index of myocardial performance (RIMP) in the assessment of RV function after CABG at rest and during peak dobutamine stress echocardiography (DSE).

Methods: Forty-two patients indicated for CABG were included in this study.

View Article and Find Full Text PDF

Objectives: To estimate the prevalence of self-rated musculoskeletal pain and pain limiting work ability in Swedish Armed Forces (SAF) marines, and to study factors potentially associated with pain limiting work ability for the most prevalent pain regions reported.

Design: Population-based, cross-sectional survey.

Participants: There were 272 SAF marines from the main marine battalion in Sweden included in the study.

View Article and Find Full Text PDF

This work describes the fracturing mechanism of air-filled microbubbles (MBs) encapsulated by a cross-linked poly(vinyl alcohol) (PVA) shell. The radial oscillation and fracturing events following the ultrasound exposure were visualized with an ultrahigh-speed camera, and backscattered timedomain signals were acquired with the acoustic setup specific for harmonic detection. No evidence of gas emerging from defects in the shell with the arrival of the first insonation burst was found.

View Article and Find Full Text PDF

Ultrasound speckle tracking for carotid strain assessment has in the past decade gained interest in studies of arterial stiffness and cardiovascular diseases. The aim of this study was to validate and directly contrast carotid strain assessment by speckle tracking applied on clinical and high-frequency ultrasound images in vitro. Four polyvinyl alcohol phantoms mimicking the carotid artery were constructed with different mechanical properties and connected to a pump generating carotid flow profiles.

View Article and Find Full Text PDF

Combinations of microbubbles (MBs) and superparamagnetic iron oxide nanoparticles (SPIONs) are used to fabricate dual contrast agents for ultrasound and MRI. This study examines the viscoelastic and oscillation characteristics of two MB types that are manufactured with SPIONs and either anchored chemically on the surface (MBs-chem) or physically embedded (MBs-phys) into a polymer shell. A linearized Church model was employed to simultaneously fit attenuation coefficients and phase velocity spectra that were acquired experimentally.

View Article and Find Full Text PDF

Background: A novel polymer-shelled contrast agent (CA) with multimodal and target-specific potential was developed recently. To determine its ultrasonic diagnostic features, we evaluated the endocardial border delineation as visualized in a porcine model and the concomitant effect on physiological variables.

Methods: Three doses of the novel polymer-shelled CA (1.

View Article and Find Full Text PDF

Objective: Tissue Doppler imaging (TDI) is a promising echocardiographic modality allowing quantification of myocardial performance. However, the prognostic potential of TDI in patients with acute myocardial infarction (AMI) is not yet investigated. We sought to explore the ability of TDI in identifying patients at risk for new cardiovascular events after AMI.

View Article and Find Full Text PDF

Aims: Myocardial performance index (MPI) is a measure of combined systolic and diastolic myocardial function. In patients with coronary artery disease (CAD) an increase in MPI is consistent with myocardial dysfunction. The objectives of this study were to characterize the changes in MPI after coronary artery bypass graft (CABG) at rest and at peak dobutamine stress echocardiography (DSE).

View Article and Find Full Text PDF

Background: A multimodal polymer-shelled contrast agent (CA) with target specific potential was recently developed and tested for its acoustic properties in a single element transducer setup. Since the developed polymeric CA has different chemical composition than the commercially available CAs, there is an interest to study its acoustic response when using clinical ultrasound systems. The aim of this study was therefore to investigate the acoustic response by studying the visualization capability and shadowing effect of three polymer-shelled CAs when using optimized sequences for contrast imaging.

View Article and Find Full Text PDF

Objectives: Myocardial function can be evaluated using color-coded tissue velocity imaging (TVI) to analyze the longitudinal myocardial velocity profile, and by expressing the motion of the atrioventricular plane during a cardiac cycle as coordinated events in the cardiac state diagram (CSD). The objective of this study was to establish gestational age specific reference values for fetal TVI measurements and to introduce the CSD as a potential aid in fetal myocardial evaluation.

Methods: TVI recordings from 125 healthy fetuses, at 18 to 42 weeks of gestation, were performed with the transducer perpendicular to the apex to provide a four-chamber view.

View Article and Find Full Text PDF

The aim of this study was to investigate myocardial wall motion using echocardiography and color-coded tissue velocity imaging and to generate a cardiac state diagram for evaluation of the duration of the pre- and post-ejection phases in asphyxiated fetal lambs. Six near-term lambs were partly exteriorized and brought to cardiac arrest through asphyxia. Echocardiography measurements were recorded simultaneously with arterial blood sampling for lactate and blood gases.

View Article and Find Full Text PDF

Background: Tissue Velocity Imaging (TVI) is an ultrasound based technique used for quantitative analysis of the cardiac function and has earlier been evaluated according to myocardial velocities. Recent years several studies have reported applying TVI in the analysis of skeletal muscles. Skeletal tissue velocities can be very low.

View Article and Find Full Text PDF

Left ventricular (LV) dyssynchrony is a known cause of mortality in patients with heart failure and may possibly play a similar role in patients with chronic kidney disease (CKD) in whom sudden death is one of the most common and as yet not fully explained cause of death. LV synchronicity and its relationship with increased volume load and various biomarkers was analyzed in 145 patients including 53 patients with CKD stages 3 and 4 and in 92 CKD stage 5 patients undergoing hemodialysis (HD) or peritoneal dialysis (PD) using color tissue Doppler imaging and tissue synchronization imaging. The HD patients were evaluated both before and after a single HD session.

View Article and Find Full Text PDF

The hemodialysis (HD) procedure induces an inflammatory response potentially contributing to cardiovascular disease. Here we investigated the acute impact of HD on circulating biomarkers. Circulating biomarkers (small solutes, middle molecular-sized peptides, and proteins) related to inflammation, oxidative stress, and vascular calcification (VC) were measured before and after a single session of HD in 45 clinically stable patients.

View Article and Find Full Text PDF

Background: Present data regarding how the fetal heart works and develops throughout gestation is limited. However, the possibility to analyze the myocardial velocity profile provides new possibilities to gain further knowledge in this area. Thus, the objective of this study was to evaluate human fetal myocardial characteristics and deformation properties using color-coded tissue velocity imaging (TVI).

View Article and Find Full Text PDF

Background: The ratio of the early transmitral flow velocity to the early diastolic tissue velocity (E/Em) has been suggested as a reliable estimate of left ventricular diastolic pressures (LVDP). However, the evidence regarding the ability of E/Em to detect LVDP changes is relatively equivocal. Our aim was to evaluate the validity of the ratio following acute load reduction.

View Article and Find Full Text PDF

Background: Role of biomarkers in ST-segment elevation myocardial infarction (STEMI) is paramount, as they aid in diagnosis and gauge prognosis of the disease. In this project, we sought to study the short-term outcome and clinical associates of N-terminal pro-brain natriuretic peptide (NT-proBNP) in the setting of STEMI at a tertiary center in India.

Methods: In all, 173 STEMI patients (mean age: 57 ± 12 years, 38 women) had their NT-proBNP assayed in addition to troponins and high-sensitive C-reactive protein.

View Article and Find Full Text PDF

Ultrasound-based estimation of arterial wall elasticity is commonly used to assess arterial stiffness. However, previous elastography studies have mostly addressed radial strain measurements, and the longitudinal strain has been more or less ignored. This study shows the feasibility of a speckle-tracking-based algorithm for simultaneous estimation of radial and longitudinal strain in the carotid artery in silico.

View Article and Find Full Text PDF

Elderly female hypertensives with arterial stiffening constitute a majority of patients with heart failure with preserved ejection fraction (HFpEF), a condition characterized by inability to increase cardiac stroke volume (SV) with physical exercise. As SV is determined by the interaction between the left ventricle (LV) and its load, we wished to study the role of arterial hemodynamics for exertional SV reserve in patients at high risk of HFpEF. Twenty-one elderly (67 ± 9 yr) female hypertensive patients were studied at rest and during supine bicycle stress using echocardiography including pulsed-wave Doppler to record flow in the LV outflow tract and arterial tonometry for central arterial pressure waveforms.

View Article and Find Full Text PDF

Tissue velocity imaging (TVI) is a Doppler based ultrasound technique that can be used to study regional deformation in skeletal muscle tissue. The aim of this study was to develop a biomechanical model to describe the TVI strain's dependency on the pennation angle. We demonstrate its impact as the subsequent strain measurement error using dynamic elbow contractions from the medial and the lateral part of biceps brachii at two different loadings; 5% and 25% of maximum voluntary contraction (MVC).

View Article and Find Full Text PDF

Aims: The objective of this study was to test the accuracy and diagnostic interchangeability of tissue Doppler-based displacement, velocity, strain, and strain rate measurements in commercially used ultrasound (US) systems.

Methods And Results: Using an in-house made phantom, four different US scanner models were evaluated. Two different scanners of the same model were tested, and one scanner acquisition was tested twice with two generations of the same workstation giving six test results in total.

View Article and Find Full Text PDF

M-Mode echocardiography, 2-D grey scale imaging and standard Doppler that constitute conventional echocardiography has been used for over many decades now. Although these modalities form the backbone in routine clinical echocardiography, its inability to objectively quantify left ventricular function at regional and global levels as well as its loading and heart rate dependency make conventional echocardiography an incomplete tool in clinical situations. Tissue Doppler imaging (which includes myocardial velocity, displacement and strain) has been successfully used in a variety of clinical situations, from investigations of diastolic function to implantation of bi-ventricular pacing for cardiac resynchronization therapy and even in preclinical diagnosis of genetic diseases such as hypertrophic cardiomyopathy.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate mortality and acute myocardial infarction (AMI) incidence among commercial and military flying personnel in Sweden.

Methods: Flying personnel, employed at the Swedish part of Scandinavian Airlines and the Swedish Armed Forces at some point between 1957-1994, were included. The cohort was followed regarding mortality and AMI incidence using national registers of hospital discharges and deaths.

View Article and Find Full Text PDF

The aim here was to employ color tissue velocity imaging (TVI), to test the hypothesis that highly trained endurance athletes exhibit enhanced systolic function of the left ventricular (LV) myocardium both at rest and during combined arm-and-leg exercise in comparison with untrained subjects. For each of the ten elite male (EG) and ten matched control participants (CG), LV dimensions and systolic function were assessed at rest using echocardiography. Subsequently, these subjects exercised continuously on a combined arm-and-leg cycle ergometer for 3 min each at 50, 60, 70, 80, 90 and 100% of VO(2max).

View Article and Find Full Text PDF