: This study focuses on the ability of vaping technology to deliver beclomethasone dipropionate compared to nebulization. : An in vitro comparison of aerosol properties in terms of respirable dose with the Glass Twin Impinger and the mass median aerodynamic diameter using the Next Generation Impactor was performed. The respirable dose delivered in a vaping drug delivery system (VDDS) puff as a function of concentration was quantified by high-pressure liquid chromatography coupled with an ultraviolet detector.
View Article and Find Full Text PDFThe aim of this study was to quantify the number of non-airborne bacteria that can passively penetrate the layers of four mask types (surgical mask, community face mask type 1 (CFM1), biocidal CFM1 and CFM2) and to determine the influence of wearing conditions for the surgical type. A mask wearer simulator consisting of a 3D anatomical replica of the upper airway connected to a breathing pump was used. Wearing time, filtration quality of the mask, fit (loose vs.
View Article and Find Full Text PDFPurpose: The aim of this study is to evaluate and compare the performance, for the administration of fluticasone propionate with a pressurized metered-dose inhaler (pMDI), of two low-tech paperboard spacers versus two commercially available valved holding chambers (VHC).
Methods: According to the Canadian standard CAN/CSA-Z264.1-02, total emitted dose (TED) and aerodynamic size distribution were measured for the pMDI in combination with 4 different spacers: a homemade paper cup spacer, the DispozABLE® paperboard spacer, the AeroChamber Plus® plastic VHC, and the Vortex® aluminium VHC.
Background: Electronic cigarettes (EC) have gained popularity, especially among young people, with the introduction of fourth-generation devices based on e-liquids containing nicotine salts that promise a smoother vaping experience than freebase nicotine. However, the toxicological effects of nicotine salts are still largely unknown, and the chemical diversity of e-liquids limits the comparison between different studies to determine the contribution of each compound to the cytotoxicity of EC aerosols. Therefore, the aim of this study was to evaluate the toxicological profile of controlled composition e-liquid aerosols to accurately determine the effects of each ingredient based on exposure at the air-liquid interface.
View Article and Find Full Text PDFTo investigate potential correlations between human exposure to inhaled particles and pathological effects, the biological monitoring of nanoparticles in broncho-alveolar lavages (BAL) from patients has been proposed. To better understand the underlying mechanisms of toxicity, we propose to couple this biomonitoring of nanoparticles to their toxicity assessment. However, BAL obtained from regular clinical practice are conditioned with sodium hypochlorite solution (in a 50% v/v ratio), which is toxic to cells.
View Article and Find Full Text PDFThis work aims to investigate bronchodilator delivery with the use of different vaping drug delivery systems (VDDS) by determining the dose equivalence delivered in relation to different references: a clinical jet nebulizer, a pMDI (pressurized metered dose inhaler) and a DPI (dry powder inhaler). Three different bronchodilators were used (terbutaline, salbutamol hemisulfate, ipratropium bromide). The e-liquids contained the active pharmaceutical ingredient (API) in powder form.
View Article and Find Full Text PDFSuccessful aerosol therapy in mechanically ventilated patients depends on multiple factors. Among these, position of nebulizer in ventilator circuit and humidification of inhaled gases can strongly influence the amount of drug deposited in airways. Indeed, the main objective was to preclinically evaluate impact of gas humidification and nebulizer position during invasive mechanical ventilation on whole lung and regional aerosol deposition and losses.
View Article and Find Full Text PDFBackground: We assessed/compared the evolution of tobacco and e-cigarette experimentation and use among French adolescents of the Loire department aged 15-16 years.
Methods: A descriptive, cross-sectional/observational study conducted in 2018-2020 among 7,950 Year 11 pupils attending 27 public secondary schools of the Loire department, France.
Results: From 2018 to 2020, 66.
Introduction: We describe the vaping and smoking habits of French adolescents aged 15-16 years in the Loire department with a view to assess the impact of e-cigarette experimentation and use on their smoking behavior.
Methods: This quantitative, cross-sectional, single-center and observational study conducted from January to July 2019 targeted 6622 students aged 15-16 years attending public high school in the Loire department, France.
Results: A total of 4937 (74.
This study aims to evaluate the impact of the nasal delivery technique and nebulizing technologies (using different frequencies of oscillating airflow) for acoustic aerosol targeting of maxillary sinuses. Sodium fluoride (chemical used as a marker), tobramycin (drug used as a marker) and Tc-DTPA (radiolabel aerosol) were used to assess the intrasinus aerosol deposition on a nasal cast. Two commercial medical devices (PARI SINUS nebulizer and NL11SN ATOMISOR nebulizer) and various nasal delivery techniques (one or two nostrils connected to the aerosol inlet, the patient with the soft palate closed or open during the acoustic administration of the drug, the presence or not of flow resistance in the nostril opposite to the one allowing the aerosol to be administered) were evaluated.
View Article and Find Full Text PDFFace masks are often recommended in community settings to prevent the airborne transmission of respiratory viruses or bacteria. Our first objective was to develop an experimental bench to assess the viral filtration efficiency (VFE) of a mask with a methodology similar to the normative measurement of bacterial filtration efficiency (BFE) used to determine the filtration performance of medical masks. Then, using three categories of masks of increasing filtration quality (two types of community masks and one type of medical mask), filtration performances measured ranged from 61.
View Article and Find Full Text PDFIntroduction : Longitudinal studies make it possible to study the evolution of a class of individuals over time. However, they are rarely used in France to observe the same population of young adolescents according to their grade level over the course of several years.Purpose of research : Based on the longitudinal monitoring of repeated annual cross-sectional studies on young adolescents (from 15 to 18 years old) conducted at the Honoré d’Urfé public high school (Saint-Étienne, Loire, France) involving 336 10th grade pupils in 2018, 360 11th grade pupils in 2019 and 273 12th grade pupils in 2020, we observed and studied students’ smoking and vaping behavior over a period of three years.
View Article and Find Full Text PDFThe potential cardiovascular effects of e-cigarettes remain largely unidentified and poorly understood. E-liquids contain numerous chemical compounds and can induce exposure to potentially toxic ingredients (e.g.
View Article and Find Full Text PDFIn the field of biomonitoring, exhaled breath condensate (EBC) is described as a potentially useful matrix for assessing inhalation exposure biomarkers in a non-invasive way. However, it is still unclear to what extent EBC is representative of the deep lung. To address this knowledge gap, EBC, bronchial washes (BWs), and bronchoalveolar lavages (BALs) were collected from 82 patients suffering from interstitial lung diseases (ILDs).
View Article and Find Full Text PDFPurpose: Several technical features influencing bronchodilator delivery were evaluated using different vaping drug delivery systems (VDDS).
Methods: Terbutaline in powder form, combined with 1, 3- propanediol used as e-liquid was tested at different concentrations (1 and 2.5 mg/mL), power levels (15 W and 30 W), and set applied resistances (0.
Can medical face masks be replaced by reusable community face masks with similar performance? The influence of the number of wash cycles, the wash temperature and the use of detergent was evaluated on the performance of one medical face masks (MFM) and ten community face masks (CFM). The performance of the new and washed masks was characterized from the bacterial filtration efficiency (BFE) and the differential pressure (DP). The tests on the new masks showed that the MFM had always better BFE than CFMs.
View Article and Find Full Text PDFGiven that nicotine salts are a growing market, methods are needed to characterize nicotine forms in e-cigarette vaping products. By lowering the free-base nicotine fraction (α) in favor of protonated forms, the addition of organic acids to the e-liquid mix greatly modulates nicotine pharmacokinetics and improves vapers' craving. This research investigated (1) the performance of pH measurement, liquid-liquid extraction (LLE), and acid/nicotine molar ratio calculation methods for α estimation in 6 nicotine benzoate and nicotine salicylate e-liquids and (2) nicotine protonation in the aerosol post vaporization.
View Article and Find Full Text PDFInt J Environ Res Public Health
March 2022
The increase in legionellosis incidence in the general population in recent years calls for a better characterization of the sources of infection, such as showering. Water-efficient shower systems that use water-atomizing technology have been shown to emit slightly more inhalable particles in the range of bacterial sizes than the traditional systems; however, the actual rate of bacterial emission remains poorly documented. The aim of this study was to assess the aerosolisation rate of the opportunistic water pathogen during showering with one shower system representative of each technology.
View Article and Find Full Text PDFAs a result of the current COVID-19 pandemic, the use of facemasks has become commonplace. The performance of medical facemasks is assessed using Bacterial Filtration Efficiency (BFE) tests. However, as BFE tests, require specific expertise and equipment and are time-consuming, the performance of non-medical facemasks is assessed with non-biological Particle Filtration Efficiency (PFE) tests which are comparatively easier to implement.
View Article and Find Full Text PDFThe need for personal protective equipment increased exponentially in response to the Covid-19 pandemic. To cope with the mask shortage during springtime 2020, a French consortium was created to find ways to reuse medical and respiratory masks in healthcare departments. The consortium addressed the complex context of the balance between cleaning medical masks in a way that maintains their safety and functionality for reuse, with the environmental advantage to manage medical disposable waste despite the current mask designation as single-use by the regulatory frameworks.
View Article and Find Full Text PDFBased on the current knowledge of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) transmission, wearing a mask has been recommended during the COVID-19 pandemic. Bacterial filtration efficiency (BFE) measurements enable designing and regulating medical masks to prevent bioaerosol dissemination; however, despite the simplicity of these measurements, several scientific questions remain unanswered regarding BFE tests. Here, we investigated (1) the impact of substituting 100-mm Petri dishes with 90-mm disposable Petri dishes, (2) the impact of colony-counting methods on the bioaerosol aerodynamic size, and (3) the impact of colony-counting methods on the total viable particle counts.
View Article and Find Full Text PDFThe reliable characterization of particle size distribution and nicotine delivery emitted by electronic cigarettes (ECs) is a critical issue in their design. Indeed, a better understanding of how nicotine is delivered as an aerosol with an appropriate aerodynamic size is a necessary step toward obtaining a well-designed nicotine transfer from the respiratory tract to the bloodstream to better satisfy craving and improve smoking cessation rates. To study these two factors, recent models of EC devices and a dedicated vaping machine were used to generate aerosols under various experimental conditions, including varying the EC power level using two different types of atomizers.
View Article and Find Full Text PDFDue to their unique properties TiO nanoparticles are widely used. The adverse effects they may elicit are usually studied in relation to their physicochemical features. However, a factor is often neglected: the influence of the protein corona formed around nanoparticles upon contact with biological media.
View Article and Find Full Text PDF