A selective, specific, precise, linear, accurate and robust analytical method was developed and validated for the assay of vancomycin HCl in vancomycin hydrochloride injection. Comparative UV spectrophotometric and reverse-phase HPLC were used to develop the quantitative determination. Acetonitrile and pH 2.