Publications by authors named "Langohr G"

Introduction: Stress shielding remains a concern following total shoulder arthroplasty using press-fit short humeral stems. While the effect of alterations in implant geometry, positioning, and sizing on stress shielding have been investigated, the effects of coverage of the cortical boundary of the resection plane have not yet been fully explored. The purpose of this study was to quantify the effect of improved cortical coverage using elliptical vs.

View Article and Find Full Text PDF

Objective assessments of shoulder motion are paramount for effective rehabilitation and evaluation of surgical outcomes. Inertial Measurement Units (IMU) have demonstrated promise in providing unbiased movement data. This study is dedicated to evaluating the concurrent construct validity and accuracy of a wearable IMU-based sensor system, called 'Motion Shirt', for the assessment of humero-thoracic motion arcs in patients awaiting shoulder replacement surgery.

View Article and Find Full Text PDF

The bicipital groove is an important anatomical feature of the proximal humerus that needs to be identified during surgical planning for procedures such as shoulder arthroplasty and proximal humeral fracture reconstruction. Current algorithms for automatic identification prove ineffective in arthritic humeri due to the presence of osteophytes, reducing their usefulness for total shoulder arthroplasty. Our methodology involves the use of a Random Forest Classifier (RFC) to automatically detect the bicipital groove on segmented computed tomography scans of humeri.

View Article and Find Full Text PDF

Background: Shoulder arthroplasty humeral stem design has evolved to include various shapes, coatings, lengths, sizes, and fixation methods. While necessary to accommodate patient anatomy characteristics, this creates a surgical paradox of choice. The relationship between the surgeon's selection of short-stem implant size and construct stiffness, resistance to subsidence and micromotion has not been assessed.

View Article and Find Full Text PDF

Background: Stemless anatomic humeral components are commonly used and are an accepted alternative to traditional stemmed implants in patients with good bone quality. Presently, little literature exists on the design and implantation parameters that influence primary time-zero fixation of stemless reverse humeral implants. Accordingly, this finite element analysis study assessed the surgical implantation variable of neck-shaft angle, and its effect on the primary time-zero fixation of reversed stemless humeral implants.

View Article and Find Full Text PDF

Background: The use of uncemented humeral stems in total shoulder arthroplasty (TSA) is known to be associated with stress shielding. This may be decreased with smaller stems that are well-aligned and do not fill the intramedullary canal; however, the effect of humeral head positioning and incomplete head backside contact has not yet been investigated. The purpose of this study was to quantify the effect of changes in humeral head position and incomplete head backside contact on bone stresses and expected bone response following reconstruction.

View Article and Find Full Text PDF

Background: Total shoulder arthroplasty (TSA) implants have evolved to include more anatomically shaped components that better replicate the native state. The geometry of the humeral head is nonspherical, with the frontal diameter of the base of the head being up to 6% larger than the sagittal diameter. Despite this, most TSA humeral head implants are spherical, meaning that the diameter must be oversized to achieve complete coverage, resulting in articular overhang, or portions of the resection plane will remain uncovered.

View Article and Find Full Text PDF

Background: The purpose of this biomechanical simulator study was primarily to compare latissimus dorsi to lower trapezius tendon transfers for active external rotation and the pectoralis major transfer for internal rotation after reverse shoulder arthroplasty. Secondarily, the role of humeral component lateralization on transfer function was assessed.

Methods: Eight rotator cuff deficient cadavers underwent reverse shoulder arthroplasty with an adjustable lateralization humeral component.

View Article and Find Full Text PDF

The use of uncemented humeral stems in total shoulder arthroplasty (TSA) is associated with stress shielding. Shorter length stems have shown to decrease stress shielding; however, the effect of stem varus-valgus alignment is currently not known. The purpose of this study was to quantify the effect of short stem distal humeral endosteal contact due to varus-valgus angulation on bone stresses after TSA.

View Article and Find Full Text PDF

Background: Scapular spine insufficiency fractures following reverse shoulder arthroplasty are poorly understood. There exists limited literature regarding the role of reverse shoulder arthroplasty lateralization on scapular spine strains and fractures. The purpose of this cadaveric biomechanical simulator study was to evaluate the role of glenoid lateralization on scapular spine strain.

View Article and Find Full Text PDF

Background: Stem size is an important element for successful time zero primary fixation of a press-fit humeral stem in shoulder arthroplasty. Little basic science research, however, has been conducted on the effects of implant thickness and canal fill on load transfer, contact, and stress shielding. The purpose of this finite element study was to determine the effects of varying stem thickness on bone contact, bone stresses, and bone resorption owing to stress shielding.

View Article and Find Full Text PDF

Background: The humeral head osteotomy during shoulder arthroplasty influences humeral component height, version and possibly neck-shaft angle. These parameters all potentially influence outcomes of anatomic and reverse shoulder replacement to a variable degree. Patient-specific guides and navigation have been studied and utilized clinically for glenoid component placement.

View Article and Find Full Text PDF

Background: Acromial fractures are a substantial complication following reverse shoulder arthroplasty, reported to affect up to 7% of patients. Previous studies have shown that implant placement affects acromial stress during elevation of the arm in the scaption plane. The purpose of this study was to investigate the results of arm loading and variation in plane of elevation on acromial stresses.

View Article and Find Full Text PDF

Background: Hemiarthroplasties cause damage to the cartilage that they articulate against, which is a major limitation to their use. This study investigated the use of lower-stiffness materials to determine whether they improve hemiarthroplasty contact mechanics and thus reduce the risk of cartilage damage.

Methods: Eleven fresh-frozen cadaveric upper extremities were disarticulated and fixed in a custom-built jig that applied a static load of 50 N to the radiocapitellar joint.

View Article and Find Full Text PDF

Background: Bone quality influences humeral implant selection for shoulder arthroplasty. However, little is known about how well bone near the humeral resection represents more distal cancellous bone. This investigation aimed to quantify the correlations between the apparent density of sites near the humeral head resection plane and cancellous sites throughout the metaphysis.

View Article and Find Full Text PDF

Stress shielding of the proximal humerus following total shoulder arthroplasty (TSA) can promote unfavorable bone remodeling, especially for osteoporotic patients. The objective of this finite element (FE) study was to determine if a hollow, rather than solid, titanium stem can mitigate this effect for healthy, osteopenic, and osteoporotic bone. Using a population-based model of the humerus, representative average healthy, osteopenic, and osteoporotic humerus FE models were created.

View Article and Find Full Text PDF

Background: The optimal insertion location of a latissimus dorsi tendon transfer to restore external rotation after reverse shoulder arthroplasty (RSA) is not well established. The aim of this biomechanical study was to determine the effect of tendon transfer location on external rotation torque, in conjunction with varying RSA humeral component lateralization. We hypothesized that proximal tendon transfers, along with increasing humeral lateralization, would maximize external rotation torque.

View Article and Find Full Text PDF

Purpose: To compare changes in wrist kinematics after scaphoidectomy and four-corner fusion (4CF), and proximal row carpectomy (PRC).

Methods: Six cadaveric specimens underwent flexion-extension, radial-ulnar deviation and circumduction in an active motion wrist simulator. Native state, "anatomic 4CF", "radial 4CF", and PRC were compared.

View Article and Find Full Text PDF

Purpose: All active motion wrist joint simulators have been designed to simulate physiologic wrist motion; however, a main difference among them is the orientation of the forearm (horizontal or vertical with respect to gravity). Moreover, the effect of forearm orientation on experimental results has yet to be quantified, but it may be an important variable. Thus, the purpose of this study was to determine the effect of forearm orientation on wrist kinematics and contact mechanics.

View Article and Find Full Text PDF

Three-dimensional motion analysis of the hand and wrist is common in in-vitro and in-vivo biomechanical research. However, all studies rely on post testing analysis, where anatomical joint coordinate systems (JCS) are created to generate clinically relevant data to describe wrist motion. The purpose of this study was to present a comparison of four JCS that have been previously described in literature.

View Article and Find Full Text PDF

Background: A resorbable subacromial balloon has been developed to address humeral head migration following posterosuperior rotator cuff tears. The purpose of this experimental assessment was to quantify the effect of balloon augmentation on humeral head position.

Methods: Eight cadaveric shoulders were subjected to 0°, 30°, 60° and 90° of abduction via a shoulder simulator.

View Article and Find Full Text PDF

Background: This in vivo kinematic study was developed to ascertain (1) elbow posture and motion during daily activities and (2) to compare motions of the dominant and nondominant elbows.

Methods: Forty-six subjects wore a custom instrumented shirt to continuously measure elbow posture and motion for the waking hours of 1 day. The 3D orientations of each of the forearm and humerus sensors enabled calculation of elbow flexion-extension and pronation-supination angles.

View Article and Find Full Text PDF

Background: Reverse shoulder arthroplasty (RSA) humeral implant parameters have been previously studied with respect to range of motion, deltoid function, and stability. However, limited literature exists on the influence of humeral design features on scapular spine strain. The purpose of this cadaveric biomechanical simulator study was to evaluate the role of humeral component lateralization and neck-shaft angle (NSA) on scapular spine strain.

View Article and Find Full Text PDF

Biomechanics research often requires cadaveric whole bones to be stored in a freezer and then thawed prior to use; however, the literature shows a variety of practices for thawing. Consequently, this is the first study to report the mechanical properties of fully frozen versus fully thawed whole bone as 'proof of principle'. Two groups of 10 porcine ribs each were statistically equivalent at baseline in length, cross-sectional area, and bone mineral density.

View Article and Find Full Text PDF

Hemiarthroplasty is often preferred to total arthroplasty as it preserves native tissue; however, accelerated wear of the opposing cartilage is problematic. This is thought to be caused by the stiffness mismatch between the implant and cartilage-bone construct. Reducing the stiffness of the implant by changing the material has been hypothesized as a potential solution.

View Article and Find Full Text PDF