Continuous monitoring of acute inflammation can become a very important next step for guiding therapeutic interventions in severely ill patients. This Perspective discusses the current medical need for patients with acute inflammatory diseases and the potential of continuous biosensing technologies. First, we discuss biomarkers that could help to monitor the state of a patient with acute systemic inflammation based on theoretical studies and empirical data.
View Article and Find Full Text PDFUnderstanding the intricate functions of membrane proteins is pivotal in cell biology and drug discovery. The composition of the cell membrane is highly complex, with different types of membrane proteins and lipid species. Hence, studying cellular membranes in a complexity-reduced context is important to enhance our understanding of the roles of these different elements.
View Article and Find Full Text PDFPartially fluorinated nanoparticles (FNPs) have been proposed as a promising alternative for stabilising aqueous droplets in fluorinated oils. The exceptional energetic stability of FNPs at the droplet interface holds the potential for minimising leakage, enhancing stability, and promoting improved cell adhesion. However, their lower diffusion coefficient compared to surfactants presents challenges in achieving rapid droplet stabilisation, which is important in microfluidics applications.
View Article and Find Full Text PDFSelf-powered microfluidics presents a revolutionary approach to address the challenges of healthcare in decentralized and point-of-care settings where limited access to resources and infrastructure prevails or rapid clinical decision-making is critical. These microfluidic systems exploit physical and chemical phenomena, such as capillary forces and surface tension, to manipulate tiny volumes of fluids without the need for external power sources, making them cost-effective and highly portable. Recent technological advancements have demonstrated the ability to preprogram complex multistep liquid operations within the microfluidic circuit of these standalone systems, which enabled the integration of sensitive detection and readout principles.
View Article and Find Full Text PDFDilution is a standard fluid operation widely employed in the sample preparation process of many bio(chemical) assays. It serves multiple essential functions such as sample mixing with certain reagents at specific dilution ratios, reducing sample matrix effects, bringing target analytes within the linear assay detection range, among many others. Traditionally, sample processing is performed in laboratory settings through manual or automated pipetting.
View Article and Find Full Text PDFIn this study, we explore the full-spectrum capabilities of fiber-optic surface plasmon resonance (FO-SPR) for analyzing heterogeneous samples with increased comprehensiveness. Our approach involves refining a literature-derived FO-SPR model to more precisely reflect experimental data obtained using a back-reflecting sensor configuration. Key enhancements in our model include adjustments to the thickness and permittivity of the gold SPR-active layer on the FO-SPR sensor as well as improvements to the angular distribution of light within the system.
View Article and Find Full Text PDFThe day-old male chick culling remains a welfare issue in the poultry industry. Several governments have prohibited this practice, pushing hatcheries to seek alternatives. Although different solutions exist for solving this problem, sex determination during the embryo's incubation ( sexing) is considered the most suitable one among the consumers and industry.
View Article and Find Full Text PDFVolatile organic compounds (VOCs) carry crucial information about chicken egg fertility. Assessing the fertility before incubation holds immense potential for poultry industry efficiency. Our study used headspace sorptive extraction-gas chromatography-mass spectrometry to analyze egg VOCs before and during the initial 12 incubation days.
View Article and Find Full Text PDFBackground: Laboratory diagnosis of immune-mediated thrombotic thrombocytopenic purpura (iTTP) remains challenging when ADAMTS-13 activity ranges between 10% and 20%. To prevent misdiagnosis, open ADAMTS-13 conformation gained clinical attention as a novel biomarker, especially to diagnose acute iTTP in patients with diagnostic undecisive ADAMTS-13 activity. Plasma ADAMTS-13 conformation analysis corrects for ADAMTS-13 antigen, with both parameters being characterized in enzyme-linked immunosorbent assay (ELISA)-based reference assays requiring expert technicians.
View Article and Find Full Text PDFOver the past decade, advanced analytical techniques have been utilized to examine volatile organic compounds (VOCs) in eggs. These VOCs offer valuable insights into factors such as freshness, fertility, the presence of cracks, embryo sex, and breed. In our study, we assessed three mass spectrometry-based systems (headspace sorptive extraction gas chromatography-mass spectrometry; HSSE-GC-MS, proton transfer reaction time-of-flight-mass spectrometry; PTR-TOF-MS; and selected ion flow tube mass spectrometry; SIFT-MS) to analyze and identify VOCs present in intact hatching eggs from three distinct breeds (Dekalb white layer, Shaver brown layer, and Ross 308 broiler).
View Article and Find Full Text PDFEngineered lysins are considered as highly promising alternatives for antibiotics. Our previous screening study using VersaTile technology identified 1D10 as a possible lead compound with activity against strains under elevated human serum concentrations. In this manuscript, we reveal an unexpected mode of action and exceptional thermoresistance for lysin 1D10.
View Article and Find Full Text PDFIn the quest to produce artificial cells, one key challenge that remains to be solved is the recreation of a complex cellular membrane. Among the existing models, giant unilamellar vesicles (GUVs) are particularly interesting due to their intrinsic compartmentalisation ability and their resemblance in size and shape to eukaryotic cells. Many techniques have been developed to produce GUVs all having inherent advantages and disadvantages.
View Article and Find Full Text PDFDNA-based enzymes, or DNAzymes, are single-stranded DNA sequences with the ability to catalyze various chemical reactions, including the cleavage of the bond between two RNA nucleotides. Lately, an increasing interest has been observed in these RNA-cleaving DNAzymes in the biosensing and therapeutic fields for signal generation and the modulation of gene expression, respectively. Additionally, multiple efforts have been made to study the effects of the reaction environment and the sequence of the catalytic core on the conversion of the substrate into product.
View Article and Find Full Text PDFBackground: Thrombotic thrombocytopenic purpura (TTP) is characterized by severe ADAMTS-13 activity deficiency (<10%). Diagnostic testing is challenging because of unavailability, high cost, and expert technician requirement of ADAMTS-13 enzyme assays. Cost-effective, automated fiber-optic surface plasmon resonance (FO-SPR) platforms show potential for developing diagnostic tests.
View Article and Find Full Text PDFSelected ion flow tube-mass spectrometry (SIFT-MS) is an analytical technique for volatile detection and quantification. SIFT-MS can be applied in a "white box" approach, measuring concentrations of target compounds, or as a "black box" fingerprinting technique, scanning all product ions during a full scan. Combining SIFT-MS full scan data acquired from multibatches or large-scale experiments remains problematic due to signal fluctuation over time.
View Article and Find Full Text PDFNumerous researchers and institutions have been developing in ovo sexing technologies to improve animal welfare by identifying male embryos in an early embryonic stage and disposing of them before pain perception. This review gives a complete overview of the technological approaches reported in papers and patents by performing a thorough search using Web of Science and Patstat/Espacenet databases for papers and patents, respectively. Based on a total of 49 papers and 115 patent families reported until May 2023 worldwide, 11 technology categories were defined: 6 non-optical and 5 optical techniques.
View Article and Find Full Text PDFMicroneedles are gaining a lot of attention in the context of sampling cutaneous biofluids such as capillary blood. Their minimal invasiveness and user-friendliness make them a prominent substitute for venous puncture or finger-pricking. Although the latter is suitable for self-sampling, the impracticality of manual handling and the difficulty of obtaining enough qualitative sample is driving the search for better solutions.
View Article and Find Full Text PDFExtracellular vesicles (EVs) have attracted great attention as potential biomarkers for cancer diagnostics. Although several technologies have been developed for EV detection, many of them are still not applicable to clinical settings as they rely on complex EV isolation processes, while lacking sensitivity, specificity or standardization. To solve this problem, we have developed a sensitive breast cancer-specific EV detection bioassay directly in blood plasma using a fiber-optic surface plasmon resonance (FO-SPR) biosensor, previously calibrated with recombinant EVs.
View Article and Find Full Text PDFThroughout the past decades, fiber optic surface plasmon resonance (FO-SPR)-based biosensors have proven to be powerful tools for both the characterization of biomolecular interactions and target detection. However, as FO-SPR signals are generally related to the mass that binds to the sensor surface, multistep processes and external reagents are often required to obtain significant signals for low molecular weight targets. This increases the time, cost, and complexity of the respective bioassays and hinders continuous measurements.
View Article and Find Full Text PDFThis paper presents porous polydimethylsiloxane (PDMS) optical phantoms with tunable microstructural and optical properties to mimic porous biological tissues (e.g., fruit) during the design and optimization of novel optical setups.
View Article and Find Full Text PDFIn the continuous combat against diseases, there is the need for tools that enable an improved diagnostic efficiency towards higher information density combined with reduced time-to-result and cost. Here, a novel fully integrated microfluidic platform, the Evalution™, is evaluated as a potential solution to this need. Encoded microparticles combined with channel-based microfluidics allow a fast, sensitive and simultaneous detection of several disease-related biomarkers.
View Article and Find Full Text PDFAdvancements in lab-on-a-chip technologies have revolutionized the single-cell analysis field. However, an accessible platform for in-depth screening and specific retrieval of single cells, which moreover enables studying diverse cell types and performing various downstream analyses, is still lacking. As a solution, FLUIDOT is introduced, a versatile microfluidic platform incorporating customizable microwells, optical tweezers and an interchangeable cell-retrieval system.
View Article and Find Full Text PDFFluorescence in situ hybridization (FISH) is the gold standard for visualizing genomic DNA in fixed cells and tissues, but it is incompatible with live-cell imaging, and its combination with RNA imaging is challenging. Consequently, due to its capacity to bind double-stranded DNA (dsDNA) and design flexibility, the clustered regularly interspaced short palindromic repeats (CRISPR)-CRISPR-associated protein 9 (CRISPR-Cas9) technology has sparked enormous interest over the past decade. In this review, we describe various nucleic acid (NA)- and protein-based (amplified) signal generation methods that achieve imaging of repetitive and single-copy sequences, and even single-nucleotide variants (SNVs), next to highly multiplexed as well as dynamic imaging in live cells.
View Article and Find Full Text PDFThe need for self-referencing is extremely important in the field of biosensing. In this manuscript, we report on the study, design, and validation of a dual-region self-referencing fiber-optic surface plasmon resonance biosensor. One region is intended to measure and monitor the binding events of the biological sample under test, while the other one is designed to be used as a reference channel to compensate for external factors, such as bulk refractive index modifications and temperature oscillations, that can negatively affect the biomolecular interaction measurement.
View Article and Find Full Text PDF