The assessment of skin sensitisation is a key requirement in all regulated sectors, with the European Union's regulation of cosmetic ingredients being most challenging, since it requires quantitative skin sensitisation assessment based on new approach methodologies (NAMs). To address this challenge, an in-depth and harmonised understanding of NAMs is fundamental to inform the assessment. Therefore, we compiled a database of NAMs, and in vivo (human and local lymph node assay) reference data.
View Article and Find Full Text PDFAll cosmetic products placed onto the market must undergo a risk assessment for human health to ensure they are safe for consumers, including an assessment of skin sensitisation risk. Historically, in vivo animal test methods were used to identify and characterise skin sensitisation hazard, however non-animal and other new approach methodologies (NAMs) are now the preferred and mandated choice for use in risk assessment for cosmetic ingredients. The experience gained over the last three decades on how to conduct risk assessments based upon NAMs has allowed us to develop a non-animal, next generation risk assessment (NGRA) framework for the assessment of skin sensitisers.
View Article and Find Full Text PDFCosmetics Europe, the European Trade Association for the cosmetics and personal care industry, is conducting a multi-phase program to develop regulatory accepted, animal-free testing strategies enabling the cosmetics industry to conduct safety assessments. Based on a systematic evaluation of test methods for skin sensitization, five non-animal test methods (DPRA (Direct Peptide Reactivity Assay), KeratinoSens, h-CLAT (human cell line activation test), U-SENS, SENS-IS) were selected for inclusion in a comprehensive database of 128 substances. Existing data were compiled and completed with newly generated data, the latter amounting to one-third of all data.
View Article and Find Full Text PDF: The use of this material under current conditions is supported by existing information. This material was evaluated for genotoxicity, repeated dose toxicity, developmental and reproductive toxicity, local respiratory toxicity, phototoxicity/photoallergenicity, skin sensitization, as well as environmental safety. Data show that this material is not genotoxic nor does it have skin sensitization potential.
View Article and Find Full Text PDFThe use of this material under current conditions is supported by existing information. This material was evaluated for genotoxicity, repeated dose toxicity, developmental and reproductive toxicity, local respiratory toxicity, phototoxicity/photoallergenicity, skin sensitization, as well as environmental safety. Data show that this material is not genotoxic.
View Article and Find Full Text PDFThe use of this material under current conditions is supported by existing information. This material was evaluated for genotoxicity, repeated dose toxicity, developmental and reproductive toxicity, local respiratory toxicity, phototoxicity/photoallergenicity, skin sensitization, as well as environmental safety. Data from the suitable read across analog linalool (CAS # 78-70-6) show that this material is not genotoxic nor does it have skin sensitization potential and also provided a MOE > 100 for the local respiratory endpoint.
View Article and Find Full Text PDFThe use of this material under current conditions is supported by existing information. This material was evaluated for genotoxicity, repeated dose toxicity, developmental and reproductive toxicity, local respiratory toxicity, phototoxicity/photoallergenicity, skin sensitization, as well as environmental safety. Data from the suitable read across analog 2-ethylhexanol (CAS # 104-76-7) show that this material is not genotoxic.
View Article and Find Full Text PDFThe use of this material under current conditions is supported by existing information. This material was evaluated for genotoxicity, repeated dose toxicity, developmental toxicity, reproductive toxicity, local respiratory toxicity, phototoxicity, skin sensitization, as well as environmental safety. Data show that this material is not genotoxic.
View Article and Find Full Text PDFThe use of this material under current use conditions is supported by the existing information. This material was evaluated for genotoxicity, repeated dose toxicity, developmental and reproductive toxicity, local respiratory toxicity, phototoxicity/photoallergenicity, skin sensitization, as well as environmental safety. Data from the suitable read across analog benzyl acetate (CAS # 140-11-4) show that this material is not genotoxic nor does it have skin sensitization potential and also provided a MOE > 100 for the repeated dose, developmental and reproductive, and local respiratory toxicity endpoints.
View Article and Find Full Text PDF