Objective: To compare specimens obtained with the Fischer cone biopsy excisor or loop electrosurgical excision procedure (LEEP) with respect to number of specimens obtained, margin interpretability, adequacy of excision, and ease of use.
Methods: One hundred eligible patients aged 13 years and older were randomly assigned to treatment with the Fischer cone biopsy excisor or LEEP. Eligibility criteria included: (1) cervical intraepithelial neoplasia (CIN) 2 or 3, (2) persistent CIN 1, or (3) cytologic/histologic discrepancy.