Publications by authors named "Lahsen Assoufid"

Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains.

View Article and Find Full Text PDF

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation.

View Article and Find Full Text PDF

Coherent X-ray imaging is an active field at synchrotron sources. The images rely on the available coherent flux over a limited field of view. At many synchrotron beamlines a double-crystal monochromator (DCM) is employed in a standard nondispersive arrangement.

View Article and Find Full Text PDF

Next-generation synchrotron radiation facilities, such as the Advanced Photon Source Upgrade (APS-U), bring significant advancements in scientific research capabilities, necessitating advanced diagnostic tools. Central to these diagnostics are x-ray wavefront sensors, crucial for preserving beam properties, including brightness, coherence, and stability. This paper presents two novel wavefront sensor prototypes developed at the APS using the coded-mask-based technique.

View Article and Find Full Text PDF

We describe the application of an AI-driven system to autonomously align complex x-ray-focusing mirror systems, including mirrors systems with variable focus spot sizes. The system has been developed and studied on a digital twin of nanofocusing X-ray beamlines, built using advanced optical simulation tools calibrated with wavefront sensing data collected at the beamline.We experimentally demonstrated that the system is reliably capable of positioning a focused beam on the sample, both by simulating the variation of a beamline with random perturbations due to typical changes in the light source and optical elements over time, and by conducting similar tests on an actual focusing mirror system.

View Article and Find Full Text PDF

The advent of next-generation synchrotron radiation sources and X-ray free-electron lasers calls for high-quality Bragg-diffraction crystal optics to preserve the X-ray beam coherence and wavefront. This requirement brings new challenges in characterizing crystals in Bragg diffraction in terms of Bragg-plane height errors and wavefront phase distortions. Here, a quantitative methodology to characterize crystal optics using a state-of-the-art at-wavelength wavefront sensing technique and statistical analysis is proposed.

View Article and Find Full Text PDF

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory.

View Article and Find Full Text PDF

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated.

View Article and Find Full Text PDF

Measured diffuse X-ray scattering data for a `smooth' as well as for a `rough' silicon sample were fit to theoretical expressions within the distorted wave Born approximation (DWBA). Data for the power spectral density (PSD) for both samples were also obtained by means of atomic force microscopy and optical interferometry. The Fourier transforms of trial correlation functions were fit to the PSD data and then applied to the DWBA formalism.

View Article and Find Full Text PDF
Article Synopsis
  • Four-beam diffraction (4BD) is only activated by a specific photon energy and angle of incidence, making it useful for precise calibration of X-ray energies and beam positions.
  • The forbidden-reflection 4BD pattern resembles an X-shaped cross and can be captured instantly without moving the crystal.
  • A high-resolution monitoring system for beam and source positions is proposed, which can be applied to synchrotron light sources, X-ray free-electron lasers, and nano-focused X-ray sources.
View Article and Find Full Text PDF

A hybrid deformable x-ray mirror consisting of a mechanical bender and a bimorph deformable mirror has been developed to realize adaptive optical systems, such as zoom condenser optics, for synchrotron-radiation-based x-ray microscopy. In the developed system, both bending mechanisms comprehensively contribute to the formation of the target mirror shape and can narrow the role of piezoelectric actuators, thereby enabling a more stable operation. In this study, the behavior of the bimorph mirror under the clamped condition was investigated, and the sharing of the deformation amount for each bending mechanism was optimized to minimize the amplitude of the voltage distribution of the bimorph mirror.

View Article and Find Full Text PDF

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods.

View Article and Find Full Text PDF

We present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field x-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross section is used for uniformly illuminating samples over a large field of view (FOV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wavefront distortions.

View Article and Find Full Text PDF
Article Synopsis
  • Wavefront-preserving X-ray diamond crystal optics are crucial for X-ray applications, requiring perfectly flat Bragg planes for effective diffraction.
  • Research using X-ray rocking curve imaging revealed that the best synthetic diamond crystals have slope errors of about 0.08 µrad mm, which are slightly larger than the 0.05 µrad mm errors found in perfect silicon crystals.
  • High-temperature annealing at 1450°C can reduce the slope errors in diamond crystals to levels comparable to those of silicon, with further studies underway to assess their wavefront-preservation capabilities.
View Article and Find Full Text PDF

We introduce a new X-ray speckle-vector tracking method for phase imaging, which is based on the wavelet transform. Theoretical and experimental results show that this method, which is called wavelet-transform-based speckle-vector tracking (WSVT), has stronger noise robustness and higher efficiency compared with the cross-correlation-based method. In addition, the WSVT method has the controllable noise reduction and can be applied with fewer scan steps.

View Article and Find Full Text PDF

The results are reported of an X-ray diffraction study of an Si crystal designed and fabricated for very asymmetric diffraction from the 333 reflection for X-ray energies of 8.100 and 8.200 keV.

View Article and Find Full Text PDF

This article describes the development and testing of a novel, water-cooled, active optic mirror system (called "REAL: Resistive Element Adjustable Length") that combines cooling with applied auxiliary heating, tailored to the spatial distribution of the thermal load generated by the incident beam. This technique is theoretically capable of sub-nanometer surface figure error control even at high power density. Tests conducted in an optical metrology laboratory and at synchrotron X-ray beamlines showed the ability to maintain the mirror profile to the level needed for the next generation storage rings and FEL mirrors.

View Article and Find Full Text PDF

Wavefront sensing at X-ray free-electron lasers is important for quantitatively understanding the fundamental properties of the laser, for aligning X-ray instruments and for conducting scientific experimental analysis. A fractional Talbot wavefront sensor has been developed. This wavefront sensor enables measurements over a wide range of energies, as is common on X-ray instruments, with simplified mechanical requirements and is compatible with the high average power pulses expected in upcoming X-ray free-electron laser upgrades.

View Article and Find Full Text PDF

The full radiation from the first harmonic of a synchrotron undulator (between 5 and 12 keV) at the Advanced Photon Source is microfocused using a stack of beryllium compound refractive lenses onto a fast-moving liquid jet and overlapped with a high-repetition-rate optical laser. This micro-focused geometry is used to perform efficient nonresonant X-ray emission spectroscopy on transient species using a dispersive spectrometer geometry. The overall usable flux achieved on target is above 10 photons s at 8 keV, enabling photoexcited systems in the liquid phase to be tracked with time resolutions from tens of picoseconds to microseconds, and using the full emission spectrum, including the weak valence-to-core signal that is sensitive to chemically relevant electronic properties.

View Article and Find Full Text PDF

The MOI (Mutual Optical Intensity) code for propagating partially coherent radiation through beamline optics is updated by including the in-plane wavevector in the wavefield calculation. The in-plane wavevector is a local function and accurately describes the average phase distribution in a partially coherent wavefield. The improved MOI code is demonstrated by beam propagation through free space and non-ideal mirrors.

View Article and Find Full Text PDF

Vibration of optics is one of the major limiting factors of the performance of state-of-the-art beamlines at low-emittance synchrotron facilities. We present a theoretical model with experimental data describing vibration-induced effects on x-ray beam coherence. Owing to the incoherent nature of vibration, the decrease in the beam spatial coherence perturbed by optics vibrations can be characterized by modeling the effective source profile of the vibrating beam.

View Article and Find Full Text PDF

Performance tests of parabolic beryllium refractive lenses, considered as X-ray focusing elements in the future X-ray free-electron laser oscillator (XFELO), are reported. Single and double refractive lenses were subject to X-ray tests, which included: surface profile, transmissivity measurements, imaging capabilities and wavefront distortion with grating interferometry. Optical metrology revealed that surface profiles were close to the design specification in terms of the figure and roughness.

View Article and Find Full Text PDF

A bent Laue double-crystal monochromator system has been designed for vertically expanding the X-ray beam at the Canadian Light Source's BioMedical Imaging and Therapy beamlines. Expansion by a factor of 12 has been achieved without deteriorating the transverse coherence of the beam, allowing phase-based imaging techniques to be performed with high flux and a large field of view. However, preliminary studies revealed a lack of uniformity in the beam, presumed to be caused by imperfect bending of the silicon crystal wafers used in the system.

View Article and Find Full Text PDF