Publications by authors named "LaDisa J"

The past five years have yielded impressive advancements in fully absorbable metal stent technology. The desired ultimate ability for such devices to treat a vascular stenosis without long-term device-related complications or impeding future treatment continues to evoke excitement in clinicians and engineers alike. Nowhere is the need for fully absorbable metal stents greater than in patients experiencing vascular anomalies associated with congenital heart disease (CHD).

View Article and Find Full Text PDF

Severity assessment for coarctation of the aorta (CoA) is challenging due to concomitant morphological anomalies (complex CoA) and inaccurate Doppler-based indices. Promising diagnostic performance has been reported for the continuous flow pressure gradient (CFPG), but it has not been studied in complex CoA. Our objective was to characterize the effect of complex CoA and associated hemodynamics on CFPG in a clinical cohort.

View Article and Find Full Text PDF

The endothelial sodium channel (EnNaC) plays an important role in regulating vessel stiffness. Here, we investigated the regulation of EnNaC in mouse aortic endothelial cells (mAoEC) by the actin cytoskeleton and lipid raft association protein myristoylated alanine-rich C-kinase substrate like protein 1 (MLP1). We hypothesized that mutation of specific amino acid residues within the effector domain of MLP1 or loss of association between MLP1 and the anionic phospholipid phosphate PIP2 would significantly alter membrane association and EnNaC activity in mAoEC.

View Article and Find Full Text PDF

Background: Coarctation of the aorta (CoA) often leads to hypertension posttreatment. Evidence is lacking for the current >20 mm Hg peak-to-peak blood pressure (BP) gradient (BPGpp) guideline, which can cause aortic thickening, stiffening, and dysfunction. This study sought to find the BPGpp severity and duration that avoid persistent dysfunction in a preclinical model and test if predictors translate to hypertension status in patients with CoA.

View Article and Find Full Text PDF

The human body represents a collection of interacting systems that range in scale from nanometers to meters. Investigations from a systems perspective focus on how the parts work together to enact changes across spatial scales, and further our understanding of how systems function and fail. Here, we highlight systems approaches presented at the 2022 Summer Biomechanics, Bio-engineering, and Biotransport Conference in the areas of solid mechanics; fluid mechanics; tissue and cellular engineering; biotransport; and design, dynamics, and rehabilitation; and biomechanics education.

View Article and Find Full Text PDF

Background: Coarctation of the aorta (CoA) often leads to hypertension (HTN) post-treatment. Evidence is lacking for the current >20 mmHg peak-to-peak blood pressure gradient (BPGpp) guideline, which can cause aortic thickening, stiffening and dysfunction. This study sought to find the BPGpp severity and duration that avoid persistent dysfunction in a preclinical model, and test if predictors translate to HTN status in CoA patients.

View Article and Find Full Text PDF

Aims: Severity assessment for coarctation of the aorta (CoA) is challenging due to concomitant morphological anomalies (complex CoA) and inaccurate Doppler-based indices. Promising diagnostic performance has been reported for the continuous flow pressure gradient (CFPG), but it has not been studied in complex CoA. Our objective was to characterize the effect of complex CoA and associated hemodynamics on CFPG in a clinical cohort.

View Article and Find Full Text PDF
Article Synopsis
  • Advances in health care are being driven by 21st-century technologies like artificial intelligence, computational simulations, and extended reality, collectively referred to as AISER.
  • AISER is being applied in cardiovascular therapies for preprocedural planning, virtual clinical trials, and training health care professionals.
  • The review also addresses challenges related to AISER's implementation and highlights the collaboration needed among various experts to enhance its use in cardiovascular medicine.
View Article and Find Full Text PDF

Coarctation of the aorta (CoA; constriction of the proximal descending thoracic aorta) is among the most common congenital cardiovascular defects. Coarctation-induced mechanical perturbations trigger a cycle of mechano-transduction events leading to irreversible precursors of hypertension including arterial thickening, stiffening, and vasoactive dysfunction in proximal conduit arteries. This study sought to identify kinetics of the stress-mediated compensatory response leading to these alterations using a preclinical rabbit model of CoA.

View Article and Find Full Text PDF

Introduction: Congenital heart disease is the leading cause of death related to birth defects and affects 1 out of every 100 live births. Induced pluripotent stem cell technology has allowed for patient-derived cardiomyocytes to be studied in vitro. An approach to bioengineer these cells into a physiologically accurate cardiac tissue model is needed in order to study the disease and evaluate potential treatment strategies.

View Article and Find Full Text PDF

Stent-induced mechanical stimuli cause pathophysiological responses in the coronary artery post-treatment. These stimuli can be minimized through choice of stent, size, and deployment strategy. However, the lack of target lesion material characterization is a barrier to further personalizing treatment.

View Article and Find Full Text PDF

Coarctation of the aorta (CoA) is one of the most common congenital cardiovascular diseases. CoA patients frequently undergo surgical repair, but hypertension (HTN) is still common. The current treatment guideline has revealed irreversible changes in structure and function, yet revised severity guidelines have not been proposed.

View Article and Find Full Text PDF

Researchers conducting computational fluid dynamics (CFD) modeling can spend weeks obtaining imaging data, determining boundary conditions, running simulations and post-processing files. However, results are typically viewed on a 2D display and often at one point in time thus reducing the dynamic and inherently three-dimensional data to a static image. Results from different pathologic states or cases are rarely compared in real-time, and supplementary data are seldom included.

View Article and Find Full Text PDF

The C-type natriuretic peptide receptor (NPRC) is expressed in many cell types and binds all natriuretic peptides with high affinity. Ligand binding results in the activation or inhibition of various intracellular signaling pathways. Although NPRC ligand binding has been shown to regulate various ion channels, the regulation of endothelial sodium channel (EnNaC) activity by NPRC activation has not been studied.

View Article and Find Full Text PDF

Background: Long-term morbidity including hypertension often persists in coarctation patients despite current guidelines. Coarctation severity can be invasively assessed via peak-to-peak catheter pressure gradient (PPCG), which is estimated noninvasively via simplified Bernoulli equation and conventionally reported as peak instantaneous Doppler gradient (PIDG). However, underlying simplifications of the equation limit diagnostic accuracy.

View Article and Find Full Text PDF

Prior computational and imaging studies described changes in flow patterns for patients with Marfan syndrome, but studies are lacking for related populations. This pilot study addresses this void by characterizing wall shear stress (WSS) indices for patients with Loeys-Dietz and undifferentiated connective tissue diseases. Using aortic valve-based velocity profiles from magnetic resonance imaging as input to patient-specific fluid structure interaction (FSI) models, we determined local flow patterns throughout the aorta for four patients with various connective tissue diseases (Loeys-Dietz with the native aorta, connective tissue disease of unclear etiology with native aorta in female and male patients, and an untreated patient with Marfan syndrome, as well as twin patients with Marfan syndrome who underwent valve-sparing root replacement).

View Article and Find Full Text PDF

Needleless connectors (NCs) for vascular access have limited needlestick injuries, but complications including occlusion, thrombosis, and infections have increased despite reduced needlestick injuries. These complications relate to the ability of an NC design to limit volume fluctuations that can lead to fluid reflux with potential for microbial contamination. Different NC designs requiring specific usage protocols and training, a lack of clarity in NC function relative to manufacturer-designated categories, and confounding results from a limited number of studies comparing different NCs have resulted in confusion, ultimately leading to complications from undesirable fluid movement within the vascular access.

View Article and Find Full Text PDF

Anomalous aortic origin of a coronary artery (AAOCA) is the second most common cause of sudden cardiac death in young athletes. One of the hypothesized mechanisms of ischemia in these patients is the lateral compression of the anomalous artery with an intramural or interarterial course. The presence of a narrowing in the anomalous artery will cause physiologic changes in downstream resistance that should be included for computational assessment of possible clinical ramifications.

View Article and Find Full Text PDF
Article Synopsis
  • Extracellular vesicles (EVs) secreted by human aortic endothelial cells (hAoECs) were studied for their role in regulating the endothelial sodium channel (EnNaC), which influences cell stiffness.
  • The research found that EVs from hAoECs enhance EnNaC activity in these cells, particularly those enriched with MARCKS-like protein 1 (MLP1), as opposed to EVs from human fibroblast cells lacking MLP1.
  • A detailed lipid analysis revealed that the lipids in hAoEC-derived EVs were more diverse and included higher concentrations of specific bioactive lipids, suggesting a novel mechanism for EnNaC regulation involving MLP1 and certain lipids. *
View Article and Find Full Text PDF

Bicuspid aortic valve (BAV) is a congenital defect affecting 1-2% of the general population that is distinguished from the normal tricuspid aortic valve (TAV) by the existence of two, rather than three, functional leaflets (or cusps). BAV presents in different morphologic phenotypes based on the configuration of cusp fusion. The most common phenotypes are Type 1 (containing one raphe), where fusion between right coronary and left coronary cusps (BAV R/L) is the most common configuration followed by fusion between right coronary and non-coronary cusps (BAV R/NC).

View Article and Find Full Text PDF

This study computationally assesses the accuracy of an instantaneous wave-free ratio (iFR) threshold range compared to standard modalities such as fractional flow reserve (FFR) and coronary flow reserve (CFR) for multiple intermediate lesions near the left main (LM) coronary bifurcation. iFR is an adenosine-independent index encouraged for assessment of coronary artery disease (CAD), but different thresholds are debated. This becomes particularly challenging in cases of multivessel disease when sensitivity to downstream lesions is unclear.

View Article and Find Full Text PDF

Unroofing surgery for anomalous aortic origin of a coronary artery (AAOCA) alters coronary anatomy by opening the intramural segment so that the anomalous coronary orifice arises perpendicularly from appropriate aortic sinus. Computational fluid dynamics modeling (CFD) allows for quantification of hemodynamics linked to morbidity such as wall shear stress (WSS), relative to patient-specific features like the angle of origin (AO). We hypothesize that CFD will reveal abnormal WSS indices in unroofed arteries that are related to AO.

View Article and Find Full Text PDF

Objective: The objective was to determine the effect of two head-mounted display (HMD) augmented reality (AR) devices on muscle activity and eye strain of electric utility workers. The AR devices were the Microsoft HoloLens and RealWear HMT-1.

Background: The HoloLens is an optical see-through device.

View Article and Find Full Text PDF

Computational modeling of cardiovascular flows is becoming increasingly important in a range of biomedical applications, and understanding the fundamentals of computational modeling is important for engineering students. In addition to their purpose as research tools, integrated image-based computational fluid dynamics (CFD) platforms can be used to teach the fundamental principles involved in computational modeling and generate interest in studying cardiovascular disease. We report the results of a study performed at five institutions designed to investigate the effectiveness of an integrated modeling platform as an instructional tool and describe "best practices" for using an integrated modeling platform in the classroom.

View Article and Find Full Text PDF