Factors such as age and joint structure affect normal wrist motion. The midcarpal joint participates in flexion/extension, radial-ulnar/deviation (RUD), and since lunate/wrist type-2 is likely more stable than a lunate/wrist type-1, we suggest that midcarpal joint structure will affect wrist motion. Our purpose was to compare wrist motion in Caucasian and Japanese populations and to associate motion with midcarpal joint morphology.
View Article and Find Full Text PDFUnlabelled: We studied the association between non-osteoporotic fractures and future major osteoporotic fractures, using UK health records. Non-osteoporotic fractures were found to increase the risk of major osteoporotic fractures, although to a lesser extent than osteoporotic fractures. This highlights the importance of considering all previous fractures in assessing future fracture risk.
View Article and Find Full Text PDFWe report on cases of isolated fourth extensor compartment tenosynovitis without evidence of systemic inflammation that occurred in the context of alteration in the work environment due to the COVID-19 epidemic. Early identification of the deleterious effects of virtual/technologically-dependent work from home can aid in treatment and prevention of these conditions. We describe the phenomenon and suggest a treatment approach.
View Article and Find Full Text PDFJoint replacement arthroplasty for the treatment of thumb osteoarthritis is gaining popularity as recent studies have demonstrated better pinch and grip strength and faster rehabilitation. Our aim was to identify early complications in modern implant designs using a multicenter study. A total of 381 patients who underwent thumb carpometacarpal replacement surgery in six participating hospitals were enrolled.
View Article and Find Full Text PDFIntroduction: Although prevalent, and variable geographically, there is little information on the incidence and risk factors for occupation hand trauma in our health care system. This pilot study was designed to determine the optimal data collection methods for transient risk factors locally METHODS: All adult patients with occupational hand trauma treated at an emergency department (ED) during a three-month period were interviewed, either in person or by phone, using a case crossover designed questionnaire, regarding occupation and exposure to potential transient risk factor.
Results: Of 206 patients treated with occupational trauma during the study period, 94 had trauma distal to the elbow (46%).
The use of three-dimensional (3-D) technology in upper extremity surgery has the potential to revolutionize the way that hand and upper limb procedures are planned and performed. 3-D technology can assist in the diagnosis and treatment of conditions, allowing virtual preoperative planning and surgical templating. 3-D printing can allow the production of patient-specific jigs, instruments and implants, allowing surgeons to plan and perform complex procedures with greater precision and accuracy.
View Article and Find Full Text PDFEur J Orthop Surg Traumatol
August 2023
Purpose: Early diagnosis and treatment of scaphoid fractures is critical to achieve union and prevent wrist degenerative arthritis. Plain radiographic measurements can guide the early approach to suspected fractures. Specifically, the ability to predict fracture or fracture stability from plain radiographs may allow the traumatologist to expand initial referral to three-dimensional imaging.
View Article and Find Full Text PDFJ Hand Surg Eur Vol
June 2022
The article reviews key considerations and our preferred methods in treating upper extremity palsies, gunshot wounds and scaphoid nonunion. For these three difficult conditions, I highlight the importance of a team approach when treating upper extremity neuromuscular disease, flexibility and creativity when treating gunshot wounds, and my personal protocol for dealing with scaphoid fracture nonunions. V.
View Article and Find Full Text PDFIntroduction: This study describes the characteristics of hand trauma treated in community-based emergency centers (CBECs) in Israel. It was hypothesized that the rate of hand trauma, as well as patient and injury characteristics, would differ from a recent study of patients treated in hospital emergency departments (EDs) in Jerusalem.
Methods: Data on all hand injury patients treated at any of the CBECs belonging to a large nationwide chain in 2017 were retrieved from the electronic medical records of the treatment centers, including demographic and clinical characteristics.
Case Report: Quincke sign manifested on the wrist of a young healthy man. The patient had self-treated with topical antibiotics and steroids for a second-degree burn, but then developed contact dermatitis followed by cellulitis. He presented to the emergency department with a "blinking" effect of the skin lesion.
View Article and Find Full Text PDFJ Hand Surg Eur Vol
July 2021
Classifications of scaphoid fractures associate the angle of the fracture with its stability. To examine this assumption, we measured acute scaphoid fracture angles and inclinations in relation to different scaphoid axes, using fracture displacement as an indicator of instability. We examined the effect of using different axes on the measurements of angles.
View Article and Find Full Text PDFCurr Rheumatol Rev
August 2021
Computer modeling of the wrist has followed other fields in the search for descriptive methods to understand the biomechanics of injury. Using patient-specific 3D computer models, we may better understand the biomechanics of wrist fractures in order to plan better care. We may better estimate fracture morphology and stability and evaluate surgical indications, design more adequate or effective surgical approaches and develop novel methods of therapy.
View Article and Find Full Text PDFObjectives: The purpose of the present study was to present an up-to-date report on the prevalence of musculoskeletal complaints in dental hygienists and dental hygiene students in Israel. It examined the areas of the body that were most frequently affected and the intensity of pain in both groups. The possible differences between groups and the likelihood that musculoskeletal symptoms in students can be attributed to their workload.
View Article and Find Full Text PDFUsing three-dimensional (3D) computed tomography models of acute scaphoid fractures, we looked for differences between volumetric size of the fracture fragments, recognizable groups, or a shared common fracture area. We studied 51 patients with an adequate computed tomography scan of an acute scaphoid fracture using 3D modeling. Fracture surfaces were identified and fragment volumetric size of the fracture fragments was measured.
View Article and Find Full Text PDFPurpose: In scaphoid fracture screw fixation, the screw is commonly placed along the long axis of the bone, without consideration of the fracture plane. This position is not perpendicular to transverse waist fractures or to the more common horizontal oblique fractures. Our aim was to examine the feasibility and describe possible approaches to, placing a screw perpendicular and in the center of the scaphoid waist fracture.
View Article and Find Full Text PDFBackground: Wrist and hand injuries are common and constitute a major economic burden. General injury prevention programs have failed to demonstrate a decrease in injury rates. We hypothesized that there are differences in injury patterns in culturally diverse subpopulations of a metropolitan area treated within the same medical system, which may partly explain the difficulties associated with injury prevention.
View Article and Find Full Text PDFBackground: Trigger finger (TF) is a common hand pathology frequently encountered in hand clinics. Occupational therapists predominantly assess TF symptoms as opposed to using standardized hand functioning assessments. The purpose of this study was to assess the construct validity of dexterity and grip strength assessments for clients with TF.
View Article and Find Full Text PDFPurpose: The recommended technique for the fixation of a scaphoid waist fracture involves a headless compression screw placed in the proximal fragment center. This is usually accomplished by placing a longitudinal axis screw as visualized by fluoroscopy. The screw length has been shown to have a biomechanical advantage.
View Article and Find Full Text PDF