Publications by authors named "L Wagnert-Avraham"

Introduction: Many trauma patients die from hemorrhagic shock in the military and civilian settings. Although two-thirds of hemorrhagic shock victims die of reasons other than exsanguination, such as the consequent cytokine storm, anti-inflammatory therapies failed to be utilized. Apoptotic cell-based treatments enhance innate ability to exert systemic immunomodulation as demonstrated in several clinical applications and hence might present a novel approach in hemorrhagic shock treatment.

View Article and Find Full Text PDF

Combat soldiers are currently faced with using a hearing-protection device (HPD) at the cost of adequately detecting critical signals impacting mission success. The current study tested the performance of the Perforated-Concave-Earplug (pCEP), a proof-of-concept passive HPD consisting of a concave bowl-like rigid structure attached to a commercial roll-down earplug, designed to improve sound localization with minimal compromising of noise attenuation. Primarily intended for combat/military training settings, our aim was an evaluation of localization of relevant sound sources (single/multiple gunfire, continuous noise, spoken word) compared to 3M™-Combat-Arms™4.

View Article and Find Full Text PDF

Remote ischemic preconditioning (RIPC) involves deliberate, brief interruptions of blood flow to increase the tolerance of distant critical organs to ischemia. This study tests the effects of limb RIPC in a porcine model of controlled hemorrhage without replacement therapy simulating an extreme field situation of delayed evacuation to definitive care. Twenty-eight pigs (47 ± 6 kg) were assigned to: (1) control, no procedure (n = 7); (2) HS = hemorrhagic shock (n = 13); and (3) RIPC + HS = remote ischemic preconditioning followed by hemorrhage (n = 8).

View Article and Find Full Text PDF

Background: This prospective study evaluated the effect of routine, uncontrolled, Israeli field storage conditions on the safety and efficacy of Lyo-Plas N Freeze-Dried Plasma (FDP) at the end of the manufacturer's shelf life, and up to 24 months post expiry. Clotting factors V, VIII and XI, proteins S, C, fibrinogen, PTT, ATIII, VWF, and INR as well as TEG, DDM, residual moisture, pH, and sterility of FDP returned from field units after uncontrolled storage were evaluated.

Study Design And Methods: Parameters measured at the end of manufacturer shelf life, as well as 6, 12, 18, and 24 months after expiry, were compared to those of freshly supplied FDP doses.

View Article and Find Full Text PDF

Hemorrhagic shock is the number one cause of death on the battlefield and in civilian trauma as well. Mathematical modeling has been applied in this context for decades; however, the formulation of a satisfactory model that is both practical and effective has yet to be achieved. This paper introduces an upgraded version of the 2007 Zenker model for hemorrhagic shock termed the ZenCur model that allows for a better description of the time course of relevant observations.

View Article and Find Full Text PDF