Publications by authors named "L Rysava"

Polymeric foams tailor-made of polyvinylpyrrolidone (PVP) and carboxymethylcellulose/oxidized 6-carboxycellulose (CMC07/OC) composite were proposed as suitable sorbents for the collection and analysis of dried blood spots (DBSs). The PVP and CMC07/OC foams were easy to prepare, enabled collection of minute volumes of capillary blood, and blood drying at ambient temperature. The resulting foams were prepared as small porous discs with uniform dimensions (approx.

View Article and Find Full Text PDF

Direct analysis of complex samples is demonstrated by the at-line coupling of hollow fiber liquid-phase microextraction (HF-LPME) to capillary electrophoresis (CE). The hyphenation of the preparative and the analytical technique is achieved through a 3D-printed microextraction device with an HF located in a sample vial of a commercial CE instrument. The internal geometry of the device guides the CE separation capillary into the HF and the CE injection of the HF-LPME extract is performed directly from the HF lumen.

View Article and Find Full Text PDF

A simple and convenient concept of blood sampling followed by a fully automated analysis is presented. A disposable sampling kit is used for accurate self-sampling of capillary blood from a finger prick. A high-throughput blood sampling is thus enabled, which is essential in many clinical assays and considerably improves life quality and comfort of involved subjects.

View Article and Find Full Text PDF

A simple and cheap all-in-one concept for at-line coupling of hollow fiber liquid-phase microextraction (HF-LPME) to commercial capillary electrophoresis (CE) is demonstrated, which enables the direct analysis of complex samples. A disposable microextraction device compatible with injection systems of Agilent CE instruments is proposed, which consists of a short segment of a porous HF attached to a tapered polypropylene holder. The holder maintains a constant position of the HF in a CE vial during extraction and simultaneously guides the injection end of a separation capillary into the HF lumen for automated CE injection and analysis.

View Article and Find Full Text PDF

Blood volume in dried blood spot (DBS) analysis is assumed to be constant for DBS punches with a fixed area. However, blood volume in the punch is dependent on several factors associated with the blood composition and is preferentially normalized by off-line analysis for quantitative purposes. Instead of using external instrumentation, we present an all-in-one approach for the simultaneous determination of exact blood volume in the DBS punch and the quantitation of target analytes.

View Article and Find Full Text PDF