Purpose: To describe a technique for flexion gap management in total knee arthroplasty (TKA) using conventional instrumentation with minimal soft tissue release, by aligning the femoral component to restore close-to-native posterior condylar angle (PCA). The hypothesis was that this technique renders consistent outcomes, regardless the preoperative deformity or intraoperative parameters.

Methods: In a consecutive series of 152 TKAs, the femoral component was rotated to restore anatomic PCA of 2° ± 2° and the flexion gap was balanced with a final lateral flexion laxity of 1-3 mm.

View Article and Find Full Text PDF

Introduction: Avascular necrosis of the femoral head often progresses to femoral head collapse if not treated. Conservative treatment yields highly variable results and is not standardised, mainly because it is typically evaluated in small patient populations. This led us to conduct a large retrospective comparative study with the goals of 1) analysing survival and functional outcomes, 2) looking for differences in survival between core decompression techniques (standard versus augmented), and 3) studying the risk factors for femoral head collapse and revision by arthroplasty.

View Article and Find Full Text PDF

Background: The purpose of this prospective matched paired study is to compare the in vivo migration patterns using Ein Bild Roentgen Analyze femoral component of shortened vs standard-length stems cemented line-to-line in primary total hip arthroplasty (THA) at 2-year follow-up.

Methods: We prospectively included the first 50 consecutive primary cemented THAs in 50 patients using a 12% shortened stem (AmisK group) of which design was derived from the original Charnley-Kerboull (CK) femoral components. These 50 patients were matched paired to 50 patients from a historical series of patients who underwent primary THAs using standard-length CK stems (CK group) with available long-term results, including Ein Bild Roentgen Analyze femoral component data at 2-year follow-up.

View Article and Find Full Text PDF

Acetabular revisions with severe bone defects can be challenging procedures. Several grading systems have been set into place to help the surgeon adequately gauge the degree of bone loss within the acetabulum. Internationally innovative research in orthopedics and bio-engineering has helped with progression of successful techniques and rings to re-establish the normal anatomy of the hip.

View Article and Find Full Text PDF

Objective: Cement thickness of at least 2 mm is generally associated with more favorable results for the femoral component in cemented hip arthroplasty. However, French-designed stems have shown favorable outcomes even with thin cement mantle. The biomechanical behaviors of a French stem, Charnley-Marcel-Kerboull (CMK) and cement were researched in this study.

View Article and Find Full Text PDF