Publications by authors named "L Ficcadenti"

Purpose: In order to translate the FLASH effect in clinical use and to treat deep tumors, Very High Electron Energy irradiations could represent a valid technique. Here, we address the main issues in the design of a VHEE FLASH machine. We present preliminary results for a compact C-band system aiming to reach a high accelerating gradient and high current necessary to deliver a Ultra High Dose Rate with a beam pulse duration of 3μs.

View Article and Find Full Text PDF

Purpose: One of the obstacles to the application of Boron Neutron Capture Therapy (BNCT) and Proton Boron Fusion Therapy (PBFT) concerns the measurement of borated carriers' biodistribution. The objective of the present study was to evaluate the in vitro internalization of the F-labelled p-boronophenylalanine (F-BPA) in the human cancer pancreatic cell line (PANC-1) for the potential application of BNCT and PBFT in pancreatic cancer. The F-BPA carrier has the advantage that its bio-distribution may be monitored in vivo using F-Nuclear Magnetic Resonance (F NMR).

View Article and Find Full Text PDF

We report the first experimental implementation of a method based on simultaneous use of an energy chirp in the electron beam and a tapered undulator, for the generation of ultrashort pulses in a self-amplified spontaneous emission mode free-electron laser (SASE FEL). The experiment, performed at the SPARC FEL test facility, demonstrates the possibility of compensating the nominally detrimental effect of the chirp by a proper taper of the undulator gaps. An increase of more than 1 order of magnitude in the pulse energy is observed in comparison to the untapered case, accompanied by FEL spectra where the typical SASE spiking is suppressed.

View Article and Find Full Text PDF

In this Letter we report the first experiments aimed at the simultaneous demonstration of the emittance compensation process and velocity bunching in a high brightness electron source, the SPARC photoinjector in INFN-LNF. While a maximum compression ratio up to a factor 14 has been observed, in a particular case of interest a compression factor of 3, yielding a slice current of 120 A with less than 2 microm slice emittance, has been measured. This technique may be crucial in achieving high brightness beams in photoinjectors aiming at optimized performance of short wavelength single-pass free electron lasers or other advanced applications in laser-plasma accelerators.

View Article and Find Full Text PDF

In this Letter we report the first experimental observation of the double emittance minimum effect in the beam dynamics of high-brightness electron beam generation by photoinjectors; this effect, as predicted by the theory, is crucial in achieving minimum emittance in photoinjectors aiming at producing electron beams for short wavelength single-pass free electron lasers. The experiment described in this Letter was performed at the SPARC photoinjector site, during the first stage of commissioning of the SPARC project. The experiment was made possible by a newly conceived device, called an emittance meter, which allows a detailed and unprecedented study of the emittance compensation process as the beam propagates along the beam pipe.

View Article and Find Full Text PDF