Publications by authors named "L F Lastras-Martinez"

Article Synopsis
  • The study reveals that off-axis optical rays in spatially resolved reflectance anisotropy (RA) spectrometers create unwanted signal components that standard optical alignment cannot fix, related to sample reflectivities.
  • The nature of these spurious signals is complex and influenced by where the light hits the sample surface.
  • A new data-reduction method using singular value decomposition is introduced to identify and eliminate these spurious signals, and the method was validated through an 8 × 8 multi-anode photomultiplier setup that enhances signal quality.
View Article and Find Full Text PDF

Reflectance anisotropy spectroscopy (RAS) is a highly sensitive optical probe for the real-time study of the epitaxial growth of zincblende semiconductors. Here we report on (1) non-equilibrium RAS spectra acquired in real time during the homoepitaxial growth of GaAs, and (2) RAS spectra for GaAs surfaces under equilibrium with several arsenic overpressures. We show that in both cases RAS spectra can be decomposed into two basic components, each with a characteristic line shape.

View Article and Find Full Text PDF

Photoreflectance-difference (PR/PRD) and reflectance-difference (RD) spectroscopies employ synchronic detection usually with lock-in amplifiers operating at moderate (200-1000 Hz) and high (50-100 KHz) modulation frequencies, respectively. Here, we report a measurement system for these spectroscopies based on a multichannel CCD spectrometer without a lock-in amplifier. In the proposed scheme, a typical PRD or RD spectrum consists of numerical subtractions between a thousand CCD captures recorded, while a photoelastic modulator is either operating or inhibited.

View Article and Find Full Text PDF

The structural characterization of capillary microfluidic chips is important for reliable applications. In particular, nondestructive diagnostic tools to assess geometrical dimensions and their correlations with control processes are of much importance, preferably if they are implemented in situ. Several techniques to accomplish this task have been reported; namely, optical coherence tomography (OCT) jointly with confocal fluorescence microscopy (CFM) to investigate internal features of lab-on-a-chip technologies.

View Article and Find Full Text PDF

We report on a rapid, 32-channel reflectance-difference (RD) spectrometer with sub-second spectra acquisition times and ΔR/R sensitivity in the upper 10(-4) range. The spectrometer is based on a 50 kHz photo-elastic modulator for light polarization modulation and on a lock-in amplifier for signal harmonic analysis. Multichannel operation is allowed by multiplexing the 32 outputs of the spectrometer into the input of the lock-in amplifier.

View Article and Find Full Text PDF