Purpose: The relationship between retinal morphology, as assessed by optical coherence tomography (OCT), and retinal function in microperimetry (MP) has not been well studied, despite its increasing importance as an essential functional endpoint for clinical trials and emerging therapies in retinal diseases. Normative databases of healthy ageing eyes are largely missing from literature.
Methods: Healthy subjects above 50 years were examined using two MP devices, MP-3 (NIDEK) and MAIA (iCare).
Purpose: Growing interest in microperimetry (MP) or fundus-controlled perimetry as a targeted psychometric testing method in geographic atrophy (GA) is warranted because of the disease subclinical/extrafoveal appearance or preexisting foveal loss with visual acuity becoming unreliable. We provide comprehensive pointwise test-retest repeatability reference values on the most widely used MP devices and combine them with targeted testing in areas of retinal pigment epithelium (RPE) as well as photoreceptor (PR) integrity loss, guiding the interpretation of sensitivity loss during the long-term follow-up of patients with GA.
Design: Prospective reliability study.
Background: Despite years of medical research, cancer remains a major public health problem worldwide, particularly in Africa. The cost, duration, and toxicity of currently available treatments are all drawbacks. Plant secondary metabolites are significant anticancer compounds.
View Article and Find Full Text PDFPurpose: In this study, differences in retinal feature visualization of high-resolution optical coherence tomography (OCT) devices were investigated with different axial resolutions in quantifications of retinal pigment epithelium and photoreceptors (PRs) in intermediate age-related macular degeneration.
Methods: Patients were imaged with standard SPECTRALIS HRA + OCT and the investigational High-Res OCT device (both by Heidelberg Engineering, Heidelberg, Germany). Drusen, retinal pigment epithelium, and PR layers were segmented using validated artificial intelligence-based algorithms followed by manual corrections.
Objective: To compare the visibility and accessibility of the outer retina in neovascular age-related macular degeneration (nAMD) between 2 OCT devices.
Methods: In this prospective, cross-sectional exploratory study, differences in thickness and loss of individual outer retinal layers in eyes with nAMD and in age-matched healthy eyes between a next-level High-Res OCT device and the conventional SPECTRALIS OCT (both Heidelberg Engineering GmbH, Heidelberg, Germany) were analyzed. Eyes with nAMD and at least 250 nL of retinal fluid, quantified by an approved deep-learning algorithm (Fluid Monitor, RetInSight, Vienna, Austria), fulfilled the inclusion criteria.