Background: Irrigation of the pulp space is a mandatory step to get rid of all its organic and inorganic content. Activation of the irrigants play a key role in the era of minimally invasive endodontics. The aim of this study was to assess the effectiveness of different irrigants activation methods in removing the smear layer at 1, 3, 5 and 8 mm from the apex from conservatively shaped canals.
View Article and Find Full Text PDFThis study evaluated the surface microhardness of Lucirin-TPO (TPO) containing resin based composite (RBC) cured with three light-emitting diode (LED) light curing units (LCUs) (two single-peak LED and one multi-peak LED), and two different energy density (ED) (8 J/cm and 16 J/cm). Ninety specimens (8 mm wide and 2 mm thick) (n=5), were prepared with three different shades: translucent (T), A2 dentin (A2d), and A4 dentin (A4d). Specimens were subjected to micro-hardness Vickers measurements (Vickers Hardness Number, VHN) on both top and bottom surfaces.
View Article and Find Full Text PDFObjectives: This study was to compare the efficacy of EndoActivator, EndoVac, PUI, and LAI methods in removing the smear layer from root canals.
Materials And Methods: Eighty single-rooted mandibular premolars were decoronated to a standardized length of 15 mm. Specimens were shaped to ProTaper F4 (Dentsply Maillefer) and irrigated with 5.
Eur J Paediatr Dent
December 2016
Aim: The aim of this study was to determine the chemical composition and the phases' microstructure of Aureoseal Plus (OGNA, Italy) and ProRoot MTA (Dentsply Tulsa Dental, USA) and to compare their characteristics.
Materials And Methods: Study Design: Comparing Aureoseal Plus and ProRoot MTA microstructure by means of several analyses type. The chemical analysis of the two cements was assessed following the UNI EN ISO 196-2 norm.
Introduction: This ex vivo study evaluated the accuracy of the Root ZX electronic apex locator (EAL) (J Morita Corp, Kyoto, Japan) in determining the working length during retreatment of canals sealed with 2 different carrier-based obturating materials (ProTaper Obturator [Dentsply Maillefer, Ballaigues, Switzerland] and GuttaCore [Dentsply Maillefer]) and also evaluated whether they influenced its accuracy differently.
Methods: Fifty extracted single-rooted human teeth with sound apices were selected for the study. We measured canals with the direct visual technique using a #10 K-file and shaped them with ProTaper Universal instruments (Dentsply Maillefer) up to this predetermined length.