Over the past 20 years, several eye-tracking technologies have been developed. This article aims to present a new type of eye tracker capable of producing detailed information on eye and head movements using an array of magnetoresistive detectors fixed on the patient's head and a small magnet inserted into a contact lens, adapted to the curvature of the cornea of the subject. The software used for data analysis can combine or compare eye and head movements and can represent them as 2D or 3D images.
View Article and Find Full Text PDFWe present a set of results obtained with an innovative eye-tracker based on magnetic dipole localization by means of an array of magnetoresistive sensors. The system tracks both head and eye movements with a high rate (100-200 Sa/s) and in real time. A simple setup is arranged to simulate head and eye motions and to test the tracker performance under realistic conditions.
View Article and Find Full Text PDFBackground: Hereditary angioedema (HAE) due to C1 esterase inhibitor deficiency (C1-INH-HAE) is characterized by recurrent swelling attacks. A European treatment registry was established to review the adverse event profile and efficacy of recombinant human C1 esterase inhibitor (rhC1-INH) for HAE attacks.
Methods: Individuals with C1-INH-HAE were enrolled following a decision to treat with rhC1-INH and provision of written informed consent.
On January 14, 2019, the Major Atmospheric Gamma Imaging Cherenkov telescopes detected GRB 190114C above 0.2 TeV, recording the most energetic photons ever observed from a gamma-ray burst. We use this unique observation to probe an energy dependence of the speed of light in vacuo for photons as predicted by several quantum gravity models.
View Article and Find Full Text PDFBackground: In spite the instinct social&financial impact of Leg Length Discrepancy (LLD), controversial and conflicting results still exist regarding a reliable assessment/correction method. For proper management it's essential to discriminate between anatomical&functional Leg Length Discrepancy (FLLD). With the newly invented NPoS (New Postural Solution), under the umbrella of the collaboration of PRM Department, Tor Vergata University with Baro Postural Instruments srl, positive results were observed in both measuring& compensating the hemi-pelvic antero-medial rotation in FLLD through personalized bilateral heel raise using two NPoS components: Foot Image System (FIS) and Postural Optimizer System (POS).
View Article and Find Full Text PDF