Publications by authors named "L Begnozzi"

Purpose: Retrospective analysis of 3D clinical treatment plans to investigate qualitative, possible, clinical consequences of the use of PBC versus AAA.

Methods: The 3D dose distributions of 80 treatment plans at four different tumour sites, produced using PBC algorithm, were recalculated using AAA and the same number of monitor units provided by PBC and clinically delivered to each patient; the consequences of the difference on the dose-effect relations for normal tissue injury were studied by comparing different NTCP model/parameters extracted from a review of published studies. In this study the AAA dose calculation is considered as benchmark data.

View Article and Find Full Text PDF

In this article, a three-dimensional inversion recovery sequence was optimized with the aim of generating in vivo volume T(1) maps of the heart using a 1.5-T MR system. Acquisitions were performed before and after gadolinium diethylenetriamine penta-acetic acid (Gd-DTPA) administration in one patient with hypertrophic cardiomyopathy and in two healthy volunteers.

View Article and Find Full Text PDF

Purpose: Retrospective study of 3D clinical treatment plans based on radiobiological considerations in the choice of the reference dose level from tumor dose-volume histograms.

Methods And Materials: When a radiation oncologist evaluates the 3D dose distribution calculated by a treatment planning system, a decision must be made on the percentage dose level at which the prescribed dose should be delivered. Much effort is dedicated to deliver a dose as uniform as possible to the tumor volume.

View Article and Find Full Text PDF

Although more advanced techniques such as intensity-modulated radiotherapy are rapidly spreading, 3D conformal radiotherapy (3D-CRT) remains the standard of treatment for many diseases. The authors outline essential indications to guarantee the quality of 3D-CRT treatments. Criteria for clinical indications and potential clinical advantages and disadvantages of 3D-CRT technology are presented.

View Article and Find Full Text PDF

The Gafchromic XR type R film is a suitable dosimeter to determine the map of the skin dose in patients undergone complex interventional radiological procedures, such as cardiology ones. The need of preventing or locating possible skin injuries due to high doses administered to patients-as recommended by international organizations-wants the introduction in patient dosimetry of a dosimeter easy to handle, with low dependence of the response on energy in the typical radiological range, and extended measurable dose range. XR type R films fulfil all these requirements and moreover may be quickly analyzed by cheap commercial scanners.

View Article and Find Full Text PDF