The local lymph node assay using 5-bromo-2-deoxyuridine with flow cytometry (LLNA: BrdU-FCM) is a modified LLNA used to identify skin sensitizers. This assay measures the proliferation of auricular lymph node cells (LNCs) during the induction phase of skin sensitization and the number of BrdU-positive LNCs using flow cytometry. We determined if LLNA: BrdU-FCM can evaluate the skin sensitization potential of 20 substances, including 16 sensitizers and 4 non-sensitizers, that were tested using LLNA: DA and LLNA: BrdU-ELISA but not listed in OECD TG 429.
View Article and Find Full Text PDFThe need for in vitro eye irritation test replacing in vivo is steadily increasing. The MCTT HCE™ eye irritation test (EIT) using 3D reconstructed human cornea-like epithelium, was developed to identify ocular irritants from non-irritants those that are not requiring classification and labelling for eye irritation. Here, we report the results of me-too validation study, which was conducted to evaluate the reliability and relevance of the MCTT HCE EIT, according to performance standards (PS) of OECD TG 492.
View Article and Find Full Text PDFAlthough alternative test methods based on the 3Rs (Replacement, Reduction, Refinement) are being developed to replace animal testing in reproductive and developmental toxicology, they are still in an early stage. Consequently, we aimed to develop alternative test methods in male animals using mouse spermatogonial stem cells (mSSCs). Here, we modified the OECD TG 489 and optimized the comet assay in our previous study.
View Article and Find Full Text PDFWith ultraviolet and visible light exposure, some pharmaceutical substances applied systemically or topically may cause phototoxic skin irritation. The major factor in phototoxicity is the generation of reactive oxygen species (ROS) such as singlet oxygen and superoxide anion that cause oxidative damage to DNA, lipids and proteins. Thus, measuring the generation of ROS can predict the phototoxic potential of a given substance indirectly.
View Article and Find Full Text PDFThe local lymph node assay using 5-bromo-2-deoxyuridine (BrdU) with flow cytometry (LLNA: BrdU-FCM) is a modified LLNA that is used to identify skin sensitizers by counting BrdU-incorporated lymph node cells (LNCs) with flow cytometry. Unlike other LLNA methods (OECD TG 429, 442A and 442B) in which the CBA/J mouse strain is used, LLNA: BrdU-FCM was originally designed to be compatible with BALB/c, a mouse strain that is more widely used in many countries. To justify the substitution of CBA/J for BALB/c, the equivalence of the test results between two strains shall be established prior to the official implementation of LLNA: BrdU-FCM.
View Article and Find Full Text PDFFood Addit Contam Part A Chem Anal Control Expo Risk Assess
April 2015
A simple and rapid method was developed and validated for the determination of hexamethylenetetramine (HMT) in foods. Samples were homogenised and extracted with methanol, followed by centrifugation. The resulting solution was filtered and injected into the high-performance liquid chromatograph (HPLC).
View Article and Find Full Text PDF