Objectives: With the rapidly aging world population, Japan has many older people with difficulties in maintaining oral health. This study aimed to investigate the relationship between dietary hardness score and performance of activities of daily living (ADL) of 90-year-old individuals in rural areas of Japan.
Material And Methods: A total of 236 individuals (64 men and 172 women) aged 90 years in Mitsugi town, Hiroshima, Japan, were included.
Background: Bone quality is as important as bone mineral density in terms of bone strength. Bone turnover markers (BTMs) are clinical indicators of bone quality. In implant dentistry, bone quality is considered equivalent to bone density on radiographic assessments.
View Article and Find Full Text PDFThe purpose of this study was to establish an acid-etching procedure for altering the Ca/P ratio of the nanostructured surface of hydroxyapatite (HAP) by using surface chemical and morphological analyses (XPS, XRD, SEM, surface roughness, and wettability) and to evaluate the in vitro response of osteoblast-like cells (MC3T3-E1 cells) to the modified surfaces. This study utilized HAP and HAP treated with 10%, 20%, 30%, 40%, 50%, or 60% phosphoric acid solution for 10 minutes at 25°C, followed by rinsing 3 times with ultrapure water. The 30% phosphoric acid etching process that provided a Ca/P ratio of 1.
View Article and Find Full Text PDFThe purpose of this study was to evaluate preoperative CT-derived bone densities in Hounsfield units (HU) at implant sites that acquired primary stability, and to compare these values to the optimal bone densities proposed in the literature. Fifty-one patients, 18 males (37 implant sites) and 33 females (67 implant sites) between 2003 and 2010 were assessed. CT data for different jaw sections, regions, and operating procedures were compared using the Kruskal-Wallis test and Scheffe's test for multiple comparisons (P < 0.
View Article and Find Full Text PDFDue to the high corrosion resistance and strength to density ratio titanium is widely used in industry, and also in a gamut of medical applications. Here we report for the first time on our development of a titanium passivation layer sensor that makes use of surface plasmon resonance (SPR). The deposited titanium metal layer on the sensor was passivated in air, similarly to titanium medical devices.
View Article and Find Full Text PDFThe purpose of this study was to measure the time-dependent chemical interaction between synthetic RGDS(PO(3)H(2))PA (P-RGD) peptide and titanium surfaces using a titanium surface plasmon resonance (SPR) biosensor and to determine the degree of peptide immobilization on the surfaces. An SPR instrument for 'single-spot' analysis was used for nanometer-scale detection of biomolecular adsorption using a He-Ne laser light according to Knoll's method. The oxidized titanium surface was etched when exposed to H(3)PO(4) solutions with a pH of 2.
View Article and Find Full Text PDFThe purpose of this study was to characterize the chemical interaction between titanium surfaces and the peptide RGDS(PO(3)H(2))PA (P-RGD) synthesized from RGD peptide (RGD) and o-phospho-L-serine (P-Ser), and to determine the degree of peptide immobilization on the titanium surface. X-ray photoelectron spectroscopy showed that the adsorption amount of RGD was significantly smaller than those of P-Ser and P-RGD (p<0.05).
View Article and Find Full Text PDFAn index was developed to estimate the residual periodontal ligament support for individual teeth during treatment planning for partially edentulous patients. The Residual Periodontal Ligament Index (rPLI) was derived from a formula that calculates the remaining area of periodontal attachment and the Normal Periodontal Ligament Index (nPLI). To illustrate the applicability of the rPLI, the total nPLI scores of the remaining teeth corresponding to Eichner subclasses of partial edentulism were charted by assessing the average occlusal support numerically.
View Article and Find Full Text PDFThe purpose of this study was to investigate the chemical interaction between titanium implant surface and amino acids. Pure titanium disks were pretreated with 10 N HCl and ultrapure water at room temperature for 30 minutes each. Disks were then modified with one of the three amino acids--L-aspartic acid, L-serine, or L-threonine--at 37 degrees C for 12 hours.
View Article and Find Full Text PDFThe purpose of this study was to investigate a new biochemical surface modification technique for titanium implants using phospho-amino acid. Pure titanium disks were pretreated with 10 N HCl and ultrapure water at room temperature for 30 minutes respectively. Then these disks were modified with either L-threonine (Thr) or O-phospho-L-threonine (P-Thr) at 37 degrees C for 12 hours.
View Article and Find Full Text PDFPurpose: It is well-recognized that many institutionalized elderly persons with dementia do not wear dentures. The objective of this study was to evaluate the current status of denture use among elderly patients with dementia, in association with degree of mental impairment, to provide information relating to a decision-making process for optimal denture treatment.
Materials And Methods: From August 2001 to December 2002, 101 hospitalized elderly persons in a geriatric hospital dental clinic received removable denture treatment by two certified prosthodontists.
Nihon Hotetsu Shika Gakkai Zasshi
April 2005
Patient: The patient (57-years-old female) suffered from severe chronic periodontitis in the maxillary and mandibular molar regions. After extraction of these teeth, treatment dentures were immediately placed in the maxilla and mandible to restore the occlusal-supporting area. Final denture treatment was done by adjusting the provisional dentures according to the patient's concern.
View Article and Find Full Text PDF