We report on the neuromorphic sound localization circuit which can enhance the perceptual sensation in a hearing aid system. All elements are simple leaky integrate-and-fire neuron circuits with different parameters optimized to suppress the impacts of synaptic circuit noises. The detection range and resolution of the proposed neuromorphic circuit are 500 us and 5 us, respectively.