Volumetric 3D printing motivated by computed axial lithography enables rapid printing of homogeneous parts but requires a high dimensionality gradient-descent optimization to calculate image sets. Here we introduce a new, simpler approach to image-computation that algebraically optimizes a model of the printed object, significantly improving print accuracy of complex parts under imperfect material and optical precision by improving optical dose contrast between the target and surrounding regions. Quality metrics for volumetric printing are defined and shown to be significantly improved by the new algorithm.
View Article and Find Full Text PDFVolumetric additive manufacturing (VAM) forms complete 3D objects in a single photocuring operation without layering defects, enabling 3D printed polymer parts with mechanical properties similar to their bulk material counterparts. This study presents the first report of VAM-printed thiol-ene resins. With well-ordered molecular networks, thiol-ene chemistry accesses polymer materials with a wide range of mechanical properties, moving VAM beyond the limitations of commonly used acrylate formulations.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
October 2017
The goal for positron emission tomography (PET)/X is measuring changes in radiotracer uptake for early assessment of response to breast cancer therapy. Upper bounds for detecting such changes were investigated using simulation and two image reconstruction algorithms customized to the PET/X rectangular geometry. Analytical reconstruction was used to study spatial resolution, comparing results with the distance of the closest approach (DCA) resolution surrogate that is independent of the reconstruction method.
View Article and Find Full Text PDFPurpose: The authors discuss the design and evaluate the performance of combined event estimation and image reconstruction algorithms designed for a proposed high-resolution rectangular breast PET scanner (PETX). The PETX scanner will be capable of measuring the depth of interaction by utilizing detector modules composed of depth-of-interaction microcrystal element (dMiCE) crystal pairs. This design allows a unique combination of event estimation and fast projection methods.
View Article and Find Full Text PDFIn this paper we consider the task of image reconstruction in positron emission tomography (PET) with the planogram frequency-distance rebinning (PFDR) algorithm. The PFDR algorithm is a rebinning algorithm for PET systems with panel detectors. The algorithm is derived in the planogram coordinate system which is a native data format for PET systems with panel detectors.
View Article and Find Full Text PDFPurpose: In cardiac PET and PET/CT imaging, misaligned transmission and emission images are a common problem due to respiratory and cardiac motion. This misalignment leads to erroneous attenuation correction and can cause errors in perfusion mapping and quantification. This study develops and tests a method for automated alignment of attenuation and emission data.
View Article and Find Full Text PDFWe develop a statistical line of response (LOR) estimator of the three-dimensional interaction positions of a pair of annihilation photons in a PET detector module with depth of interaction capability. The three-dimensional points of interaction of a coincidence pair of photons within the detector module are estimated by calculation of an expectation of the points of interaction conditioned on the signals measured by the photosensors. This conditional expectation is computed from estimates of the probability density function of the light collection process and a model of the kinetics of photon interactions in the detector module.
View Article and Find Full Text PDFIEEE Nucl Sci Symp Conf Rec (1997)
February 2009
Our laboratory is developing a high-resolution PET detector capable of providing depth-of-interaction information (dMiCE) by tailoring the light sharing between two adjacent detector elements. Each detector element in the prototype system has a 2×2 mm(2) cross section and is directly coupled to a micro-pixel avalanche photodiode (MAPD). In this setup the distribution of the ratio of light shared between two adjacent detector elements can be expressed as a function of the depth of interaction.
View Article and Find Full Text PDF