Publications by authors named "Kyle L McMillan"

Purpose: Using common datasets, to estimate and compare the diagnostic performance of image-based denoising techniques or iterative reconstruction algorithms for the task of detecting hepatic metastases.

Methods: Datasets from contrast-enhanced CT scans of the liver were provided to participants in an NIH-, AAPM- and Mayo Clinic-sponsored Low Dose CT Grand Challenge. Training data included full-dose and quarter-dose scans of the ACR CT accreditation phantom and 10 patient examinations; both images and projections were provided in the training data.

View Article and Find Full Text PDF

The use of iterative reconstruction (IR) algorithms in CT generally decreases image noise and enables dose reduction. However, the amount of dose reduction possible using IR without sacrificing diagnostic performance is difficult to assess with conventional image quality metrics. Through this investigation, achievable dose reduction using a commercially available IR algorithm without loss of low contrast spatial resolution was determined with a channelized Hotelling observer (CHO) model and used to optimize a clinical abdomen/pelvis exam protocol.

View Article and Find Full Text PDF

The use of Monte Carlo simulations in diagnostic medical imaging research is widespread due to its flexibility and ability to estimate quantities that are challenging to measure empirically. However, any new Monte Carlo simulation code needs to be validated before it can be used reliably. The type and degree of validation required depends on the goals of the research project, but, typically, such validation involves either comparison of simulation results to physical measurements or to previously published results obtained with established Monte Carlo codes.

View Article and Find Full Text PDF

Purpose: In AAPM Task Group 204, the size-specific dose estimate (SSDE) was developed by providing size adjustment factors which are applied to the Computed Tomography (CT) standardized dose metric, CTDI(vol). However, that work focused on fixed tube current scans and did not specifically address tube current modulation (TCM) scans, which are currently the majority of clinical scans performed. The purpose of this study was to extend the SSDE concept to account for TCM by investigating the feasibility of using anatomic and organ specific regions of scanner output to improve accuracy of dose estimates.

View Article and Find Full Text PDF

The cancer risk due to chronic transuranic intakes is properly calculated using an integration over multiple years of intake of the annual effective dose rates arising each year following an intake multiplied by age-dependent risk functions for the year during which the dose is actually received. Approximate computations of risk involving sums of the products of committed effective dose and the age-dependent risk functions for each year of intake indicate the appropriateness of the committed effective dose as a surrogate quantity for risk when applied to different circumstances. The assumptions that all dose is received at the time of intake with committed effective dose and that risk is uniform over a range of ages both lead to a misuse of the available age-dependent risk functions and thus contribute to a divergence from the true risk associated with an intake over multiple years.

View Article and Find Full Text PDF