Publications by authors named "Kyeongha Kwon"

Partial cystectomy procedures for urinary bladder-related dysfunction involve long recovery periods, during which urodynamic studies (UDS) intermittently assess lower urinary tract function. However, UDS are not patient-friendly, they exhibit user-to-user variability, and they amount to snapshots in time, limiting the ability to collect continuous, longitudinal data. These procedures also pose the risk of catheter-associated urinary tract infections, which can progress to ascending pyelonephritis due to prolonged lower tract manipulation in high-risk patients.

View Article and Find Full Text PDF

Despite the increasing number of stents implanted each year worldwide, patients remain at high risk for developing in-stent restenosis. Various self-reporting stents have been developed to address this challenge, but their practical utility has been limited by low sensitivity and limited data collection. Herein, we propose a next-generation self-reporting stent that can monitor blood pressure and blood flow inside the blood arteries.

View Article and Find Full Text PDF

Chronic wounds represent a major health risk for diabetic patients. Regeneration of such wounds requires regular medical treatments over periods that can extend for several months or more. Schemes for monitoring the healing process can provide important feedback to the patient and caregiver.

View Article and Find Full Text PDF

Fully implantable wireless systems for the recording and modulation of neural circuits that do not require physical tethers or batteries allow for studies that demand the use of unconstrained and freely behaving animals in isolation or in social groups. Moreover, feedback-control algorithms that can be executed within such devices without the need for remote computing eliminate virtual tethers and any associated latencies. Here we report a wireless and battery-less technology of this type, implanted subdermally along the back of freely moving small animals, for the autonomous recording of electroencephalograms, electromyograms and body temperature, and for closed-loop neuromodulation via optogenetics and pharmacology.

View Article and Find Full Text PDF

Devices for monitoring blood haemodynamics can guide the perioperative management of patients with cardiovascular disease. Current technologies for this purpose are constrained by wired connections to external electronics, and wireless alternatives are restricted to monitoring of either blood pressure or blood flow. Here we report the design aspects and performance parameters of an integrated wireless sensor capable of implantation in the heart or in a blood vessel for simultaneous measurements of pressure, flow rate and temperature in real time.

View Article and Find Full Text PDF
Article Synopsis
  • * Inflammation from these wounds disrupts natural electrical signals, which are crucial for the movement of skin cells necessary for healing; thus, electrical stimulation therapy is proposed as a potential treatment.
  • * A new wireless, battery-free, and bioresorbable electrotherapy device has been developed, successfully speeding up healing in diabetic mice by enhancing skin cell movement, reducing inflammation, and improving blood vessel formation while enabling monitoring of the healing process through impedance changes.
View Article and Find Full Text PDF

Accurate measurements of skin hydration are of great interest to dermatological science and clinical practice. This parameter serves as a relevant surrogate of skin barrier function, a key representative benchmark for overall skin health. The skin hydration sensor (SHS) is a soft, skin-interfaced wireless system that exploits a thermal measurement method, as an alternative to conventional impedance-based hand-held probes.

View Article and Find Full Text PDF

Swallowing is a complex neuromuscular activity regulated by the autonomic nervous system. Millions of adults suffer from dysphagia (impaired or difficulty swallowing), including patients with neurological disorders, head and neck cancer, gastrointestinal diseases, and respiratory disorders. Therapeutic treatments for dysphagia include interventions by speech-language pathologists designed to improve the physiology of the swallowing mechanism by training patients to initiate swallows with sufficient frequency and during the expiratory phase of the breathing cycle.

View Article and Find Full Text PDF

Capabilities for continuous monitoring of pressures and temperatures at critical skin interfaces can help to guide care strategies that minimize the potential for pressure injuries in hospitalized patients or in individuals confined to the bed. This paper introduces a soft, skin-mountable class of sensor system for this purpose. The design includes a pressure-responsive element based on membrane deflection and a battery-free, wireless mode of operation capable of multi-site measurements at strategic locations across the body.

View Article and Find Full Text PDF

Soft, skin-integrated electronic sensors can provide continuous measurements of diverse physiological parameters, with broad relevance to the future of human health care. Motion artifacts can, however, corrupt the recorded signals, particularly those associated with mechanical signatures of cardiopulmonary processes. Design strategies introduced here address this limitation through differential operation of a matched, time-synchronized pair of high-bandwidth accelerometers located on parts of the anatomy that exhibit strong spatial gradients in motion characteristics.

View Article and Find Full Text PDF

Background: Melanoma is attributable to predisposing phenotypical factors, such as skin that easily sunburns and unprotected exposure to carcinogenic UV radiation. Reducing the proportion of young adults who get sunburned may reduce the incidence of melanoma, a deadly form of skin cancer. Advances in technology have enabled the delivery of real-time UV light exposure and content-relevant health interventions.

View Article and Find Full Text PDF

Three-dimensional (3D), submillimeter-scale constructs of neural cells, known as cortical spheroids, are of rapidly growing importance in biological research because these systems reproduce complex features of the brain in vitro. Despite their great potential for studies of neurodevelopment and neurological disease modeling, 3D living objects cannot be studied easily using conventional approaches to neuromodulation, sensing, and manipulation. Here, we introduce classes of microfabricated 3D frameworks as compliant, multifunctional neural interfaces to spheroids and to assembloids.

View Article and Find Full Text PDF

Accurate, real-time monitoring of intravascular oxygen levels is important in tracking the cardiopulmonary health of patients after cardiothoracic surgery. Existing technologies use intravascular placement of glass fiber-optic catheters that pose risks of blood vessel damage, thrombosis, and infection. In addition, physical tethers to power supply systems and data acquisition hardware limit freedom of movement and add clutter to the intensive care unit.

View Article and Find Full Text PDF

Precise, quantitative measurements of the hydration status of skin can yield important insights into dermatological health and skin structure and function, with additional relevance to essential processes of thermoregulation and other features of basic physiology. Existing tools for determining skin water content exploit surrogate electrical assessments performed with bulky, rigid, and expensive instruments that are difficult to use in a repeatable manner. Recent alternatives exploit thermal measurements using soft wireless devices that adhere gently and noninvasively to the surface of the skin, but with limited operating range (∼1 cm) and high sensitivity to subtle environmental fluctuations.

View Article and Find Full Text PDF

Precise form-fitting of prosthetic sockets is important for the comfort and well-being of persons with limb amputations. Capabilities for continuous monitoring of pressure and temperature at the skin-prosthesis interface can be valuable in the fitting process and in monitoring for the development of dangerous regions of increased pressure and temperature as limb volume changes during daily activities. Conventional pressure transducers and temperature sensors cannot provide comfortable, irritation-free measurements because of their relatively rigid construction and requirements for wired interfaces to external data acquisition hardware.

View Article and Find Full Text PDF

Therapeutic compression garments (TCGs) are key tools for the management of a wide range of vascular lower extremity conditions. Proper use of TCGs involves application of a minimum and consistent pressure across the lower extremities for extended periods of time. Slight changes in the characteristics of the fabric and the mechanical properties of the tissues lead to requirements for frequent measurements and corresponding adjustments of the applied pressure.

View Article and Find Full Text PDF

Hydrocephalus is a common disorder caused by the buildup of cerebrospinal fluid (CSF) in the brain. Treatment typically involves the surgical implantation of a pressure-regulated silicone tube assembly, known as a shunt. Unfortunately, shunts have extremely high failure rates and diagnosing shunt malfunction is challenging due to a combination of vague symptoms and a lack of a convenient means to monitor flow.

View Article and Find Full Text PDF

Exposure to electromagnetic radiation (EMR) from the sun and from artificial lighting systems represents a modifiable risk factor for a broad range of health conditions including skin cancer, skin aging, sleep and mood disorders, and retinal damage. Technologies for personalized EMR dosimetry could guide lifestyles toward behaviors that ensure healthy levels of exposure. Here, we report a millimeter-scale, ultralow-power digital dosimeter platform that provides continuous EMR dosimetry in an autonomous mode at one or multiple wavelengths simultaneously, with time-managed wireless, long-range communication to standard consumer devices.

View Article and Find Full Text PDF
Article Synopsis
  • Researchers have developed a microelectromechanical sensor that mimics skin receptors, which could improve artificial interactions with the environment.
  • The sensor features monocrystalline silicon nanomembranes that measure various mechanical stimuli—like force and temperature—simultaneously and with high sensitivity.
  • This technology allows for quick response times and can be easily made in large quantities, with the added benefit of integrating wireless data capabilities for easy use with consumer devices.
View Article and Find Full Text PDF

This paper presents the first time-division-duplex transceiver IC for a 5-Fr 6-electrode renal denervation (RDN) catheter for treatment of resistant hypertension. Each IC encapsulated in a platinum electrode implements an RDN catheter with 37.5 % of diameter reduction, which enables minimally invasive surgery with reduced complications.

View Article and Find Full Text PDF