The over-growth of phytoplankton causes harmful algal blooms (HABs) in marine ecological environments. Mobility measurement is important in understanding the action of HABs. In this study, the mobility of Amphidinium carterae Hulburt (A.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
October 2016
The arterial structure cyclically fluctuates in three-dimensions (3-D) caused by pulsatile blood flow. The evaluation of arterial wall motion and hemodynamics contributes to early diagnosis of carotid atherosclerosis. Ultrasound is one of the most appropriate imaging modalities to evaluate arterial wall motion in real time.
View Article and Find Full Text PDFDespite considerable research efforts on the relationship between arterial geometry and cardiovascular pathology, information is lacking on the pulsatile geometrical variation caused by arterial distensibility and cardiomotility because of the lack of suitable in vivo experimental models and the methodological difficulties in examining the arterial dynamics. We aimed to investigate the feasibility of using a chick embryo system as an experimental model for basic research on the pulsatile variation of arterial geometry. Optical microscope video images of various arterial shapes in chick chorioallantoic circulation were recorded from different locations and different embryo samples.
View Article and Find Full Text PDFVisualizing and analyzing the morphological structure of carotid bifurcations are important for understanding the etiology of carotid atherosclerosis, which is a major cause of stroke and transient ischemic attack. For delineation of vasculatures in the carotid artery, ultrasound examinations have been widely employed because of a noninvasive procedure without ionizing radiation. However, conventional 2D ultrasound imaging has technical limitations in observing the complicated 3D shapes and asymmetric vasodilation of bifurcations.
View Article and Find Full Text PDFUltrasound speckle image of blood is mainly attributed by red blood cells (RBCs) which tend to form RBC aggregates. RBC aggregates are separated into individual cells when the shear force is over a certain value. The dissociation of RBC aggregates has an influence on the performance of ultrasound speckle image velocimetry (SIV) technique in which a cross-correlation algorithm is applied to the speckle images to get the velocity field information.
View Article and Find Full Text PDFThe "black hole," a hypo-echoic hole at the center of the bloodstream surrounded by a hyper-echoic zone in cross-sectional views, has been observed in ultrasound backscattering measurements of blood with red blood cell aggregation in in vitro studies. We investigated whether the phenomenon occurs in the in vivo arterial bloodstream of rats using a high-frequency ultrasound imaging system. Longitudinal and cross-sectional ultrasound images of the rat common carotid artery (CCA) and abdominal aorta were obtained using a 40-MHz ultrasound system.
View Article and Find Full Text PDFPrevious studies have found that ultrasound backscatter from blood in vascular flow systems varies under pulsatile flow, with the maximum values occurring during the systolic period. This phenomenon is of particular interest in hemorheology because it is contrary to the well-known fact that red blood cell (RBC) aggregation, which determines the intensity of ultrasound backscatter from blood, decreases at a high systolic shear rate. In the present study, a rat model was used to provide basic information on the characteristics of blood echogenicity in arterial blood flow to investigate the phenomenon of RBC aggregation under pulsatile flow.
View Article and Find Full Text PDFUltrasound-based techniques have been developed and widely used in noninvasive measurement of blood velocity. Speckle image velocimetry (SIV), which applies a cross-correlation algorithm to consecutive B-mode images of blood flow has often been employed owing to its better spatial resolution compared with conventional Doppler-based measurement techniques. The SIV technique utilizes speckles backscattered from red blood cell (RBC) aggregates as flow tracers.
View Article and Find Full Text PDFThe geometry of carotid artery bifurcation is of high clinical interest because it determines the characteristics of blood flow that is closely related to the formation and development of atherosclerotic plaque. However, information on the dynamic changes in the vessel wall of carotid artery bifurcation during a pulsatile cycle is limited. This pilot study investigated the cyclic changes in carotid artery geometry caused by blood flow pulsation in rats.
View Article and Find Full Text PDFMicrovasc Res
November 2012
The micro-particle tracking velocimetry (μ-PTV) technique is used to obtain the velocity fields of blood flow in the microvasculature under in vivo conditions because it can provide the blood velocity distribution in microvessels with high spatial resolution. The in vivo μ-PTV technique usually requires a few to tens of seconds to obtain a whole velocity profile across the vessel diameter because of the limited number density of tracer particles under in vivo conditions. Thus, the μ-PTV technique alone is limited in measuring unsteady blood flows that fluctuate irregularly due to the heart beating and muscle movement in surrounding tissues.
View Article and Find Full Text PDFMany studies have been performed to better understand the hemodynamics in microvessels, such as arterioles and venules. However, due to the heterogeneous features of size, shape, blood-flow velocity, and pulsatility of microvessels, conducting a systematic study on these factors has been almost impossible. Although in vitro studies have been performed for this purpose, the usefulness of in vitro data is limited by the fact that the rheological properties of blood are changed as blood is exposed to in vitro environments.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
December 2012
To measure instantaneous velocity fields of venous blood flow in a rat using X-ray particle tracking method. Gold nanoparticles (AuNPs) incorporated chitosan microparticles were applied as biocompatible flow tracers. After intravenous injection of the AuNP-chitosan particles into 7- to 9-week-old male rat vein, X-ray images of particle movement inside the cranial vena cava were consecutively captured.
View Article and Find Full Text PDFThis study aims to investigate the feasibility of using high-frequency ultrasound (HFUS) for simultaneous monitoring of blood coagulation and red blood cell (RBC) aggregation. Using a 35-MHz ultrasound scanner, ultrasound speckle data were acquired from whole blood samples of three experimental groups of rats, including 4,4'-diisothiocyanatostilbene-2,2'-disulfonic acid (DIDS)-treated, noncoagulation and normal control groups. The variations of blood echogenicity, the shape parameters of probability distribution of speckle intensity (skewness and kurtosis) and the correlation coefficient between two consecutive speckle data were calculated as a function of time starting from immediately after taking blood.
View Article and Find Full Text PDFLight reflectance of blood is a complex phenomenon affected by hematocrit and red blood cell (RBC) aggregation (rouleaux formation). According to the hypothesis that RBC rouleaux are aligned with the direction of blood flow, the spatial alignment of RBC rouleaux, as well as their size and quantity in the blood, may also affect light reflectance. The present study aims to investigate the effect of the spatial alignment and distribution of RBC rouleaux on light reflection using optical coherence tomography (OCT).
View Article and Find Full Text PDFCardiac outflow in the early developmental stage of a chick embryo is known to be highly variable depending on environmental temperature. To investigate the effects of environmental hypothermia on the blood flow in the outflow tract (OFT) of chick embryonic hearts, microscopic flow images were consecutively captured from chick embryos at HH stage 17 (2.5 days of incubation) at room temperature.
View Article and Find Full Text PDFIntroduction: Gemcitabine, the current standard of care for pancreatic ductal adenocarcinoma (PDA), has a less than 10% partial response rate. Genexol-PM, a modified form of paclitaxel, has been shown to have antitumour effects in clinical trials of metastatic breast and small-lung-cell carcinoma. The aim of the present study was to determine if Genexol would be a beneficial treatment for gemcitabine-resistant PDA.
View Article and Find Full Text PDFPerfluorocarbon nanoemulsions can deliver lipophilic therapeutic agents to solid tumors and simultaneously provide for monitoring nanocarrier biodistribution via ultrasonography and/or (19)F MRI. In the first generation of block copolymer stabilized perfluorocarbon nanoemulsions, perfluoropentane (PFP) was used as the droplet forming compound. Although manifesting excellent therapeutic and ultrasound imaging properties, PFP nanoemulsions were unstable at storage, difficult to handle, and underwent hard to control phenomenon of irreversible droplet-to-bubble transition upon injection.
View Article and Find Full Text PDFThis study aims to investigate the blood flow around the perivalvular area in a human superficial vein using high-frequency ultrasound (HFUS) speckle image velocimetry. HFUS B-mode images were captured from the superficial veins of human lower extremity with a 35-MHz transducer. To measure the instantaneous velocity fields of blood flow, a cross-correlation particle image velocimetry (PIV) algorithm was applied to two B-mode images that were captured consecutively.
View Article and Find Full Text PDFOpt Express
December 2010
When a coherent beam illuminates spatially disordered particles, speckle patterns are formed due to interference of the scattered light waves. Speckle patterns from biological tissues using synchrotron phase contrast X-ray imaging can provide functional information about micro-scale morphological structures of the tissues. In this study, we investigated the size and contrast variations of the speckles of aggregated red blood cells (RBCs) suspensions with varying the degree of RBC aggregation.
View Article and Find Full Text PDFHigh-frequency ultrasound (HFUS) signals backscattered from RBL-2H3 cell pellets prepared under different centrifugal forces were analyzed to investigate the packing effect of cell aggregates. The measurements were performed in a pulse-echo setup with a 40-MHz transducer. The changes of ultrasound signals from cell pellet in backscattered power, statistical parameter, and pellet thickness were monitored after centrifugation at between 100g and 1600g.
View Article and Find Full Text PDFTo better understand the characteristics of erythrocyte aggregation in flowing blood, echogenicity variation in blood was observed both in vitro and in vivo. However, few noninvasive observations of blood echogenicity variation during the cardiac cycle in human arteries have been reported. In the present study, to reduce the dynamic range between the blood vessel lumen and the surrounding tissue, coded harmonic images were acquired from human carotid arteries using a GE LOGIQ 700 Expert system (GE, Milwaukee, WI, USA) with an M12L probe, which enabled the noninvasive detection of the cyclic and radial variation of echogenicity in arterial vessels.
View Article and Find Full Text PDFCavitation properties of block copolymer stabilized perfluoropentane nanoemulsions have been investigated. The nanoemulsions were stabilized by two biodegradable amphiphilic block copolymers differing in the structure of the hydrophobic block, poly(ethylene oxide)-co-poly(L-lactide) (PEG-PLLA) and poly(ethylene oxide)-co-polycaprolactone (PEG-PCL). Cavitation parameters were measured in liquid emulsions and gels as a function of ultrasound pressure for unfocused or focused 1-MHz ultrasound.
View Article and Find Full Text PDFThe paper describes droplet-to-bubble transition in block copolymer stabilized perfluoropentane nanoemulsions. Three physical factors that trigger droplet-to-bubble transition in liquid emulsions and gels were evaluated, namely heat, ultrasound, and injections through fine-gauge needles. Among those listed, ultrasound irradiation was found the most efficient factor.
View Article and Find Full Text PDFPancreatic ductal adenocarcinoma (PDA) is the fourth most common cause of cancer death in the United States, with a median survival time of only 3-6 months for forty percent of patients. Current treatments are ineffective, and new PDA therapies are urgently needed. In this context, ultrasound-mediated chemotherapy by polymeric micelles and/or nanoemulsion/microbubble encapsulated drugs may offer an innovative approach to PDA treatment.
View Article and Find Full Text PDFThe paper reports the results of nanotherapy of ovarian, breast, and pancreatic cancerous tumors by paclitaxel-loaded nanoemulsions that convert into microbubbles locally in tumor tissue under the action of tumor-directed therapeutic ultrasound. Tumor accumulation of nanoemulsions was confirmed by ultrasound imaging. Dramatic regression of ovarian, breast, and orthotopic pancreatic tumors was observed in tumor therapy through systemic injections of drug-loaded nanoemulsions combined with therapeutic ultrasound, signifying efficient ultrasound-triggered drug release from tumor-accumulated nanodroplets.
View Article and Find Full Text PDF